Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower

Product Details
Customization: Available
Cooling Method: Cooling Tower, Cooling Tower
Certification: ISO, CE, ISO, CE, ISO, CE, SGS
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
  • Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
  • Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
  • Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
  • Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
  • Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
Find Similar Products

Basic Info.

Model NO.
NBD
Condition
New, New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Noise Level
Low
Material
PVC or PP or UPVC
Tower Shape
Round and Square
Application Fields
Counter Flow Cooling Tower
Height
160mm
Sheet Space
45/50 mm
Drift Eliminator Piece Thickness
0.8 mm
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
3926901000
Production Capacity
50000pieces/Year

Product Description

Newin V Type Series Drift Eliminator For Counter Flow Cooling Tower

Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower


Newin NBD series blade type drift eliminators is applicable to large and medium natural ventilation cooling towers and mechanical ventilation cooling towers.It can remove a large number of small water droplets carried by hot and humid air from cooling towers and avoid pollution to the surrounding environment.After installation, the water mist escape rate decreases from 0.1% when the dehydrator is not installed to 0.05%, but the eliminator has no obvious influence on the cooling water temperature.A set contains eliminator sheets and spacer, PVC rods, PVC nuts.

 

FEATURES

 
-There are different types, V type, S type, M type, mutiwave type and replacement for other brand cooling towers.

-Made of flame retardant PVC material, PP material for options if special needed.

 
-Anti-aging, high water absorption, low airflow resistance, high strength, easy installation and long service life.
 
-Easy installation with rods and screws.

Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower


PROPERTIES 
With different request in NBD drift eliminators, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Eliminator media in flame retardant or anti-bacterial execution are also available on request.

Module Length (Max)  mm 2000
Module Width  mm 500/1000
Module Depth  mm 160/175/220
Flute Height  mm 25/45/50
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 -
Sheet Thickness - Before Forming  mm 0.80
Sheet Thickness - After  Forming  mm 0.60
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details!

STRUCTURE & INSTALLATION DRAWING
Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.

Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower


APPLICATION & USAGE
Newin NBD blade drift eliminator is applicable counter flow cooling tower with SGS test in ASTM Standards to keep high quality drift eliminator to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.

Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower


FILED DATA FOR CELLUAR DRIFT ELIMINATOR REPLACEMENT
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components. 

Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower
Maybe you also interested in the below parts, for your reference
Newin V Type Series Drift Eliminator for Counter Flow Cooling Tower


Contact Person

May Zhou

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier