Optimal Cooling Padding for Efficient Crossflow Cooling Solutions

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
  • Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
  • Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
  • Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
  • Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
  • Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
BAH
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC/PP
Color
Black
Module Height
Customization
Module Width
1330mm
Flute Height
19mm
Service Life
More Than 20 Years
Installation
Hand up/Glued Into Blocks
Transport Package
Woodencase 20gp/40gp Container
Specification
900mmx450mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

Experience the unparalleled prowess of Newin's BAH Cooling Tower Fills, designed to unleash an extraordinary level of heat exchange efficiency. Elevate your cooling systems to new heights with our cutting-edge technology that promises exceptional performance. Discover the perfect blend of innovation and reliability, ensuring unmatched heat dissipation to optimize your crossflow cooling solutions effortlessly.
Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Product Description

BAH Experience the pinnacle of cooling technology with Newin's BAH Film Fill, a state-of-the-art hanging film cooling tower fill. Ingeniously designed, it features an exceptionally efficient cellular drift eliminator seamlessly integrated with a molded air inlet louver. This innovation masterfully spreads water into a delicate film across expansive vertical surfaces, ensuring unparalleled exposure to air flow for superior cooling efficiency. In comparison to traditional splash type fills, our BAH Film Fill offers significantly more water surface exposure per cubic foot. Certified by SGS tests adhering to ASTM Standards, it promises top-tier infill quality for optimal performance of your cooling tower. Choose between hanging or glue assembly methods, and enjoy peace of mind with our flame-resistant PVC material that is rated for flame spread and is self-extinguishing.


Pictures in Details

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Parameter
Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
 
 Module Length (Max)  mm Depend on customer demand
 Module Width   mm 1330
 Flute Height  mm 19
 Sheet Thickness - Before Forming  mm 0.38
 Sheet Thickness - After  Forming  mm 0.35
 Max. application temp. (short time) - PVC  °C 60
 Max.operating temp. (short time) - High temp.  °C 80
 Customized thickness available for special request. Contact Newin for details!

For any specialized requirements in BAH film fill, whether it be dimensions such as length and width, material composition, or thickness, kindly provide us with your detailed specifications. This will ensure we deliver the most accurate solution and competitive offer tailored to your needs. At Newin (Guangdong) Machinery Co., Ltd., we excel in accommodating all customer requirements. Additionally, we offer fill media with flame-retardant and anti-bacterial properties upon request, ensuring safety and hygiene in your cooling processes.
 

Field Data for Cross Flow Film Fill Replacement
Please fill in the measurement data below for your cooling tower maintenance or repair projects. When you demand exceptional quality and reliability, trust Newin. We provide comprehensive site visits and maintenance services, expertly engineered to seamlessly integrate with your cooling tower fills or components, ensuring optimal performance and longevity.

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Options

You may also be interested in exploring the following related products that perfectly complement and enhance the exceptional capabilities of our offerings:

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Optimal Cooling Padding for Efficient Crossflow Cooling Solutions

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
NEWIN Manufacturing Base

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
NEWIN FACTORY
Embark on a journey to our state-of-the-art manufacturing base, nestled in the thriving industrial hub of Huizhou, Guangdong. Spanning an expansive 10,000 square meters, our facility stands as a beacon of innovation and excellence, setting new benchmarks in the industry.

ISO CERTIFICATION
Our unwavering commitment to unparalleled quality and environmental stewardship is proudly underscored by our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification. These accolades affirm our dedication to excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience the unrivaled efficiency of our Closed Type Cooling Tower Series, meticulously designed for superior performance and reliability.
· NSH/ NST Discover unmatched reliability with our Open Type Cooling Tower Series, precisely engineered for optimal operation and longevity.
· NTG Explore the robust and versatile capabilities of our Industrial Type Cooling Tower Series, expertly crafted for heavy-duty applications and enduring performance.
· NECN/NECH Seamlessly integrate peak efficiency with our cutting-edge Evaporative Condenser models, designed for exceptional performance and reliability.
· NWFL Harness the power of advanced technology with our Dry Air Cooler, engineered for optimal air flow and superior cooling efficiency.

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
NEWIN is your trusted partner in cooling tower solutions, offering a comprehensive range of accessories to fulfill your maintenance and replacement needs across a diverse array of cooling tower sizes and types. Contact us to tailor the perfect accessory suite for your specific cooling tower requirements.

CONTAIN:
· A robust Fan drive system, including fan, fan stack, reducer, motor, and shaft, ensuring optimal performance and durability.
· Efficient Water distribution components, featuring precision-engineered nozzles and drift eliminators for maximum efficiency.
· Premium Heat exchange options, with high-quality PVC infills and cooling coils, designed for superior heat transfer.
· Additional essential accessories, such as expertly crafted air inlet louvers and valves, to complete your comprehensive cooling system.
 
Packaging & Shipping

Open type cooling towers shipment: At Newin (Guangdong) Machinery Co., Ltd., our open-type cooling towers are a testament to our commitment to excellence. Each unit is masterfully packaged with precision, securing it against any potential transit mishaps. Our use of superior-grade materials and innovative packing strategies ensures your cooling tower arrives in immaculate condition. Enjoy the assurance of seamless logistics and on-time delivery, allowing your cooling solutions to be up and running without any interruptions.

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Closed type cooling towers shipment: Discover unparalleled peace of mind with our comprehensive packaging solutions tailored for closed-type cooling towers. At Newin (Guangdong) Machinery Co., Ltd., we meticulously encase each tower to endure the challenges of transit, ensuring they reach you in pristine condition, ready to deliver exceptional performance. Our unwavering commitment to rigorous quality control and prompt shipping provides you the freedom to concentrate on maximizing the benefits of our cutting-edge cooling technology for your specific needs.
Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Technical Strength& Standards

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions
Optimal Cooling Padding for Efficient Crossflow Cooling Solutions

Certifications

Optimal Cooling Padding for Efficient Crossflow Cooling SolutionsOptimal Cooling Padding for Efficient Crossflow Cooling SolutionsOptimal Cooling Padding for Efficient Crossflow Cooling SolutionsOptimal Cooling Padding for Efficient Crossflow Cooling Solutions

Optimal Cooling Padding for Efficient Crossflow Cooling Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier