• Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
  • Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
  • Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
  • Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
  • Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
  • Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming

Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Material: FRP
Air Contact Form: Wet
Air Contact Way: Open
Tower Shape: Square
Customization:

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
NTG series
Noise Level
Ordinary
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Cooling Capacity
2000rt
Cooling Media
PVC/PP Film Fill
Application
Water Treatment
Motor Brand
Siemens/ABB
Tower Frame Material
Hot DIP Galvanized Steel(Hdgs)
Casing and Water Basin
FRP/Concrete/SUS304
Foundation
Concrete #C20
Service Life
25years
Guarantee
2 Years After Start up
Brand
Newin
Transport Package
40 Container Loading Loose Packing
Specification
CTI
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
15000 Sets/Year

Product Description

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
NTG series Industrial Cooling Tower is widely used in industries of Electric Power, Petroleum, Chemical Engineering, Chemical Fertilizer, Smelt, etc. Cooling water capacity ranges from 800 m3/h - 4000 m3/h. According to Customers' request, we also supply high temperature type, sewage type, and also designed to different shape to match with the customer's site location.

NTG Cooling Tower Structure

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
Tower framework
Made of steel or concrete or FRP to composed of a space frame, taken effective anti-corrosion measures for components, overall stability, good rigidity.

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
Fan Stack
F.R.P material, with steel tension bar and protector, and includes reasonable aerodynamic performance design, to make the Fan stank great strength and high efficiency. 

Water distribution system
Used pipe distribution, distribution nozzle is imported USA DESP's technology, its salient features is gravity without pressure, spraying water as   uniform square, adjustable spraying area, which made the cooling tower water distribution more reasonable, but also greatly reduce the energy consumption of cooling tower. 

Infill
NTF series infill Made of  PP material, high temperature and corrosion resistant; combined the features of trickle fill and film fill, improving water distribution to achieve higher heat tranfer by further scatter the spray water.

Fan Assembly
The efficient FRP cooling fan which combines the highest aerodynamic performance with very low power consumption. Large air volume, high efficiency, low noise, corrosion resistant.  


Sumitiomo Brand Gear Reducer
Sumitomo reducer, horizontal, low noise, high efficiency and reliable lubrication, maintenance is convenient, equipped with oil moderate vibration alarm device. The service factor: 2.0


Murphy Brand Vibration Switch
Original imported Murphy brand vibration switch ensure the stable and long term reliable service life.


NTG-1000 series cooling tower series drawing

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming

NTG Series Cooling Tower Technical Data
Item  Water Flow
(m3/h)
Cooling  
Capacity
Kcal/h
Dimention
(mm)
Fan Water
Pressure
(x104Kpa)
Weight (kg)
  Model Length Width Height Diameter
(mm)
Power
(Kw)
Dry Wet
NTG-800 800 8.0x106 7400 7400 7800 4700 30 8.0  11.63  18.45 
NTG-1000 1000 1.0x106 9000 9000 8700 5460 45 8.8  19.68  31.23 
NTG-1500 1500 1.5x107 10500 10500 9500 6000 55 10.0  29.34  46.75 
NTG-2000 2000 2.0x107 12000 12000 10200 7700 90 11.0  45.03  68.69 
NTG-2500 2500 2.5x107 13500 13500 10700 8000 132 11.5  46.20  75.30 
NTG-3000 3000 3.0x107 15000 15000 11400 8530 160 12.0  65.00  99.20 
NTG-3500 3500 3.5x107 16000 16000 12100 9140 160 13.3  76.05  104.80 
NTG-4000 4000 4.0x107 17400 17400 12400 9140 200 13.5  78.50  132.00 

Factory 

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
NEWIN NTG cooling tower project cases
Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
Cooling Tower Shipment

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming

NEWIN COOLING TOWER

Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming
Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming


Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming Industrial Cooling Tower for Steel Mill Steel Structure FRP Coaming

Send your message to this supplier

*From:
*To:
avatar Mr. Kelvin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now