Product Feature: Experience the exceptional efficiency of our Cooling Tower Cross Flow Fill, designed specifically with PVC materials, crafted to perfection with 950mm and 1270mm width options. These fills are engineered to optimize thermal performance, ensuring maximum cooling effectiveness for your systems.
Product Description
SHH Introducing the Newin SHH Series Cross Flow Film Fill – a marvel crafted for square cooling towers. Boasting advanced technology and an impressively extended lifespan, this product ensures minimal resistance while remaining astonishingly lightweight. With its sleek, smooth surface and robust pressure strength, it promises unwavering durability without compromising safety, being both non-toxic and non-irritating. Made from high-quality new PVC raw material, our film fill guarantees exceptional quality and long-lasting performance. Rigorous tests and production operations reveal its outstanding cooling effectiveness, making it the perfect choice for your cooling needs.
FEATURES
- Crafted from modified PVC sheets, this infill incorporates a unique formula that endows it with strong resistance and unparalleled durability, ensuring longevity and reliability.
- Featuring a vac form special processing design, the inner (fan side) edge is equipped with an integrated liquid baffle plate that minimizes water drift loss while maximizing the heat exchange efficiency between water and air.
- Designed to withstand standard heat temperatures of up to 50°C, with an optional heatproof specification available for usage up to 80°C, catering to a range of thermal demands.
PICTURE IN DETAIL

Parameter
PROPERTIES
No matter the specifications of SHH film fill you require—be it length, width, material, or thickness—please share your exact needs with us for the perfect solution and offer. At Newin, we are committed to meeting every customer requirement, offering fill media in either flame-retardant or anti-bacterial formulations upon request.
Module Length (Max) |
mm |
950 |
Module Width |
mm |
950/1270 |
Module Depth |
mm |
- |
Flute Height |
mm |
20 |
Flute Corrugation Angle |
degrees |
- |
Surface Area |
m2/m3 |
147 |
Sheet Thickness - Before Forming |
mm |
0.32 |
Sheet Thickness - After Forming |
mm |
0.28 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - High temp. |
°C |
80 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
Newin provides comprehensive structure and installation drawing advice, along with job site storage guidance and a quality control report with every shipment. This ensures our customers receive materials with the utmost attention to detail. Additionally, OEM services and bespoke mold designs are available to cater to special requests.
Application
APPLICATION & USAGE
The Newin SHH Film Fill is specifically designed for compatibility with the impressive Shinwa cooling tower series.
Model SNC-U, and SDC-U Field Erected systems.These systems are rigorously tested to SGS standards and comply with ASTM criteria, ensuring high-quality infill for optimal efficiency in cooling towers. Simply provide us with your tower model or dimensions, and we will expertly calculate the number of sheets necessary for replacing your cooling tower's components.
FILED DATA FOR CROSS FLOW FILM FILL REPLACEMENT
Please complete the measurements below for your maintenance or repair projects. When you demand quality and reliability, trust Newin for exceptional service. Whether it's a site visit or maintenance, our engineering prowess ensures a perfect fit for your cooling tower fills or components.
Options
Discover Other Exciting Opportunities:

NEWIN Manufacturing Base

NEWIN FACTORY
Embark on an awe-inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the dynamic industrial hub of Huizhou, Guangdong. Stretching over an expansive 10,000 square meters, this facility stands tall as a beacon of innovation, excellence, and cutting-edge technological advancements.
ISO CERTIFICATION
We proudly emphasize our unwavering commitment to unrivaled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for unmatched excellence.
WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Experience unparalleled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model showcases the pinnacle of cooling tower technology.
·
NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry benchmarks and consistently exceeding expectations for enduring excellence.
·
NTG Explore the extraordinary capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
·
NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
·
NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unparalleled results.
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a wide variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories designed for your cooling tower to achieve optimal performance.
CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping
Open type cooling towers shipment: Experience the epitome of security and precision with our meticulously coordinated transportation solutions for open-type cooling towers. Each tower is cocooned in top-tier materials and employs the latest packing innovations, guaranteeing their pristine arrival at your doorstep. Our unwavering commitment to safeguarding your investment ensures comprehensive protection against any potential transit hazards. Delight in the ease of our flawless logistics and swift delivery, meticulously orchestrated to bring your cooling solutions to life without delay.
Closed type cooling towers shipment: Bask in the confidence provided by our unparalleled packaging solutions, specifically tailored for closed-type cooling towers. Each unit is wrapped with exceptional care and resilience, equipped to withstand the most rigorous transit challenges, ensuring their immaculate arrival and readiness for immediate integration. Our unyielding dedication to excellence and rapid delivery empowers you to seamlessly embed our state-of-the-art cooling innovations into your operations, liberating you from any logistical concerns.
Technical Strength& Standards

Certifications