Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation

Product Details
Customization: Available
Cooling Method: Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, CE, SGS
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
  • Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
  • Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
  • Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
  • Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
  • Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NAL Series
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ordinary
Material
PVC
Application Fields
Cross Flow Cooling Tower
Model--Lah
PVC
Size
65/70thicknessx Any Length X Any Width
Continuous Operation Tempperature
50 Degree Centigrade
Max.Applicationtemp. (Short Term)
60 Degree Centigrade
Color
Black
Corrugation Height
18 mm
Thickness
65/70mm
Application
Cross Flow Square Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Specification
65/70mm thickness
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

Experience superior air inflow capabilities with our PVC Material Cooling Tower Fill Nal Air Inlet Louver, engineered to perfection.

Introducing the NAL series, your ultimate choice for advanced airflow management. The Newin NAL series air inlet louver is crafted to elevate your cooling efficiency with precision engineering. Expertly designed, itis constructed from high-strength PVC sheets that are securely bonded to ensure durability. The outer frame is available in galvanized steel or stainless steel, catering to diverse needs. The state-of-the-art honeycomb inlet grille enhances the cooling tower's performance by optimizing airflow, efficiently filtering impurities, and preventing water splash. This innovation reduces the risk of icing, minimizes water damage, and curtails unnecessary water loss, ensuring optimal functionality.

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation

 
 
Features

Features that Elevate Efficiency

· Ingeniously designed to prevent debris from making its way into your system.
· Effectively stops the splash of water droplets, ensuring a cleaner operation.
· Restricts sunlight penetration into the cooling tower, effectively impeding algae growth.
· Significantly reduces noise emissions from the tower, creating a more serene environment.
· Engineered to achieve an impressively low pressure drop, enhancing performance.
· Boasts effortless installation with easy access for regular cleaning and maintenance.
· Adaptable for a multitude of new and retrofit applications, including air inlets for both package.
and field-erected counter flow and straight-sided cross flow towers, as well as fresh air make-up systems, and air pollution control scrubbers.

 
Parameter

Properties
With the NAL air inlet louver, Newin caters to various specifications including length, width, material, and thickness. Communicate your precise requirements for a tailored solution and competitive offer. Newin proudly fulfills all customer demands, offering optional fill media in flame-retardant or anti-bacterial variants upon request.

Module Length (Max)  mm 2440
Module Width (Max)  mm 600
Module Thickness  mm 65
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing
Newin provides a comprehensive structure and installation drawing, along with jobsite storage guidance and a meticulous quality control report. These accompany every shipment to ensure customers receive materials in prime condition. OEM or custom mold design is available for those seeking specialized solutions.Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation

Application

Application & Usage

The Newin EVL air inlet louver is expertly crafted for integration into counter flow cooling towers. It boasts SGS-certified testing under stringent ASTM Standards, ensuring the highest quality infill for optimal cooling tower performance. Share your tower model or dimensions with us, and we'll accurately assess and provide the perfectly sized air inlet louver for seamless replacement.
Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation


Applicable Commercial Standards
The sheet material for our products rigorously adheres to SGS testing under ASTM standards. Each property, as outlined below, has been evaluated and can be verified upon request to ensure compliance with your exacting requirements.

Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Air Inlet Louver Replacement
To ensure top-tier performance and dependability for your maintenance or repair cooling tower projects, fill in the measurement data below. Trust Newin for quality you can count on, whether it's a site visit or maintenance service, engineered to perfectly align with your cooling tower fills or components. Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation

NEWIN Manufacturing Base

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
 
Packaging & Shipping

Open type cooling towers shipment: Experience unmatched security and precision with our meticulously orchestrated transportation service tailored specifically for open-type cooling towers. Each tower is encased in top-tier materials and employs advanced packing techniques to ensure they arrive at your location in impeccable condition. Our steadfast commitment to protecting your valuable investment ensures comprehensive security against potential transit challenges. Delight in the ease of our efficient logistics and prompt delivery, perfectly crafted to initiate your cooling solutions promptly and seamlessly.

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
Closed type cooling towers shipment: Bask in the confidence provided by our premier packaging solutions, custom-designed for closed-type cooling towers. Each unit is enveloped with exceptional care, ensuring resilience against the trials of rigorous transportation, and guaranteeing their flawless arrival and immediate operational readiness. Our relentless pursuit of excellence and rapid delivery empowers you to seamlessly integrate our cutting-edge cooling technologies into your infrastructure, liberating you from any logistical concerns.
Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
Technical Strength& Standards

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation
Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation

Certifications

Versatile Air Inlet Louver for Open Air Contact and Mixing VentilationVersatile Air Inlet Louver for Open Air Contact and Mixing VentilationVersatile Air Inlet Louver for Open Air Contact and Mixing VentilationVersatile Air Inlet Louver for Open Air Contact and Mixing Ventilation

Versatile Air Inlet Louver for Open Air Contact and Mixing Ventilation








 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More