Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications

Product Details
Customization: Available
Ventilation Mode: Mechanical Ventilation
Material: Metal

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
  • Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
  • Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
  • Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
  • Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
  • Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Find Similar Products
  • Overview
  • Features
  • Working Principle
  • Parameter
  • Components& Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWFL-V
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
207~936kw
Transport Package
20/40/40hq Container
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000

Product Description

NEWIN High-Capacity Dry Air Cooler: Elevate Your Cooling Experience with Cutting-Edge Innovation. Discover unparalleled performance and efficiency with our advanced cooling solutions, designed to redefine comfort and reliability.


NWFL-V Introducing the NWFL-V series, a marvel in cooling technology with its sophisticated V type dry air cooler. Expertly crafted with a pioneering Free Cooling System, it redefines efficiency in cooling performance. Perfectly tailored for HVAC systems and a multitude of other facilities, this revolutionary equipment offers exceptional cooling capabilities while being environmentally conscious. Embrace superior cooling that not only meets but exceeds expectations, all while drastically minimizing water usage compared to conventional evaporative cooling techniques.
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Features
· Ingenious V-type design paired with a state-of-the-art Free Cooling System,
Delivering superior cooling efficiency while ingeniously eliminating water consumption.

· Incorporates optimally efficient components, such as the advanced EC motor,
Ensuring peak system efficiency along with outstanding energy savings.

· Designed with extensive redundancy,
Ensuring consistent performance by effectively eliminating any thermal performance loss.

· High reliability combined with effortless maintenance for ease of use.
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
 
Working Principle

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
When NWFL-V adiabatic cooler is in operation:
The NWFL-V adiabatic cooler showcases an innovative and superior EC fan system that meticulously draws in cool, dry air. This air is smoothly channeled into the cooling tower via the expertly crafted V-shaped finned tube heat exchanger. The unique V-shaped design significantly amplifies the cooling potential by maximizing the contact surface area, which greatly enhances the cooling performance for both the incoming air and the hot process fluid. This leads to a substantial increase in heat exchange efficiency. After this optimal heat transfer process has taken place with the cool dry air, the hot, saturated air is proficiently expelled from the tower. This results in exceptional Free Cooling, accomplished through advanced non-evaporative methods, ensuring a leap in cooling efficiency and effectiveness.

Series Type Capacity 1. Fan Drive System 2. Heat Exchange System
NWFL-V V Range EC axial fans Finned coil
Maximum thermal performance 207~936kw Intelligent frequency conversion, 
more energy saving
Maximum heat transfer surface
Free cooling 
system
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption.
Application Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc.
Parameter
 
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Model Cooling Capacity Total Dimension Fan Weight
L W H Nos of Fans Noise Level Power Shipping Operation
kw mm mm mm Nos dB(A) kw kg kg
NWFL-231-4D10-800V 200 2740 2050 2190 4 79.4 3.14  1187  1386 
NWFL-231-6D10-800V 250 2740 2050 2190 4 82.7 3.76  1332  1586 
NWFL-231-8D10-800V 290 2740 2050 2190 4 87.8 4.89  1477  1786 
NWFL-241-4D10-800V 255 2740 2050 2550 4 80 4.43  1329  1590 
NWFL-241-6D10-800V 315 2740 2050 2550 4 81.8 5.47  1522  1854 
NWFL-241-8D10-800V 360 2740 2050 2550 4 84.5 6.49  1714  2119 
NWFL-251-4D10-800V 310 2740 2050 2980 4 81.5 6.44  1493  1817 
NWFL-251-6D10-800V 400 2740 2050 2980 4 83 7.61  1732  2146 
NWFL-251-8D10-800V 450 2740 2050 2980 4 85 8.81  1971  2475 
NWFL-261-4D10-900V 375 2740 2250 3300 4 80.8 7.37  1675  2060 
NWFL-261-6D10-900V 470 2740 2250 3300 4 84.9 8.35  1961  2453 
NWFL-261-8D10-900V 535 2740 2250 3300 4 86.4 9.75  2247  2847 
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
· Heavy-duty Construction

Crafted with masterful precision, the galvanized steel panels of the NEWIN High-Capacity Air Cooler are fortified with the groundbreaking NEWIN Armour anti-corrosion coating. This innovative protective layer offers unparalleled resistance, rivaling the durability of stainless steel, enabling the equipment to operate at elevated concentration cycles. This not only extends the operational lifespan but also dramatically reduces water consumption. Furthermore, should the coating suffer minor damage, it is specially designed for easy repair, ensuring the cooler's long-lasting durability and reliability.
· V Type Finned Coil Heat Exchanger

Our meticulously engineered finned coil heat exchanger is crafted with high-quality copper tubes and strategically positioned aluminum fins, achieving optimal heat exchange performance. The copper tubes are precisely brazed to the coil headers and expertly flared to the finned coil, ensuring exceptional thermal conduction and maximum efficiency in heat transfer.
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
· EC Axial Fan

- The precision-crafted straight-shaft drive of our EC motor boasts a remarkable IP55 protection grade and F insulation grade. Designed for superior performance, it ensures seamless, long-term operation in demanding hot and humid environments, delivering outstanding energy efficiency that meets or exceeds the stringent IE4 standards.

- Our fans are equipped with robust tapered roller bearings, providing exceptional load-bearing capacity and an impressive service life exceeding 20,000 hours. This ensures consistent, unwavering performance and durability over time.

- Through rigorous static and dynamic testing, noise levels are meticulously minimized, maintaining exceptional heat exchange efficiency. Utilizing advanced PFC technology, harmonics are kept under 35%, ensuring the EC fan system maintains high static efficiency even at reduced speeds, delivering a harmonious blend of power and tranquility.
· Adiabatic Intelligent Controls

- Our EC fans are equipped with cutting-edge intelligent frequency conversion, dynamically adapting their functionality to meet varied operational demands, thereby optimizing energy savings.

- The system is engineered to ensure dry operation capabilities in situations where water usage is restricted, maintaining reliability under diverse conditions.
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications

 

· Options

- Enhance the coil's resistance to external factors, significantly boosting durability.
- Implement a robust coil freeze-up safeguard for assured operational integrity in colder environments.
- Opt for our low-noise upgrade to enjoy quieter operation without compromising on outstanding performance.
- Increase the degree of redundancy for enhanced reliability and operational assurance, ensuring seamless functionality under all conditions.
NEWIN Manufacturing Base

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
NEWIN FACTORY
Nestled within the vibrant heart of Huizhou, Guangdong, our expansive manufacturing base stretches across an impressive 10,000 square meters. This state-of-the-art facility is a cornerstone of innovation and a beacon of production excellence, setting the stage for groundbreaking achievements.

ISO CERTIFICATION
Newin proudly holds prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management. This underscores our unwavering commitment to superior quality and sustainable, eco-friendly practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Our Cutting-edge Closed Type Cooling Tower Series is meticulously engineered to deliver optimal performance, ensuring reliability and efficiency in every operation.
· NSH/ NST Our Highly efficient Open Type Cooling Tower Series is masterfully designed for diversified applications, offering flexibility and exceptional performance.
· NTG Our Robust Industrial Type Cooling Tower Series is specifically tailored to meet the demands of challenging environments, providing unparalleled durability and efficiency.
· NECN/NECH Our Sophisticated Evaporative Condenser systems are crafted to deliver superior cooling efficiency, setting new standards in the industry.
· NWFL Our Innovative Dry Air Cooler solutions offer high-capacity, energy-efficient performance, redefining cooling technology with their advanced design.

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
NEWIN offers a comprehensive inventory of premium cooling tower accessories, meticulously crafted to cater to maintenance and replacement demands across a variety of cooling tower sizes and types. Reach out to us to customize the precise cooling tower accessories that meet your specific needs.

CONTAIN:
· Our fan drive system components, including fan, fan stack, reducer, motor, and shaft, are expertly crafted to enhance functionality and ensure seamless operation.
· Our water distribution elements, such as nozzles and drift eliminators, are designed for optimal fluid management, ensuring efficiency and reliability.
· Our heat exchange components, including PVC infills and cooling coils, guarantee efficient thermal transfer and robust performance.
· Our additional accessories, including air inlet louvers and valves, are meticulously engineered for seamless integration and superior functionality.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Revel in the ultimate convenience of our expertly orchestrated shipping solutions, ensuring your advanced equipment experiences a flawless transit journey. We guarantee timely delivery, preserving the equipment's pristine condition and peak performance. Entrust our dedicated logistics team to manage each intricate detail, freeing you to concentrate on what truly matters.

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Closed Type Cooling Towers Shipment: Embrace the unmatched reassurance with the secure and proficient delivery of our Closed Type Cooling Towers. Our meticulous handling protocols are crafted to protect your valuable assets, guaranteeing they arrive safely at their destination. Enjoy peace of mind with our precision shipping solutions, protecting your investments throughout their seamless journey.
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Technical Strength& Standards

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications
Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications

Certifications

Newin High-Capacity Air Cooler for Industrial Cooling Tower ApplicationsNewin High-Capacity Air Cooler for Industrial Cooling Tower ApplicationsNewin High-Capacity Air Cooler for Industrial Cooling Tower ApplicationsNewin High-Capacity Air Cooler for Industrial Cooling Tower Applications

Newin High-Capacity Air Cooler for Industrial Cooling Tower Applications

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More