Robust Cooling Tower System for Enhanced HVAC Performance

Product Details
Customization: Available
Cooling Method: Cross Flow
Ventilation Mode: Mechanical Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Robust Cooling Tower System for Enhanced HVAC Performance
  • Robust Cooling Tower System for Enhanced HVAC Performance
  • Robust Cooling Tower System for Enhanced HVAC Performance
  • Robust Cooling Tower System for Enhanced HVAC Performance
  • Robust Cooling Tower System for Enhanced HVAC Performance
  • Robust Cooling Tower System for Enhanced HVAC Performance
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NST series
Material
FRP
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO, CTI
Condition
New
Nominal Flow
800 M3/H
Motor Power
7.5*4 Kw
Fan Diameter
2400 mm
Net Weight
6080 Kg
Running Weight
18200 Kg
Water Pressure
42 Kpa
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
841950
Production Capacity
15000 Sets / Year

Product Description

NEWIN NST Series Robust Cooling Tower System for Enhanced HVAC Performance
Robust Cooling Tower System for Enhanced HVAC Performance
Product Description

NST series is a cross-flow design, induced draft open-loop cooling tower that excels in small to medium industrial, air-conditioning, and mechanical ventilation systems. Perfect for projects with lower water quality requirements.

Robust Cooling Tower System for Enhanced HVAC Performance

FEATURES
CTI Certified, Performance Ensurance

> High Efficiency Cooling
- Features dual-sided, fully open air intakes ensuring maximum air contact for optimal cooling.
- Equipped with an expansive area of infills, drastically enhancing heat exchange efficiency.
- Utilizes high-frequency transverse water flow for robust turbulent mixing, delivering remarkable cooling efficiency.

> Maximise Resource Utilization
- Designed to minimize water wastage and maximize ventilation, significantly cutting down on energy consumption.
- Constructed with largely recyclable materials, championing environmental protection.

> High Impact Resistant
- Rigid and stable infill layers and internal structure offer exceptional impact resistance, greatly reducing the risk of damage and blockage.

> Ease to Operate & Maintain
- Main structure boasts corrosion-resistant properties, ensuring ease of operation, low maintenance, and reduced operating costs.



MAIN PARTS
 
Robust Cooling Tower System for Enhanced HVAC Performance


1. High Efficiency Axial Fan
> Utilizes a renowned brand aluminum alloy axial fan known for high performance, reduced power consumption, and low noise levels.
> Employs superior quality V-belt and pulley, providing stable operation and effortless maintenance.
> Features a TEFC cooling tower duty motor with optional gear reducer. Available options include two-speed, variable speed, or explosion-proof motors.
> Offers an upgrade to a Permanent magnetic direct drive system, optimizing power consumption with energy efficiency rating up to IE5.


2. Uniform Water Distribution System
> Distributes water uniformly by gravity for consistent performance.
> Equipped with large diameter, non-clogging PP nozzles for wide spraying coverage.
> Features a removable steel cover for easy inspection and maintenance.
> Offers optional high-low flowrate nozzles, ensuring uniform water distribution even at varying flowrates.

3. Integrated Baffle Type Infill
> Constructed with high-quality self-extinguishing PVC infill for enhanced safety.
> Integrates formation infill and drift eliminator, providing a higher heat exchange area with superior performance drift eliminator to minimize drift loss below 0.005%.
> Optional infill for high or low temperature resistance, catering to special operating conditions.

4. Cold Water Basin
> Features an automatic water makeup system utilizing a stainless-steel mechanical float valve, renowned for its corrosion resistance and flexibility.
> Provides installation option for a water basin heater to meet frost protection needs during colder seasons.
 
5. Heavy Duty & High Stability Structure
> Constructed with Z700 HDGS corrosion-resistant material, secured with 304 Stainless Steel bolts and nuts for unmatched robustness and stability.
> Optional materials include 304/316 Stainless Steel or NWN-Armour for added versatility.

6. SMC Compressed Moulded
> Utilizes fiberglass fan stack material, offering resistance to corrosion and UV exposure.
> Enhances uniformity of airflow within the tower, reducing airflow resistance and ensuring efficient fan operation.

7. High Quality Fiberglass Panel
> Manufactured from fiberglass, providing resilience against corrosion and UV damage.
> Experience unparalleled durability with our innovative corrugated design, meticulously crafted to significantly enhance the robustness and extend the longevity of your cooling tower system.
> Customizable material options include top-of-the-line 304 / 316 Stainless Steel or the advanced NWN-Armour material, offering you the flexibility to meet specific requirements and enhance system resilience.

8. Access Door
> Designed to facilitate seamless access, our access door ensures hassle-free inspection and maintenance of the tower, thus optimizing operational efficiency.

9. Maintenance Platform
> Our state-of-the-art double layer maintenance platform is engineered for effortless internal cooling tower upkeep, providing a safer and more convenient solution, particularly during fan maintenance.

10. Cage Ladder & Handrail
Robust Cooling Tower System for Enhanced HVAC Performance
 
Product Parameters

Robust Cooling Tower System for Enhanced HVAC Performance

Tower Model Outline dimensions (mm) Weight (Kg)
NST W L H Dry Wet
NST-18-A15-2A11-C1 3310 1800 3500 1030  2480 
NST-20-B15-2A12-C1 3310 2000 3700 1110  2730 
NST-26-D18-3A14-C1 4080 2600 4110 1660  4130 
NST-30-D21-3A16-C1 4220 3000 4540 1890  4860 
NST-33-E24-3A17-C1 4540 3300 4790 2080  5520 
NST-35-F26-4A17-C1 5350 3500 4890 2960  8290 
NST-40-F30-4B17-C1 5750 4000 4940 3310  9690 
NST-43-G32-4B18-C1 5950 4300 5140 3550  10620 
NST-46-H34-4B20-C1 6150 4600 5560 3900  11740 
NST-48-H40-5B18-C1 7420 4800 5390 4560  13970 
NST-50-I42-5B20-C1 7560 5000 5610 5190  15280 
NST-54-J42-5B22-C1 7560 5400 6010 5650  16690 
NST-60-J47-5B22-C1 8040 6000 6210 6330  19120 


Explore the Upgraded NST Series - Our FRP Cooling Tower Solutions Tailored for Versatile Working Conditions
 
Robust Cooling Tower System for Enhanced HVAC Performance
Robust Cooling Tower System for Enhanced HVAC Performance
Robust Cooling Tower System for Enhanced HVAC Performance



OPTIONS
 
Introducing the Permanent Magnetic Direct-Driven Fan System
Ingenious Energy Saving Design

> Experience optimal efficiency with variable frequency control, facilitating low-speed operation and a superior power factor.
> Enjoy seamless performance with our direct-driven fan, eliminating transmission losses and requiring no maintenance.
> Achieve exceptional energy savings with an energy efficiency rating reaching up to IE5, significantly reducing power consumption.
Robust Cooling Tower System for Enhanced HVAC Performance

Robust Cooling Tower System for Enhanced HVAC Performance
NWN-Armour Corrosion Resistant Technology
Revolutionary Corrosion Resistant Design

Boasting a galvanized steel panel adorned with the advanced NWN-Armour anti-corrosion coating, this design rivals Stainless Steel in durability, offering a cost-effective substitute.

Additional Accessories
Enhance your system with options like the PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction tools.
NEWIN Manufacturing Base

Robust Cooling Tower System for Enhanced HVAC Performance
Explore the NEWIN FACTORY
Our Manufacturing base, strategically located in Huizhou, Guangdong, spans an impressive 10,000 square meters.

Prestigious ISO CERTIFICATION
Proudly certified with ISO9001:2015 Quality Management System and ISO14001:2015 Environmental Management System, showcasing our commitment to excellence.

State-of-the-Art WORKSHOPS
Precision-focused Welding Workshop
Innovative Filler Thermoforming Workshop
Advanced Sheet Metal Processing Workshop
Efficient Cooling Tower Assembly Workshop

Rigorous TESTING Protocols
Featuring an Independent Testing LAB for unmatched quality assurance.

Robust Cooling Tower System for Enhanced HVAC Performance
NEWIN COOLING TOWERS: Engineered for Excellence

· NWN/ NWF/ NCFN Our Closed Type Cooling Tower Series sets the industry standard.
· NSH/ NST Designed for efficiency, our Open Type Cooling Tower Series is unparalleled.
· NTG Industrial Type Cooling Tower Series: Built for robust industrial use.
· NECN/NECH Innovative Evaporative Condenser for superior performance.
· NWFL Eco-friendly Dry Air Cooler for sustainable cooling solutions.

Robust Cooling Tower System for Enhanced HVAC Performance
NEWIN offers a comprehensive range of cooling tower accessories to fulfill maintenance and replacement requirements, catering to almost any size and type of cooling tower. Reach out to us for customized accessory solutions.

INCLUDES:
· Fan drive system (incorporating fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (featuring nozzles/ drift eliminator etc.)
· Heat exchange components (such as PVC infills/ cooling coil etc.)
· Additional accessories (air inlet louver/ valve etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience a hassle-free shipping process for our open type cooling towers, designed for optimal performance and efficiency. Our logistics team ensures timely delivery and handles every detail with care, ensuring that your cooling towers arrive promptly, ready to integrate seamlessly into your HVAC system.

Robust Cooling Tower System for Enhanced HVAC Performance
Closed Type Cooling Towers Shipment: Our closed type cooling towers are shipped with the utmost precision and attention to detail. Each unit is carefully packaged to preserve its integrity during transit, guaranteeing that it reaches your location intact and fully operational, prepared to deliver exceptional cooling performance for your HVAC needs.
Robust Cooling Tower System for Enhanced HVAC Performance
Robust Cooling Tower System for Enhanced HVAC Performance
Technical Strength& Standards

Robust Cooling Tower System for Enhanced HVAC Performance
Robust Cooling Tower System for Enhanced HVAC Performance

Certifications

Robust Cooling Tower System for Enhanced HVAC PerformanceRobust Cooling Tower System for Enhanced HVAC PerformanceRobust Cooling Tower System for Enhanced HVAC PerformanceRobust Cooling Tower System for Enhanced HVAC Performance

Robust Cooling Tower System for Enhanced HVAC Performance


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier