Introducing our Premium Cooling Tower Cross Flow Fill, meticulously crafted from high-quality PVC material. Available in versatile widths of 950mm and 1270mm, this innovative solution is designed to optimize performance and ensure superior airflow efficiency in your cooling tower applications. Experience unparalleled durability and functionality with our expertly engineered fill systems, tailored to meet the rigorous demands of modern cooling infrastructures.
Product Description
SHH Introducing the Newin SHH Series Cross Flow Film Fill—a revolutionary component crafted for square cooling towers with unmatched technological advancements. Experience unparalleled longevity and minimal resistance packaged in a featherlight design. Revel in its flawlessly smooth and lustrous surface, reinforced to withstand pressure without fracturing. Its non-toxic and non-irritating nature ensures enhanced safety. Constructed from premium-grade, newly-sourced PVC raw material, the SHH series promises assured quality and remarkable durability. Rigorous testing and operational assessments testify to its superior cooling efficacy.
FEATURES
- Crafted from modified PVC sheets, its exclusive formula endows the infill with extraordinary resistance and exceptional durability.
- Precise vacuum form processing with an integrated liquid baffle plate on the fan side edge significantly curtails drift loss, optimizing heat exchange efficiency between water and air.
- Standard heat temperature endurance is set at 50 °C, with optional heatproof specifications that endure temperatures up to an impressive 80 °C.
PICTURE IN DETAIL

Parameter
PROPERTIES
Do you have specific requirements for SHH film fill, such as unique dimensions, materials, or thickness? Share your detailed needs, and we'll tailor a precise solution and offer for you. Newin is committed to accommodating every customer specification. Additionally, we offer fill media in both flame retardant and anti-bacterial versions, available upon request.
Module Length (Max) |
mm |
950 |
Module Width |
mm |
950/1270 |
Module Depth |
mm |
- |
Flute Height |
mm |
20 |
Flute Corrugation Angle |
degrees |
- |
Surface Area |
m2/m3 |
147 |
Sheet Thickness - Before Forming |
mm |
0.32 |
Sheet Thickness - After Forming |
mm |
0.28 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - High temp. |
°C |
80 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
To enhance your experience, Newin provides comprehensive structure and installation drawing guidance, along with on-site storage advice and a quality control report, all included with your shipment. This ensures that our customers receive their materials with utmost care and attention. Furthermore, we offer OEM services and are capable of designing special molds to cater to your unique requirements upon request.
Application
APPLICATION & USAGE
The Newin SHH Film Fill is designed exclusively for Shinwa cooling tower series, offering unparalleled compatibility and performance.
Specifically compatible models include SNC-U, and SDC-U Field Erected.Our fill undergoes rigorous SGS testing according to ASTM Standards, ensuring premium quality infill that maximizes the efficiency of your cooling tower. Simply inform us of your tower model or size, and we will precisely estimate the number of sheets needed to replace your cooling tower fill.
FILED DATA FOR CROSS FLOW FILM FILL REPLACEMENT
Please provide the measurements data below for your maintenance cooling tower or repair projects. When quality and reliability are paramount, rely on Newin for expert site visits or maintenance services. Our engineering precision ensures a perfect fit for all cooling tower fills or components.
Options
Explore Additional Captivating Possibilities:

NEWIN Manufacturing Base

NEWIN FACTORY
Embark on an awe-inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the dynamic industrial hub of Huizhou, Guangdong. Stretching over an expansive 10,000 square meters, this facility stands tall as a beacon of innovation, excellence, and cutting-edge technological advancements.
ISO CERTIFICATION
We proudly emphasize our unwavering commitment to unrivaled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for unmatched excellence.
WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Experience unparalleled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model showcases the pinnacle of cooling tower technology.
·
NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry benchmarks and consistently exceeding expectations for enduring excellence.
·
NTG Explore the extraordinary capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
·
NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
·
NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unparalleled results.
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a wide variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories designed for your cooling tower to achieve optimal performance.
CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping
Open type cooling towers shipment: Experience unmatched security and precision with our expertly coordinated transportation services for open-type cooling towers. Each tower is enveloped in premium-grade materials and cutting-edge packing techniques, ensuring they arrive at your location in perfect condition. Our unwavering dedication to protecting your investment results in comprehensive coverage against potential transit risks. Relish the convenience of our seamless logistics and prompt delivery, meticulously planned to activate your cooling solutions without delay.
Closed type cooling towers shipment: Enjoy the assurance of our superior packaging solutions specifically designed for closed-type cooling towers. Each unit is encased with exceptional care and durability to endure the most challenging transit conditions, ensuring they arrive in pristine condition and are ready for immediate deployment. Our steadfast commitment to excellence and rapid delivery enables you to seamlessly integrate our cutting-edge cooling innovations into your operations, without any logistical concerns.
Technical Strength& Standards