Introducing the Low Noise High Efficiency Water Cooling Tower NST Series- Elevate your HVAC and air conditioning systems to new heights with this cutting-edge cooling technology from Newin (Guangdong) Machinery Co., Ltd. Our water cooling tower is meticulously engineered to deliver exceptional performance while maintaining whisper-quiet operation. Experience the pinnacle of efficiency and tranquility in cooling solutions, ensuring optimal functionality in any environment.
Product Description
NST series is a marvel of engineering, boasting a cross-flow design with an induced draft open-loop configuration. This cooling tower is a versatile choice, frequently employed in small to medium-sized industrial settings, air-conditioning systems, and mechanical ventilation. It is particularly well-suited for projects where water quality isn't a primary concern.
FEATURES
CTI Certified, ensuring unrivaled performance and consistency.
> High Efficiency Cooling
- Equipped with two-sided fully opened air intake, ensuring comprehensive air contact for superior cooling.
- Features an expansive area of infills, maximizing heat exchange efficiency for top-tier performance.
- Utilizes high frequency transverse water flow, creating strong turbulent mixing to enhance cooling efficiency significantly.
> Maximise Resource Utilization
- Designed to minimize water wastage while promoting extensive ventilation, significantly reducing energy consumption.
- Majority of components are recyclable, making it an environmentally responsible choice.
> High Impact Resistant
- Constructed with a robust and stable infills layer and internal structure, providing high impact resistance to minimize risks of damage and blockage.
> Ease to Operate & Maintain
- Built with corrosion-resistant materials, this tower is not only easy to operate and maintain but also offers lower operating costs.
MAIN PARTS
1. High Efficiency Axial Fan
> Outfitted with a renowned brand of aluminum alloy axial fan, offering high performance with lower power consumption and minimal noise.
> V-belt and pulley of superior quality, ensuring stable operation and effortless maintenance.
> Equipped with a TEFC cooling tower duty motor. Optional gear reducer, two-speed, variable-speed, or explosion-proof motors are available to suit your needs.
> Optionally upgradeable to a Permanent Magnetic Direct Drive system, this provides lower power consumption with an energy efficiency rating reaching up to IE5.
2. Uniform Water Distribution System
> Ensures even water distribution using gravity, enhancing operational efficiency.
> Non-clogging PP nozzles of large diameter offer expansive spraying coverage, avoiding blockages.
> Comes with a removable steel cover, facilitating easy checks and maintenance.
> Optional high-low flowrate nozzles maintain uniform water distribution even at low flowrates.
3. Integrated Baffle Type Infill
> Features high-quality self-extinguishing PVC infill for safety and durability.
> Integrates infill and drift eliminator, offering a larger heat exchange area, enhancing performance, and reducing drift loss to below 0.005%.
> Optional infill for high or low-temperature resistance, catering to unique operating conditions.
4. Cold Water Basin
> Automatic water system with a stainless steel mechanical float valve, known for its corrosion resistance and flexibility.
> Optional basin heater available for frost protection during colder seasons.
5. Heavy Duty & High Stability Structure
> Main structure consists of Z700 HDGS material, corrosion-resistant, and secured with 304 stainless steel bolts and nuts, ensuring robust and stable construction.
> Optional upgrade to 304 / 316 stainless steel or NWN-Armour material.
6. SMC Compressed Moulded
> Equipped with a fiberglass fan stack made from corrosion and UV-resistant material.
> Designed to enhance airflow uniformity within the tower, reducing resistance and ensuring efficient fan operation.
7. High Quality Fiberglass Panel
> Constructed with fiberglass material, ensuring corrosion and UV resistance for lasting durability.
> Premium corrugated design meticulously engineered for enhanced durability, ensuring an extended service life that keeps your system operating at peak performance.
> Choose from our elite selection of materials: robust 304 / 316 Stainless Steel or our innovative NWN-Armour, tailored to meet your specific needs and environmental demands.
8. Access Door
> Thoughtfully designed to facilitate effortless access, simplifying tower inspections and maintenance tasks, ensuring optimal functionality at all times.
9. Maintenance Platform
> Equipped with a sophisticated double layer maintenance platform, this feature enhances safety and convenience for internal cooling tower maintenance, providing ease especially during fan servicing.
10. Cage Ladder & Handrail
Product Parameters
Tower Model |
Outline dimensions (mm) |
Weight (Kg) |
NST |
W |
L |
H |
Dry |
Wet |
NST-18-A15-2A11-C1 |
3310 |
1800 |
3500 |
1030 |
2480 |
NST-20-B15-2A12-C1 |
3310 |
2000 |
3700 |
1110 |
2730 |
NST-26-D18-3A14-C1 |
4080 |
2600 |
4110 |
1660 |
4130 |
NST-30-D21-3A16-C1 |
4220 |
3000 |
4540 |
1890 |
4860 |
NST-33-E24-3A17-C1 |
4540 |
3300 |
4790 |
2080 |
5520 |
NST-35-F26-4A17-C1 |
5350 |
3500 |
4890 |
2960 |
8290 |
NST-40-F30-4B17-C1 |
5750 |
4000 |
4940 |
3310 |
9690 |
NST-43-G32-4B18-C1 |
5950 |
4300 |
5140 |
3550 |
10620 |
NST-46-H34-4B20-C1 |
6150 |
4600 |
5560 |
3900 |
11740 |
NST-48-H40-5B18-C1 |
7420 |
4800 |
5390 |
4560 |
13970 |
NST-50-I42-5B20-C1 |
7560 |
5000 |
5610 |
5190 |
15280 |
NST-54-J42-5B22-C1 |
7560 |
5400 |
6010 |
5650 |
16690 |
NST-60-J47-5B22-C1 |
8040 |
6000 |
6210 |
6330 |
19120 |
Explore the latest advancements with our NST series FRP Cooling Tower Solutions. Customized to accommodate diverse working conditions, these upgraded models deliver unmatched performance and reliability.
OPTIONS
Discover the Permanent Magnetic Direct-Driven Fan System
Innovative Energy Saving Design for Optimum Efficiency
> Experience superior efficiency with our variable frequency control, which allows low-speed operation. Achieve high efficiency and an impressive power factor for remarkable energy savings.
> Benefit from a direct-driven fan system that eliminates transmission losses. Enjoy maintenance-free operation with enhanced performance.
> Achieve outstanding power savings with an energy efficiency rating soaring to IE5, demonstrating significant power and energy conservation.
NWN-Armour Corrosion Resistant Technology
Advanced Corrosion Resistant Design for Longevity
Utilize our galvanized steel panels, enhanced with NWN-Armour's cutting-edge anti-corrosion coating. This offers corrosion resistance comparable to stainless steel, presenting a cost-effective alternative without sacrificing quality.
Additional Accessories for Enhanced Functionality
Enhance your system with our additional accessories, including PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction for superior performance and operational efficiency.
NEWIN Manufacturing Base
The Heart of Innovation: NEWIN FACTORY
Nestled in the vibrant city of Huizhou, Guangdong, our expansive manufacturing base spans a remarkable 10,000 square meters, providing ample space for cutting-edge production.
Unwavering Commitment to Quality: ISO CERTIFICATION
Proudly holding the prestigious ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, NEWIN exemplifies excellence.
Precision and Craftsmanship: WORKSHOPS
Where Strength Meets Skill: Welding Workshop
Mastering Innovation: Filler Thermoforming Workshop
The Art of Metal: Sheet Metal Processing Workshop
Bringing Concepts to Life: Cooling Tower Assembly Workshop
Ensuring Excellence: TESTING
Equipped with an Independent Testing LAB for rigorous quality checks.
Discover the Efficiency of NEWIN COOLING TOWERS:
·
Explore our versatile NWN/ NWF/ NCFN Revolutionary Closed Type Cooling Tower Series
·
Innovative NSH/ NST Dynamic Open Type Cooling Tower Series
·
NTG Robust Industrial Type Cooling Tower Series
·
NECN/NECH Advanced Evaporative Condensers
·
NWFL Efficient Dry Air Cooler
NEWIN stands ready to provide a comprehensive range of cooling tower accessories, ensuring you have the right components to maintain and upgrade towers of all sizes and types. Reach out to us for personalized accessory solutions tailored to your specific cooling tower needs.
INCLUDES:
· Comprehensive Fan Drive Systems (fan/ fan stack/reducer/motor/shaft etc.)
· Advanced Water Distribution (nozzles/ drift eliminator etc.)
· Enhanced Heat Exchange Components (PVC infills/ cooling coil etc.)
· Comprehensive Range of Other Accessories (air inlet louver/ valve etc.)
Packaging & Shipping
Open type cooling towers shipment
Closed type cooling towers shipment
Technical Strength& Standards
Certifications