FRP Big Industry Water Cooling Tower for Power Station

Product Details
Customization: Available
Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • FRP Big Industry Water Cooling Tower for Power Station
  • FRP Big Industry Water Cooling Tower for Power Station
  • FRP Big Industry Water Cooling Tower for Power Station
  • FRP Big Industry Water Cooling Tower for Power Station
  • FRP Big Industry Water Cooling Tower for Power Station
  • FRP Big Industry Water Cooling Tower for Power Station
Find Similar Products

Basic Info.

Model NO.
NTG series
Material
FRP
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Cooling Capacity
1000rt
Cooling Media
PVC/PP Film Fill
Application
Water Treatment
Motor Brand
Siemens/ABB
Tower Frame Material
Hot DIP Galvanized Steel(Hdgs)
Casing and Water Basin
FRP/Concrete/SUS304
Foundation
Concrete #C20
Service Life
25years
Guarantee
2 Years After Start up
Brand
Newin
Transport Package
40 Container Loading Loose Packing
Specification
CTI
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
15000 Sets/Year

Product Description

FRP Big Industry Water Cooling Tower for Power Station

FRP Big Industry Water Cooling Tower for Power Station
NTG- F series F.R.P Framework Industrial Cooling Tower is type of open circuit cooling tower designed to special applicant in corrosive liquid cooling process due to its higher corrosion resistance, design life is up to 30 years, highly used in Pharmaceutical industry, Metail casting, Paper industry, Steel plant, Cement factory, Power plant, Petrochemical industry, Sugar factory, ect. Cooling capacity from 800 to 4000 m³/ hr.

NTG Cooling Tower Structure

FRP Big Industry Water Cooling Tower for Power StationFRP Big Industry Water Cooling Tower for Power Station
Tower framework
Made of steel or concrete or FRP to composed of a space frame, taken effective anti-corrosion measures for components, overall stability, good rigidity.

FRP Big Industry Water Cooling Tower for Power Station


Fan Stack
F.R.P material, with steel tension bar and protector, and includes reasonable aerodynamic performance design, to make the Fan stank great strength and high efficiency. 

Water distribution system
Used pipe distribution, distribution nozzle is imported USA DESP's technology, its salient features is gravity without pressure, spraying water as   uniform square, adjustable spraying area, which made the cooling tower water distribution more reasonable, but also greatly reduce the energy consumption of cooling tower. 

Infill
NTF series infill Made of  PP material, high temperature and corrosion resistant; combined the features of trickle fill and film fill, improving water distribution to achieve higher heat tranfer by further scatter the spray water.

Fan Assembly
The efficient FRP cooling fan which combines the highest aerodynamic performance with very low power consumption. Large air volume, high efficiency, low noise, corrosion resistant.  


Sumitiomo Brand Gear Reducer
Sumitomo reducer, horizontal, low noise, high efficiency and reliable lubrication, maintenance is convenient, equipped with oil moderate vibration alarm device. The service factor: 2.0


Murphy Brand Vibration Switch
Original imported Murphy brand vibration switch ensure the stable and long term reliable service life.


NTG-1000 series cooling tower series drawing

FRP Big Industry Water Cooling Tower for Power Station

NTG Series Cooling Tower Technical Data
Item  Water Flow
(m3/h)
Cooling  
Capacity
Kcal/h
Dimention
(mm)
Fan Water
Pressure
(x104Kpa)
Weight (kg)
  Model Length Width Height Diameter
(mm)
Power
(Kw)
Dry Wet
NTG-800 800 8.0x106 7400 7400 7800 4700 30 8.0  11.63  18.45 
NTG-1000 1000 1.0x106 9000 9000 8700 5460 45 8.8  19.68  31.23 
NTG-1500 1500 1.5x107 10500 10500 9500 6000 55 10.0  29.34  46.75 
NTG-2000 2000 2.0x107 12000 12000 10200 7700 90 11.0  45.03  68.69 
NTG-2500 2500 2.5x107 13500 13500 10700 8000 132 11.5  46.20  75.30 
NTG-3000 3000 3.0x107 15000 15000 11400 8530 160 12.0  65.00  99.20 
NTG-3500 3500 3.5x107 16000 16000 12100 9140 160 13.3  76.05  104.80 
NTG-4000 4000 4.0x107 17400 17400 12400 9140 200 13.5  78.50  132.00 

Factory 

FRP Big Industry Water Cooling Tower for Power Station
NEWIN NTG cooling tower project cases
FRP Big Industry Water Cooling Tower for Power Station
Cooling Tower Shipment

FRP Big Industry Water Cooling Tower for Power Station

NEWIN COOLING TOWER

FRP Big Industry Water Cooling Tower for Power Station
FRP Big Industry Water Cooling Tower for Power Station
FRP Big Industry Water Cooling Tower for Power Station


FRP Big Industry Water Cooling Tower for Power StationFRP Big Industry Water Cooling Tower for Power StationFRP Big Industry Water Cooling Tower for Power Station

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier