Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
  • Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
  • Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
  • Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
  • Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
  • Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
Find Similar Products
  • Overview
  • Parameter
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Condition
New
Ventilation Mode
Natural Ventilation
Material
Metal
Air Contact Form
Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Transport Package
Wooden Box
Specification
Customized
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000

Product Description

Overview

Crafted with precision, our Industrial Gear Reducers are expertly engineered to serve the demanding needs of cooling towers in expansive industrial facilities and power plants. With a design that transcends standard specifications, these reducers are meticulously crafted to enhance airflow through the tower while significantly reducing maintenance demands, ensuring both efficiency and reliability.


Gearbox Reducer

Our gear reducer for second gear transmission is a marvel of mechanical engineering, boasting a cutting-edge combination of spiral bevel and helical gear systems. Featuring a compact structure, it delivers impressive power transmission, smooth operations, and minimal noise. The gears are crafted from robust 20CrMnTi material, undergoing heat treatment to achieve exceptional wear and impact resistance. The advanced lubrication system cleverly marries oil immersion with splash flow, keeping the gears well-oiled. A sophisticated skeleton oil seal or mechanical seal enhances the high-speed shaft entrance. After an impressive 8000 hours of operation, the reducer cover should be removed to inspect seal wear, safeguarding continued optimal performance.

Designed with user-ease in mind, the lifting ring screw atop the gearbox is engineered for lid removal during maintenance, not for lifting the gearbox itself. Strategically placed control instrument contact screw holes on the box body allow seamless integration with control devices, tailored to user specifications.

 
Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
The dedicated cooling tower reducer primarily integrates a vertical shaft gear transmission system, seamlessly incorporating other transmission types to enhance versatility. Our esteemed product line features the M series and H series, each tailored to meet specialized industrial requirements.




Design Features:
· Meticulously engineered, each design is based on precise fan performance parameters and stringent requirements, ensuring optimal performance.
· Boasting an extraordinary service lifespan of 100,000 hours with a robust service factor KA=2, our gear reducers promise enduring reliability.
· Comprehensive strength calculations and component verifications are conducted for gears, shafts, and keys, ensuring unfailing load-bearing capacity and longevity.
· Our innovative lubrication system combines splash and self-lubrication for continuous, low-maintenance operation.
· Our helical gears adhere to the rigorous GB/T 3480 "Strength Calculation of Involute Gears", while spiral bevel gears meet the standards of GB/T 10062 for load-capacity calculations, guaranteeing uncompromised performance.
· A modular design featuring diverse materials and standardized components, allowing customization to meet any client requirement with precision.
· For extreme conditions, our optional forced cooling system ensures precise oil temperature control, safeguarding against overheating and maintaining peak performance.
Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
 
Parameter

Reducer Technical Parameter

No. Model Nominal RPM Ratio Input RPM Power(kw)
1 MSRD235 300 4.91 1480 45
220 4.42 980 30
200 4.91 980 30
2 MSRL200
(MSRL200A)
265 5.6 1480 45
238 6.21 1480 45
200 4.77 980 30
210 4.62 980 30
191 5.08 980 30
173 5.6 980 30
156 6.21 980 30
3 MSRL250
(MSRL250A)
165 8.97 1480 55
191 7.75 1480 55
214 6.91 1480 55
230 6.46 1480 55
251 5.89 1480 55
108 8.97 980 37
125 7.75 980 37
140 6.91 980 37
150 6.46 980 37
165 5.89 980 37
4 MSRL300
(MSRL300A)
136 10.83 1480 160
145 10.13 1480 160
155 9.5 1480 160
184 8.04 1480 160
90 10.83 980 90
97 10.13 980 90
101 9.5 980 90
122 8.04 980 90
5 MSRL350A 127 11.63 1480 160
136 10.95 1480 160
145 10.23 1480 160
155 9.68 1480 160
180 5.51 980 160
6 MSRL350D 105 14.11 1480 200
117 12.52 1480 200
127 11.55 1480 200
7 MSRL400 101 14.63 1480 220
107 13.86 1480 250
116 12.78 1480 250
8 HSRL350 101 14.63 1480 185
107 13.86 1480 185
117 12.67 1480 200
127 11.75 1480 200
136 10.83 1480 200
9 HSRL400 101 14.63 1480 220
107 13.86 1480 250
116 12.78 1480 250
10 HSRL400T 118 12.59 1480 200
Note:
1. Please be aware that the tables showcase a selection of our standard models. We offer a comprehensive range of tailored solutions to meet your specific needs.
2. These parameters serve as a preliminary guide only. For authoritative and precise specifications, kindly consult the official data sheets released by our technical department.
NEWIN Manufacturing Base

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
NEWIN FACTORY
Our expansive manufacturing base is strategically situated in the vibrant city of Huizhou, Guangdong, enveloping a sprawling area of 10,000 square meters, dedicated to innovation and precision.

ISO CERTIFICATION
We are proud holders of the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, underscoring our commitment to quality and sustainability.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Our innovative Closed Type Cooling Tower Series, designed to maximize efficiency and durability.
· NSH/ NST The versatile Open Type Cooling Tower Series, engineered for performance across various environments.
· NTG Robust and reliable Industrial Type Cooling Tower Series, perfect for demanding applications.
· NECN/NECH High-efficiency Evaporative condenser, optimizing cooling processes with precision.
· NWFL Advanced Dry Air Cooler, delivering exceptional dry cooling capabilities.

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
At NEWIN, we pride ourselves on manufacturing and maintaining a comprehensive inventory of essential cooling tower accessories, crafted to impeccably cater to maintenance and replacement needs across a diverse range of sizes and types. Contact us to explore bespoke accessory customization tailored to your specific cooling tower requirements.

CONTAIN:
· Fan drive system (including fan, fan stack, reducer, motor, shaft, and more)
· Water distribution (featuring nozzles, drift eliminator, and more)
· Heat exchange (with PVC infills, cooling coil, and others)
· Other accessories (such as air inlet louver, valve, etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Discover the unparalleled precision and expertise with which we handle the shipment of our open type cooling towers. Every unit is meticulously prepared and expertly transported, guaranteeing it reaches your destination in immaculate condition, primed for flawless installation and operation.

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
Closed Type Cooling Towers Shipment: Rely on our expertly coordinated shipping service for closed type cooling towers. Our meticulous process ensures your products are handled with utmost care and delivered with impeccable timing. Rest assured, they will arrive ready for immediate deployment, perfectly aligning with your operational requirements.

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
Technical Strength& Standards

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions
Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions

Certifications

Advanced Gear Reducer for Efficient Cooling Tower Ventilation SolutionsAdvanced Gear Reducer for Efficient Cooling Tower Ventilation SolutionsAdvanced Gear Reducer for Efficient Cooling Tower Ventilation SolutionsAdvanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions

Advanced Gear Reducer for Efficient Cooling Tower Ventilation Solutions


 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More