Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
  • Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
  • Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
  • Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
  • Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
  • Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MAN
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Round
Noise Level
Ordinary
Application Fields
Industrial
Material
PVC or PP or UPVC
Cooling Tower Type
Counter Flow Cooling Tower
Width
915/1220mm
Lenghth (mm)
1220, 1830, 2440, Any Length
Colour
Customizable
Max. Operation Temp.
80 °c (Short Time)
Max. Appllication Temp.
60 °c (Short Time)
Transport Package
20/40/40hq Container with Loose Packing
Specification
915/1220 x any length
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

MAN Series Counter flow cooling tower infill/fills: A remarkable solution engineered to enhance cooling efficiency, the MAN Series offers superior airflow and unmatched performance.

MAN Series Counter Flow Film Fill: Designed to maximize heat dissipation and optimize cooling tower efficiency, this series is an ideal choice for various industrial applications. This fill is available in both hanging or bottom-supported configurations. It features crossed corrugations that create ample surface area and promote turbulence, significantly improving heat transfer efficiency. Constructed from UV-inhibited, chemically resistant polyvinyl chloride (PVC), it boasts excellent hydrophilicity and minimal ventilation resistance. Available in widths of 915mm and 1220mm, it caters to diverse cooling tower requirements and is suitable for any counter flow cooling tower around the globe, ensuring adaptability and broad applicability.

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Features

Features

· Our Counter Flow Cooling Tower Fill boasts advanced technology and a meticulously crafted design to deliver exceptional cooling effects.
· Experience unparalleled ventilation with minimal resistance. Its extraordinary hydrophilicity ensures a vast contact area with effective film formation. This results in excellent heat conductivity and outstanding chemical stability, with resistance to acids, alkalis, and organic solvents.
· Crafted from a staggered ring material that can be assembled at a 60° angle, our fill offers versatility with materials such as polyvinyl chloride (PVC) and polypropylene (PP) to suit your specific needs.



Picture in detail

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Parameter

Properties

At Newin (Guangdong) Machinery Co., Ltd., we understand the diverse needs in MAN film fill specifications, including variations in length, width, materials, or thickness. We invite you to share your specific requirements with us, ensuring we provide a precise solution and competitive offer tailored to your needs. Our comprehensive offerings include fill media options in flame retardant or anti-bacterial versions, available upon request, showcasing our commitment to covering all customer requirements.
Module Length (Max.)  mm 3660
Module Width   mm 915 / 1220
Module Depth   mm -
Flute Height  mm 19
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.38
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing

Newin is dedicated to providing complete support, offering detailed structure and installation drawing guidance. We include jobsite storage advice and a meticulous quality control report with each shipment to ensure our customers are well-informed upon receipt of their materials. Additionally, we offer OEM services and special mold designs upon request, demonstrating our flexibility and commitment to customer satisfaction.Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Application

Application & Usage

Newin MAN Film Fill is designed to seamlessly integrate with various counter flow cooling tower series, including renowned brands such as MD, CP, MC Series among others globally. With SGS-certified quality, our fills ensure peak efficiency for your cooling towers. Provide us with your tower model or dimensions, and we'll calculate the precise number of sheets required for optimal replacement.
Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency

Applicable Commercial Standards

The material for the sheets is rigorously tested according to SGS and adheres to ASTM standards. We offer the ability to test each specific property or all properties of your products upon request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Counter Flow Film Fill Replacement

Input the measurement data below for your maintenance or repair projects. Trust in Newin for superior quality and dependability. Whether you need a site visit or maintenance service, our solutions are engineered to fit your cooling tower fills or components perfectly.
Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Options

You May Also Find These Interesting: Discover an array of intriguing offerings that complement our Counter Flow Cooling Tower Fill, each tailored to enhance performance and deliver excellence in every application.

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
NEWIN Manufacturing Base

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
NEWIN FACTORY
Embark on an inspiring journey through our state-of-the-art manufacturing base, strategically nestled in the heart of Huizhou's vibrant industrial hub, Guangdong. Spanning a vast 10,000 square meters, this facility is a beacon of innovation, excellence, and cutting-edge technological advancements.

ISO CERTIFICATION
We proudly highlight our unwavering commitment to supreme quality and environmental stewardship with our prestigious ISO certifications: ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, setting the gold standard for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unparalleled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously crafted to deliver top-tier performance and unmatched reliability. Each model embodies the pinnacle of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the extraordinary capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new benchmarks in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and peak efficiency, optimizing every facet of cooling for outstanding results.

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit an array of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories for optimal performance.

CONTAIN:
· A robust fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Discover the pinnacle of secure conveyance with our exquisitely engineered open-type cooling towers. Each tower is meticulously encased using premium materials coupled with sophisticated packing techniques, assuring their arrival in pristine condition. Our unwavering dedication to safety and security shields your investment from any potential transit harm. Enjoy the benefits of our efficient logistics and punctual delivery schedule, crafted to ensure your cooling solutions are operational without a moment's delay.

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Closed type cooling towers shipment: Revel in the assurance provided by our unparalleled packaging solutions for closed-type cooling towers. Each unit is robustly and carefully housed to withstand the rigors of transport, guaranteeing they arrive in perfect condition and are immediately operational. Our relentless focus on quality control and swift shipping empowers you to concentrate on leveraging our state-of-the-art cooling technology to meet your specific requirements, liberating you from any logistical concerns.
Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Technical Strength& Standards

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency
Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency

Certifications

Counter Flow Cooling Tower Fill for Maximum Airflow and EfficiencyCounter Flow Cooling Tower Fill for Maximum Airflow and EfficiencyCounter Flow Cooling Tower Fill for Maximum Airflow and EfficiencyCounter Flow Cooling Tower Fill for Maximum Airflow and Efficiency

Counter Flow Cooling Tower Fill for Maximum Airflow and Efficiency





Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More