Lose Noise Nsh Counter Flow Cooling Tower/ Industrial Usage Cooling Tower
NEWIN NSH series F.R.P Counter Flow Square Type Cooling Tower
Features
♦ High efficiency, save energy to the largest extent
♦ Fit with various environment changes in different indutries
♦ Matched equipment running normaly
♦ Completely comply with national standards
Components Instruction
CASING AND WATER BASIN
Fiberglass reinforced polyester (FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed.
FAN & DRIVING SYSTEM
All cooling tower fans with adjustable pitch blades are applied to being balanced, it operates stably and quietly. Material chosen are A.B.S, aluminum alloy for normal standard, F.R.P or stainless steel material available for option.Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer or Gear box.
DISTRIBUTION SYSTEM
Using high coefficient rotating sprinkler head made of plastic or aluminum alloy could reduce the pressure of friction loss, and the water can be distributed evenly to achieve the max thermal cooling performance.
FILL PACKING
Used high quality & improved performance PVC with good material, it is high cooling efficiency and anti-corrosive & UL V-0. The surface of infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality. Special material for option if high entering water temperature.
FRAMEWORK
The framework is made of hot dip galvanized steel (HDGS), to makes the cooling tower in rust-free, durable and long service life.
Optional Accessories
♦ Noise reduction upgrade ♦ Anti-Freeze heater
♦ Vibration isolator & rubber mat ♦ Stainless steel framework / bolts and nuts (304 / 316)
♦ High-temperature upgrade ♦ Dual-speed Motor & VFD motorAnti-Freeze heater
Technical Specification of NSH Series Cooling Tower
Model |
Cooling Capacity
(RT) |
Motor
kw |
Fan Diameter
mm |
Dimension (mm) |
Water Inlet
DN |
Water Outlet
DN |
Weight (kg) |
H |
W |
L |
Dry |
Wet |
NSH-88-A16-319-C1 |
100 |
1600 |
3 |
2000 |
2000 |
3600 |
150 |
150 |
1150 |
2370 |
NSH-99-B18-319-C1 |
150 |
1800 |
4 |
2250 |
2250 |
3650 |
150 |
150 |
1250 |
2550 |
NSH-1010-B22-319-C1 |
175 |
2200 |
4 |
2500 |
2500 |
3700 |
150 |
150 |
1450 |
2980 |
NSH-1111-C22-319-C1 |
200 |
2200 |
5.5 |
2750 |
2750 |
3800 |
150 |
150 |
1620 |
3300 |
NSH-1212-C24-319-C1 |
250 |
2400 |
5.5 |
3000 |
3000 |
4100 |
200 |
200 |
1800 |
4690 |
NSH-1313-D24-319-C1 |
300 |
2400 |
7.5 |
3250 |
3250 |
4350 |
200 |
200 |
1950 |
4515 |
NSH-1414-D28-319-C1 |
400 |
2800 |
7.5 |
3500 |
3500 |
4350 |
200 |
200 |
2350 |
5685 |
NSH-1515-E28-319-C1 |
450 |
2800 |
11 |
3750 |
3750 |
4750 |
250 |
250 |
2820 |
6450 |
NSH-1616-E34-319-C1 |
500 |
3400 |
11 |
4000 |
4000 |
4800 |
250 |
250 |
3150 |
6990 |
NSH-1818-F34-319-C1 |
600 |
3400 |
15 |
4500 |
4500 |
5250 |
300 |
300 |
3720 |
8250 |
NSH-2020-F34-319-C1 |
700 |
3400 |
15 |
5000 |
5000 |
5400 |
300 |
300 |
3950 |
8480 |
NSH-2020-F38-319-C1 |
800 |
3800 |
15 |
5000 |
5000 |
5400 |
300 |
300 |
4350 |
9580 |
NSH-2121-F38-319-C1 |
900 |
3800 |
18.5 |
5250 |
5250 |
5700 |
350 |
350 |
4880 |
10620 |
NSH-2222-H42-319-C1 |
1000 |
4200 |
22 |
5500 |
5500 |
5900 |
350 |
350 |
5660 |
11780 |
NSH-2424-I42-319-C1 |
1200 |
4200 |
30 |
6000 |
6000 |
6550 |
400 |
400 |
6720 |
13700 |
NSH-2626-I47-319-C1 |
1300 |
4700 |
30 |
6500 |
6500 |
6550 |
400 |
400 |
7750 |
15670 |
NSH-2828-I47-319-C1 |
1500 |
4700 |
30 |
7000 |
7000 |
6950 |
450 |
450 |
8400 |
17270 |
Explore Our NSH Series FRP Cooling Tower Solutions: Tailored to Adapt Seamlessly to Varied Working Conditions with Versatile Upgraded Options.
Innovative Sewage Cooling Solutions
Advanced Heat Exchange Technology: Featuring NTF Non-Clogging Trickle Splash Fill for Superior Heat Transfer Efficiency
Robust Structure Design: Engineered with Full FRP Anti-Corrosion Structure for Longevity and Reliability
> Discover the NSH Series Full FRP Cooling Tower: NEWIN's Premier Cooling Solution for Sewage Projects in Indonesia.
Compact and Efficient Cooling Solution for Limited Spaces
Our Enhanced Design Boasts Dual Air Inlets, Perfect for Close Installation of Multiple Towers in Tight Spaces, Ensuring Optimal Cooling Performance.
> Tailored NSH Series Cooling Tower: NEWIN's Custom Solution for the ST Microelectronics Project in the Philippines.
Transformative Reconstruction for Old Wood Towers
Upgrade to a Next-Level Cooling Tower with a Robust and Durable Full FRP Structure, Offering a Service Life of Up to 30 Years with Enhanced Corrosion Resistance.
> Industrial-Grade NSH-FRP Series: NEWIN's Cutting-Edge Cooling Solution for the Chemical Fiber Factory in Singapore.
OPTIONS
State-of-the-Art Permanent Magnetic Direct-Driven Fan System
Strategically Engineered Energy Saving Design
> Utilize Variable Frequency Control for Low-Speed Operation, Boosting Efficiency and High Power Factor.
> Experience the Efficiency of a Direct-Driven Fan: No Transmission Losses, Maintenance-Free Operation.
> Achieve an IE5 Energy Efficiency Rating: Exceptional Power and Energy Savings Redefined.
NWN-Armour: The Pinnacle of Corrosion Resistant Technology
Innovative Corrosion Resistant Design
Galvanized Steel Panels Enhanced with NWN-Armour Anti-Corrosion Coating, Providing a Cost-Effective Alternative to Stainless Steel, Matching Its Corrosive Resilience.
Comprehensive Additional Accessories
Equip with Advanced PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction for Enhanced Performance and Efficiency.
NEWIN Manufacturing Base
Discover Our Advanced NEWIN FACTORY
Our state-of-the-art manufacturing base is strategically located in the vibrant city of Huizhou, Guangdong, sprawling across an impressive 10,000 square meters of excellence.
Prestigious ISO CERTIFICATION
Proud holders of ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, demonstrating our commitment to excellence and sustainability.
Explore Our Specialized WORKSHOPS
Precision and Expertise in Our Welding Workshop
Innovation at Its Best in the Filler Thermoforming Workshop
Unmatched Craftsmanship in the Sheet Metal Processing Workshop
Excellence in Assembly at the Cooling Tower Assembly Workshop
Comprehensive TESTING Facilities
Our cutting-edge Independent Testing LAB ensures top-notch quality and performance.
NEWIN COOLING TOWERS: Unparalleled Options
·
Series: NWN/ NWF/ NCFN Discover Our Closed Type Cooling Tower Series
·
Series: NSH/ NST Explore Our Open Type Cooling Tower Series
·
Series: NTG Industrial Type Cooling Tower Series for Heavy-Duty Applications
·
Models: NECN/NECH Efficient and Reliable Evaporative Condenser Solutions
·
Model: NWFL Cutting-edge Dry Air Cooler Systems
NEWIN is your go-to for high-quality cooling tower accessories. We stock an extensive range to fit almost any size and type of cooling tower, and our experts are ready to help you customize the perfect solutions for your specific maintenance and replacement needs. Contact us today!
CONTAIN: Essential Components
· Comprehensive Fan drive system (including fan, fan stack, reducer, motor, shaft, etc.)
· Efficient Water distribution systems (featuring nozzles, drift eliminator, etc.)
· Advanced Heat exchange solutions (with PVC infills, cooling coil, etc.)
· Versatile Other accessories (such as air inlet louver, valve, etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: At Newin (Guangdong) Machinery Co., Ltd., our open type cooling towers are meticulously packaged and shipped with the utmost care. We ensure that each component is securely packed to withstand the rigors of transportation, providing you with peace of mind that your order will arrive in pristine condition. Experience seamless delivery with robust packaging designed to protect your investment for years to come.
Closed Type Cooling Towers Shipment: Discover the convenience and reliability of our closed type cooling towers shipment process. At Newin (Guangdong) Machinery Co., Ltd., we go above and beyond to ensure that every unit is expertly packaged to prevent any damage during transit. With our thorough and efficient shipment practices, you can remain confident that your high-performance cooling solution will reach you safely and on time, ready to exceed your expectations.
Technical Strength& Standards
Certifications