• Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
  • Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
  • Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
  • Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
  • Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
  • Supply Counter Flow Closed Circuit Cooling Tower with Water Tank

Supply Counter Flow Closed Circuit Cooling Tower with Water Tank

Cooling Method: Counter Flow
Ventilation Mode: Mixing Ventilation
Material: Metal
Air Contact Form: Wet and Dry
Air Contact Way: Closed
Tower Shape: Square
Customization:
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
NWN
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Water Capacity
25m&M3;/H
Inlet/Outlet Temperature
37/32c
Air Volume
36600m3/H
Fan Power
2.2kw
Inlet/Outlet Pipe Size
Dn40
Circulating Pump Power
1.5kw
Circulating Water Flow
45m3/H
Net/Operation Weight
750kg/1700kg
Case Material
Galvanized Steel Plate
Coil Material
Cooper/SUS304
Transport Package
Wood Packing, 20gp, 40gp Container Loading
Specification
CE, UL, CTI
Trademark
NEWIN
Origin
Shenzhen China
HS Code
84195000
Production Capacity
1000sets/Month

Product Description

Supply Counter Flow Closed Circuit Cooling Tower with water tank
Supply Counter Flow Closed Circuit Cooling Tower with Water Tank


NWN series counter flow closed type cooling tower, also called Induced Draft Evaporative Closed Circuit Coolers, Closed loop system design, Trouble-free process operation-closed loop protection of process fluids and equipment from external contamination, Widely used in data centres, battery plants, grow room facilities, high-efficiency chiller applications and multiply different types of industrial process. 

Feature
Large internal space & smaller occupied area.
Excellent heat exchange performance & smaller wind resistant.
Non-stop maintenance & simple maintenance work.
Closed circuit design ensures high water quality .
Supply Counter Flow Closed Circuit Cooling Tower with Water Tank


WATER TANK

Stainless Steel Water Tank, high stability, compression resistance and anti-corrosion.
Supply Counter Flow Closed Circuit Cooling Tower with Water TankThe necessity of providing closed circuit cooling tower with circulating water tank:

- Replenishing water into circulating system of closed circuit cooling tower ( specially add antifreeze appropriately from water tank in winter) .
- Has stead preesure funtion, properly pressurize and depressurize for closed circuit cooling tower during whole circulating process, preventing water - overflow.
- Excluding excess air of pipes and cooling coil in closed circuit cooling tower.Excluding the coil medium to the water tank when the closed circuit  cooling tower stopped in winter, so that to antifreeze.

Supply Counter Flow Closed Circuit Cooling Tower with Water Tank

Technical Specification of NWN Series Cooling Tower
Model Cooling Capacity (Kw) Fan Power     (Kw) Pump Power (Kw)  Dimension (mm) Weight (kg)
Length Width Height Dry Wet
NWN-230-Z7-S 230 1.5*2 0.75Kw 2500 1100 2750 2950 5000
NWN-290-Z7-S 290 1.5*2 0.75Kw 2500 1100 2750 3150 5500
NWN-350-Z7-S 350 2.2*2 1.1Kw 2500 1200 2750 3350 6000
NWN-450-Z7-S 450 2.2*3 1.5Kw 4250 1450 3100 4150 6800
NWN-600-Z7-S 600 2.2*3 1.5Kw 4250 1450 3100 5550 7800
NWN-750-Z7-S 750 5.5*2 2.2Kw 4250 1750 3520 6050 8500
NWN-850-Z7-S 850 5.5*2 2.2Kw 4250 2250 3620 7120 10500
NWN-1000-Z7-S 1000 5.5*2 3.0Kw 4250 2250 3620 7150 9500
NWN-1150-Z7-S 1150 7.5*2 4.0Kw 5750 2250 3860 7720 11500
NWN-1300-Z7-S 1300 7.5*2 5.5Kw 5750 2250 3860 8300 12700
NWN-1450-Z7-S 1450 11*2 5.5Kw 5750 2500 4240 10680 14600
NWN-1750-Z7-S 1750 11*2 7.5Kw 5750 3000 4340 12100 16200

Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
Factory 

Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
NEWIN NWN cooling tower project cases

Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
Cooling Tower Shipment

Supply Counter Flow Closed Circuit Cooling Tower with Water Tank

NEWIN COOLING TOWER


Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
Supply Counter Flow Closed Circuit Cooling Tower with Water Tank
Supply Counter Flow Closed Circuit Cooling Tower with Water Tank


Supply Counter Flow Closed Circuit Cooling Tower with Water TankSupply Counter Flow Closed Circuit Cooling Tower with Water TankSupply Counter Flow Closed Circuit Cooling Tower with Water Tank









 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
OEM/ODM Availability
Yes