Drift Eliminator Internal for High Performance Cooling Towers

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Drift Eliminator Internal for High Performance Cooling Towers
  • Drift Eliminator Internal for High Performance Cooling Towers
  • Drift Eliminator Internal for High Performance Cooling Towers
  • Drift Eliminator Internal for High Performance Cooling Towers
  • Drift Eliminator Internal for High Performance Cooling Towers
  • Drift Eliminator Internal for High Performance Cooling Towers
Find Similar Products
  • Overview
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MBD
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC
Transport Package
Wooden Case or 20gp/40gp Container
Specification
Height: 146 mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

Introducing the Drift Eliminator, a cutting-edge solution meticulously engineered for optimizing performance in cooling towers.

Drift Eliminator Internal for High Performance Cooling Towers

MBD Newin MBD series cellular drift eliminator is a precision device crafted to efficiently capture and remove minuscule water droplets that become entrained within the exhaust air stream. This innovative solution significantly curtails the potential nuisances and health concerns these droplets might pose if they were permitted to escape through the tower's apex alongside the heated air. The MBD series employs a sophisticated tortuous path design for the airflow, compelling water droplets to alter their trajectory. This results in them impacting the side walls of the drift eliminator, where they then coalesce and seamlessly drain back into the wet section of the cooling tower, ensuring optimal operational efficiency.
 


FEATURES

- Exceptional anti-aging properties combined with superior water absorption capabilities.
- Minimal airflow resistance paired with robust structural integrity.
- Effortless installation and an impressively extended service life.
- Versatile enough to serve as an efficient replacement for air inlet louvers.
Parameter

PROPERTIES

For those seeking the perfect solution in MBD drift eliminators, Newin (Guangdong) Machinery Co., Ltd. is at your service. Whether you have specific needs regarding length, width, materials, or thickness, simply inform us of your detailed requirements. We ensure a tailored and precise solution to meet your unique specifications. Our drift eliminators can also be crafted with flame retardant or anti-bacterial properties upon request, ensuring that every customer need is impeccably met.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Height  mm 146
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.38
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.



STRUCTURE & INSTALLATION DRAWING

At Newin (Guangdong) Machinery Co., Ltd., we provide detailed structure and installation drawings, making the setup process as seamless as possible. Accompanied by jobsite storage advice and a comprehensive quality control report, we ensure that our customers are well-informed upon receiving their materials. Additionally, we offer the flexibility of OEM services and special mold designs to cater to individual preferences, available upon request.

Drift Eliminator Internal for High Performance Cooling Towers
Application

APPLICATION & USAGE

The remarkable Newin MBD cellular drift eliminator is expertly crafted for replacing the components of cooling towers. Adhering to SGS testing within ASTM Standards, it ensures the ultimate in high-quality infill, maximizing the efficiency of your cooling tower like never before. Simply inform us of your tower model or dimensions, and we'll adeptly estimate the necessary number of sheets for your replacement project.Drift Eliminator Internal for High Performance Cooling Towers


Applicable Commercial Standards

The materials for these sheets are meticulously tested under SGS guidelines, fully compliant with ASTM standards. Each property, or a comprehensive suite of properties, can be tested as per your request, ensuring unwavering quality and performance.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Cellular Drift Eliminator Replacement

For those seeking excellence in maintenance or repair projects, rely on Newin for unparalleled quality and reliability. Fill in the measurement data below, and let us provide site visits or maintenance service engineered to seamlessly fit your cooling tower fills or components. Trust in Newin-where precision meets dependability.
Drift Eliminator Internal for High Performance Cooling Towers
NEWIN Manufacturing Base

Drift Eliminator Internal for High Performance Cooling Towers
NEWIN FACTORY
Embark on an inspiring journey through our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Spanning an expansive 10,000 square meters, this facility is a beacon of innovation and technological advancement. Immerse yourself in an environment where pioneering breakthroughs and excellence converge, setting new standards in manufacturing.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: ISO9001:2015 Quality Management and ISO14001:2015 Environmental Management. These certifications exemplify our dedication to setting industry benchmarks for excellence and responsible practices.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Drift Eliminator Internal for High Performance Cooling Towers
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Immerse yourself in unrivaled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series. Each model is meticulously designed to deliver superior performance and unmatched reliability, embodying the pinnacle of cooling tower technology.
· NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance. These towers set industry standards and consistently exceed expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty applications. These towers ensure resilience and power at every turn, meeting the demands of the most challenging environments.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These models set new standards in performance and operational excellence, revolutionizing the cooling industry with unparalleled innovation.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler. Expertly designed for superior airflow and maximum efficiency, this cooler optimizes every facet of cooling, delivering unmatched results.

Drift Eliminator Internal for High Performance Cooling Towers
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories for optimal cooling tower performance.

CONTAIN:
· A robust Fan drive system, featuring a fan, fan stack, reducer, motor, and shaft. Engineered for durability and precision, this system ensures seamless operation.
· Highly efficient Water distribution components, with precision-engineered nozzles and advanced drift eliminators. These components optimize water management for superior performance.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils. Crafted for optimal performance and energy efficiency, these options enhance thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system. These accessories enhance overall functionality and efficiency, elevating performance.
 
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, ensuring they reach you in immaculate condition. We prioritize the utmost safety and security, deploying premium materials and strategic packing techniques to offer an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, so your cooling solutions become operational without delay, ensuring maximum efficiency and top-tier performance.

Drift Eliminator Internal for High Performance Cooling Towers
Closed type cooling towers shipment: Experience peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to withstand the rigors of transport, ensuring arrival at your site in pristine condition, ready to deliver exceptional performance. Our steadfast dedication to quality control and punctual shipping empowers you to focus on what truly matters - harnessing our advanced cooling technology to elevate your applications and achieve unparalleled success.
Drift Eliminator Internal for High Performance Cooling Towers
Drift Eliminator Internal for High Performance Cooling Towers
Technical Strength& Standards

Drift Eliminator Internal for High Performance Cooling Towers
Drift Eliminator Internal for High Performance Cooling Towers

Certifications

Drift Eliminator Internal for High Performance Cooling TowersDrift Eliminator Internal for High Performance Cooling TowersDrift Eliminator Internal for High Performance Cooling TowersDrift Eliminator Internal for High Performance Cooling Towers

Drift Eliminator Internal for High Performance Cooling Towers



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More