Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
  • Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
  • Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
  • Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
  • Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
  • Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
SHH
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC or PP or UPVC
Sheet Space
20mm
Sheet Thickness
Erature 50ºC ~ -35ºC
Trade Terms
Fob, CIF, CFR, DDU.
Minimum Order Quantity
1000PCS
Width
950 mm
Transport Package
20/40/40hq Container with Loose Packing
Specification
950 x 950 mm, 950 x 1270 mm
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
1000000mt Per Year

Product Description

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

SHH Cross Flow Film Fill:


Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

Product Description

SHH Newin SHH series cross flow film fill is used for square cooling tower, with the advanced technical, long lifetime, low resistance, light weight. The surface is smooth and bright, pressure strength is strong, it will not break when touched, non-toxic and non-irritating, more safer.High quality new PVC raw material, guaranteed quality, durability, through the test and production operation show that the cooling effect is good.


 

Features

- Using modified PVC sheet, unique modified formula makes the infill strong resistance and high durability.
- Vac form special processing, the inner side (fan side) edge with integrated liquid baffle plate, and controls the drift loss of water in minimum value, and maximize the heat exchange performance of the water and air.
- Standard heat temperature of 50 ° C, heatproof specification (optional) can use up to 80 ° C.

 
Parameter

PROPERTIES

With different request in SHH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Width  mm 950/1270
Module Height  mm 950
Module Depth   mm -
Flute Height  mm 20
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 147
Sheet Thickness - Before Forming  mm 0.32
Sheet Thickness - After  Forming  mm 0.28
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.
 


Structure & Installation Drawing

Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

 

Application

APPLICATION & USAGE

Newin SHH Film Fill is applicable for other brands crossflow cooling tower, with SGS test in ASTM Standards to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower



Applicable Commercial Standards

Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.
 


Filed Data for Cross Flow Film Fill Replacement

Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components. 
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Options

You may also find these offerings intriguing:

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
NEWIN Manufacturing Base

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
NEWIN FACTORY
Embark on an inspiring journey through our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Spanning an impressive 10,000 square meters, this facility is a beacon of innovation, excellence, and technological advancement.

ISO CERTIFICATION
Proudly underscoring our unwavering dedication to superior quality and environmental stewardship, we hold prestigious ISO certifications. Our ISO9001:2015 Quality Management System and ISO14001:2015 Environmental Management System Certifications set benchmarks for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series. These towers are meticulously designed to deliver superior performance and unmatched reliability, embodying the forefront of cooling tower technology.
· NSH/ NST Discover steadfast reliability with our Open Type Cooling Tower Series, expertly crafted for optimal operation and robust performance. Setting industry standards, these towers exceed expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, designed to conquer heavy-duty and demanding applications. These towers ensure resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These models set new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, designed for superior airflow and maximum efficiency. This cooler optimizes every facet of cooling for unmatched results.

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
NEWIN is your trusted partner for premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories for optimal performance.

CONTAIN:
· A robust Fan drive system, featuring a fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, equipped with precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, including top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system. These enhance overall functionality and efficiency, elevating performance.
 
Packaging & Shipping

Open type cooling towers shipment: Our expertly crafted open-type cooling towers are thoughtfully packaged to maintain their impeccable condition upon arrival. We employ top-tier materials and advanced packing strategies to effectively guard against transit-related damages. Revel in our seamless logistics and timely delivery, guaranteeing that your cooling solutions are poised for action without delay.

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Closed type cooling towers shipment: Enjoy unparalleled assurance with our resilient packaging solutions for closed-type cooling towers. Each tower is meticulously encased to endure the demands of transportation, ensuring they arrive at your location in perfect condition and performance-ready. Our steadfast commitment to quality control and punctual shipping allows you to concentrate on the essence of your operations-harnessing our cutting-edge cooling technology for your specific applications.
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Technical Strength& Standards

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower
Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

Certifications

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling TowerShinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling TowerShinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling TowerShinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower

Shinwa Cross Flow Cooling Tower Infill /Fills/Filling/Filter/for Replacing Shinwa Cooling Tower


 

 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More