Innovative Dry Air Cooler System for Effective Cooling Solutions

Product Details
Customization: Available
Ventilation Mode: Mechanical Ventilation
Material: Metal

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Innovative Dry Air Cooler System for Effective Cooling Solutions
  • Innovative Dry Air Cooler System for Effective Cooling Solutions
  • Innovative Dry Air Cooler System for Effective Cooling Solutions
  • Innovative Dry Air Cooler System for Effective Cooling Solutions
  • Innovative Dry Air Cooler System for Effective Cooling Solutions
  • Innovative Dry Air Cooler System for Effective Cooling Solutions
Find Similar Products
  • Overview
  • Features
  • Working Principle
  • Parameter
  • Components& Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWFL-V
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
207~936kw
Transport Package
20/40/40hq Container
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000

Product Description

Introducing the High-Capacity Dry Air Cooler, a hallmark of cutting-edge technology for Innovative Cooling Solutions. Experience the pinnacle of efficiency and reliability with our advanced system, designed to meet all your cooling needs with precision.


NWFL-V Discover the NWFL-V series, a V-type dry air cooler meticulously engineered with a state-of-the-art Free Cooling System. This series represents the epitome of efficient cooling, making it an ideal choice for HVAC systems and a wide range of other facilities. Enjoy the benefits of a cooling solution that eliminates water consumption, offering a sustainable alternative to traditional evaporative cooling methods.

Innovative Dry Air Cooler System for Effective Cooling Solutions
Features
· Ingeniously engineered with a V-type design coupled with a Free Cooling System,
Experience unparalleled cooling efficiency without a drop of water consumption.

· Equipped with premium, optimally efficient components, such as the state-of-the-art EC motor,
Ensures peak system performance while maximizing energy savings.

· Boasting substantial redundancy,
This innovation effectively eliminates any loss in thermal performance.

· Crafted for high reliability and designed for seamless maintenance with ease.
Innovative Dry Air Cooler System for Effective Cooling Solutions
 
Working Principle

Innovative Dry Air Cooler System for Effective Cooling Solutions
When NWFL-V adiabatic cooler is in operation:
The EC fan system expertly channels the refreshing cool dry air, guiding it into the tower through an ingeniously designed V-shaped finned tube heat exchanger. This innovative V-shape not only expands the surface contact area, but also turbocharges the cooling process for both air and the hot process fluid. The outcome? An impressive leap in heat exchange efficiency! Once the hot air completes its extensive journey of partition wall heat exchange with the revitalizing cool dry air, it is efficiently expelled as hot saturated air, out of the tower, culminating in a powerful and effective Free Cooling experience (employing a non-evaporative cooling method).

Series Type Capacity 1. Fan Drive System 2. Heat Exchange System
NWFL-V V Range EC axial fans Finned coil
Maximum thermal performance 207~936kw Intelligent frequency conversion, 
more energy saving
Maximum heat transfer surface
Free cooling 
system
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption.
Application Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc.
Parameter
 
Innovative Dry Air Cooler System for Effective Cooling Solutions
Model Cooling Capacity Total Dimension Fan Weight
L W H Nos of Fans Noise Level Power Shipping Operation
kw mm mm mm Nos dB(A) kw kg kg
NWFL-231-4D10-800V 200 2740 2050 2190 4 79.4 3.14  1187  1386 
NWFL-231-6D10-800V 250 2740 2050 2190 4 82.7 3.76  1332  1586 
NWFL-231-8D10-800V 290 2740 2050 2190 4 87.8 4.89  1477  1786 
NWFL-241-4D10-800V 255 2740 2050 2550 4 80 4.43  1329  1590 
NWFL-241-6D10-800V 315 2740 2050 2550 4 81.8 5.47  1522  1854 
NWFL-241-8D10-800V 360 2740 2050 2550 4 84.5 6.49  1714  2119 
NWFL-251-4D10-800V 310 2740 2050 2980 4 81.5 6.44  1493  1817 
NWFL-251-6D10-800V 400 2740 2050 2980 4 83 7.61  1732  2146 
NWFL-251-8D10-800V 450 2740 2050 2980 4 85 8.81  1971  2475 
NWFL-261-4D10-900V 375 2740 2250 3300 4 80.8 7.37  1675  2060 
NWFL-261-6D10-900V 470 2740 2250 3300 4 84.9 8.35  1961  2453 
NWFL-261-8D10-900V 535 2740 2250 3300 4 86.4 9.75  2247  2847 
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
Innovative Dry Air Cooler System for Effective Cooling Solutions
· Heavy-duty Construction

Crafted with precision, the galvanized steel panel featuring NEWIN Armour's anti-corrosion coating showcases unparalleled resilience and resistance akin to stainless steel. This design allows the equipment to operate efficiently with higher concentration cycles, significantly reducing water consumption. Should any damage occur, the coating's reparability ensures lasting protection and durability.
 
· V Type Finned Coil Heat Exchanger

Engineered with precision, the finned coil heat exchanger utilizes copper tubes paired with aluminum fins, expertly spaced to optimize heat exchange performance. The copper tubes are meticulously connected to the coil headers through brazing and to the finned coil by flaring, ensuring seamless thermal conduction and maximum efficiency.
Innovative Dry Air Cooler System for Effective Cooling Solutions
 
Innovative Dry Air Cooler System for Effective Cooling Solutions
· EC Axial Fan

- Our EC motor features a straight-shaft drive with an IP55 protection grade and F insulation grade, making it ideal for long-term operation in challenging hot and humid conditions. It delivers smooth operation and remarkable energy efficiency, meeting or exceeding the IE4 standards.

- Equipped with durable tapered roller bearings, our fans deliver excellent load-bearing capacity and an impressive service life that exceeds 20,000 hours, ensuring consistent high performance and longevity.

- Through meticulous static and dynamic testing, noise levels are minimized while superior heat exchange performance is maintained. With PFC technology in place, harmonics remain below 35%, ensuring the EC fan system achieves high static efficiency even at reduced speeds.
 
· Adiabatic Intelligent Controls

- EC fans feature intelligent frequency conversion catering to various on-site conditions, optimizing energy savings.

- Operates with dry force unit when water use is restricted, maintaining performance.
Innovative Dry Air Cooler System for Effective Cooling Solutions

 

· Options

- Enhance coil's resistance capabilities
- Integrated coil freeze-up protection
- Upgrade to low noise operation
- Amplify redundancy levels
NEWIN Manufacturing Base

Innovative Dry Air Cooler System for Effective Cooling Solutions
NEWIN FACTORY
Nestled in the heart of Huizhou, Guangdong, our sprawling manufacturing base covers an impressive 10,000 square meters. This state-of-the-art facility is designed for fostering innovation and achieving production excellence, setting the stage for groundbreaking developments.

ISO CERTIFICATION
Proudly adorned with prestigious ISO certifications, including ISO9001:2015 for impeccable Quality Management and ISO14001:2015 for outstanding Environmental Management, Newin stands as a beacon of commitment to unmatched quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Innovative Dry Air Cooler System for Effective Cooling Solutions
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Our groundbreaking Closed Type Cooling Tower Series is engineered to deliver peak performance, pushing the boundaries of efficiency and reliability.
· NSH/ NST The highly efficient Open Type Cooling Tower Series is expertly designed for a wide array of applications, ensuring versatile and adaptable cooling solutions.
· NTG The robust Industrial Type Cooling Tower Series is specifically engineered to withstand the challenges of demanding environments, providing unparalleled durability and performance.
· NECN/NECH Our sophisticated Evaporative Condenser systems are crafted to deliver unmatched cooling efficiency, setting new standards in the industry.
· NWFL Experience innovation with our Dry Air Cooler solutions, offering high-capacity and energy-efficient performance that meets the demands of modern cooling challenges.

Innovative Dry Air Cooler System for Effective Cooling Solutions
NEWIN offers a comprehensive selection of top-tier cooling tower accessories, adept at meeting maintenance and replacement needs for diverse cooling tower sizes and types. Connect with us to customize the cooling tower accessories tailored to your specific requirements.

CONTAIN:
· Fan drive system components, including fan, fan stack, reducer, motor, and shaft, expertly crafted to elevate functionality and performance.
· Water distribution elements, such as nozzles and drift eliminators, meticulously designed for superior fluid management and efficiency.
· Heat exchange components, like PVC infills and cooling coils, ensuring maximum thermal transfer and operational efficiency.
· Additional accessories, including air inlet louvers and valves, engineered with precision for seamless and effective integration.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Revel in a flawless logistics experience with our adeptly managed shipping solutions, guaranteeing your equipment's timely arrival in impeccable condition, ready to serve your cooling needs efficiently.

Innovative Dry Air Cooler System for Effective Cooling Solutions
Closed Type Cooling Towers Shipment: Gain peace of mind with our exceptional delivery service, designed to protect your crucial assets every step of the way, ensuring they reach their destination securely and promptly.
Innovative Dry Air Cooler System for Effective Cooling Solutions
Innovative Dry Air Cooler System for Effective Cooling Solutions
Technical Strength& Standards

Innovative Dry Air Cooler System for Effective Cooling Solutions
Innovative Dry Air Cooler System for Effective Cooling Solutions

Certifications

Innovative Dry Air Cooler System for Effective Cooling SolutionsInnovative Dry Air Cooler System for Effective Cooling SolutionsInnovative Dry Air Cooler System for Effective Cooling SolutionsInnovative Dry Air Cooler System for Effective Cooling Solutions

Innovative Dry Air Cooler System for Effective Cooling Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More