Product Details
Customization: Available
Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
  • Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
  • Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
  • Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
  • Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
  • Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NTG
Noise Level
Ordinary
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
800-5000ton
Inlet Water Temperature
43 Deg.C
Outlet Water Temperature
33 Deg.C
Wet Bulb Temperature
28 Deg.C
Air Flow
2400 Km3/H
Transport Package
40 Container Loading Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
841950
Production Capacity
15000 Sets/Year

Product Description

NTG Cooling Tower Cooling Capacity from 800tons to 5000tons per cell

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Product Description

NEWIN INDUSTRIAL COOLING TOWERS!
Cooling capacity from 800tons to 5000tons per cell, multi-cells are available, widely used in industries of Electric Power, Petroleum, Chemical Fertilizer, Sugar, Smelt, Seawater cooling etc.

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

Features

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

NEW! NTG Cooling Tower Solution

1. High Efficient Fan Drive System
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
> FRP Fan Blades feature limosis- type designs, offering a lightweight structure, exceptional strength, excellent corrosion resistant and outstanding interchangeability for superior performance.
Prior to leaving the factory, the fan's impeller is subjected to a static balance test, guaranteeing the flawless balance quality of its rigid rotor G6.3.
 
> NCJ Gear Reducer effectively addresses the issue of transmission shaft failure. The installation is incredibly convenient, requiring no calibration of the transmission shaft. It leads to a 5%-10% reduction in energy consumption and a remarkable 50% decrease in vibration.
Fan Motor utilizes a big brand asynchronous motor designed for outdoor use. Insulation grade: F; Protection grade: IP55. 
The enhanced design of the motor seat adjustment ensures increased safety and reliability.
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
 
2. SMC Fan Stack
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
The fan stack of F.R.P material is crafted using the sophisticated SMC molding process, featuring energy-efficient, strong strength, durable service, anti- vibration design, anti-UV and nice appearance.

Energy Efficient

The Newin Company has meticulously refined the kinetic energy recycling fan stack to be highly energy-efficient, successfully eliminating the issue of airflow detachment from walls and minimizing vortex formation.

The negative pressure zone at the center of the fan stack has been significantly reduced, resulting in a more uniform distribution of fracture surface wind speed at the fan stack outlet. Additionally, during the molding process of the fan stack, painting resin is applied twice to further minimize resistance on the inside surface.

3. Drift Eliminator
The highly effective drift eliminator is intricately constructed with a V-shaped louver design and meticulously assembled with rod accessories, showcasing minimal wind resistance.

High Efficiency Of Drift Water Recovery: water loss value is a mere 0.005% or less.
Low Resistance& Energy Conversation: In an air wind condition of 3.0m/s, the ventilation resistance loss measures only 0.8mm H2O.

Water Conservation: Significantly minimize the depletion of drift water, decrease the amount of added water and the dosage of additives. Simultaneously, mitigate the impact of drift water to its minimum level.
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

4. Uniform Water Distribution
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
A network of branch-pipe water distribution system is employed, featuring strategically positioned umbrella type nozzles on branch pipes to achieve the most effective dispersion of water.

Umbrella Type Nozzle is resistant to blockages and successfully resolved issues such as water film emergence and low indenter during operation due to its special innovative design.
Flexibility Of Water Distribution: The system exhibits high adaptability to hydraulic loading, as it can still operate even when subjected to a loading of 130% under working conditions. Furthermore, reducing the loading to 60% does not have any impact on the distribution.

Ease Of Maintenance: This type of down spray ensures that water is distributed to the lowest points of the system, preventing ponding and dirt buildup. It eliminates the need for manual cleaning of the distribution pipe. If turbidity does not exceed 300ppm, it can operate continuously. The injection-molded nozzles offer strong interchangeability and easy installation and removal, facilitating maintenance of the distribution system.

5. NTF Trickle Filling
NTF trickle filling combines the characteristics of splash filling and film filling, maximizing the cooling effect in poor water conditions by creating a delicate dripping water layer.

> High quality PP materialexcellent resistance to high temperatures and chemical corrosion compared to PVC, resulting in a longer lifespan.

> The special grid structure design further enhances the dispersion of spray water, thereby optimizing heat exchange efficiency.


Simple Mechanical Assembly, Safety& Environmental Protection: The trickle fills boasts a high-stability structure achieved through simple mechanical assembly, obviating the need for adhesive packing. This not only guarantees safety and environmental friendliness but also markedly diminishes assembly time.



 
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

6. FRP Components
The utilization of FRP ( Fiberglass Reinforced Plastic) components are crafted from top-notch raw and auxiliary materials, boasting vibrant hues and exceptional longevity. Adhering to the stringent manufacturing and testing standards outlined in GB/T7190-2008 for FRP pultruded structural components in FRP cooling towers, these products have undergone rigorous evaluation by national authoritative institutions, surpassing or meeting all quality benchmarks set at a national level.
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per CellTechnical index:
Items Parameter index Remarks
Barcol hardness >36 There are no more than three bubbles with a diameter of 2-3mm within 1m2 on the surface of FRP, and the maximum diameter of any bubble on the surface does not exceed 3mm.
Bending strength ≥150Mpa
Tensile strength ≥200MPa
Impact toughness ≥20J/cm2
Degree of cure ≥85%
Resin content 55%
High resin content ≥70%

6. Maintenance Platform
  1. The overhaul walkway provides convenient access to the cooling tower.
  2. The fan is equipped with maintenance platforms and safety guardrails to facilitate the inspection and upkeep of the fan drive system.
  3. The cooling tower is equipped with access stairs for ease of regular maintenance at the top of the tower and to meet fire protection regulations.
7. Anti-corrosion Design
The prevention of equipment corrosion is a critical factor in maintaining the quality of cooling towers. In traditional cooling tower design, the internal components are typically constructed from steel, posing a persistent challenge in terms of corrosion. While the concrete frame of large cooling towers generally has a lifespan of approximately 50 years, high-performance anti-corrosion steel parts only have a significantly shorter lifespan of around 15 years. Therefore, our company primarily utilizes non-metallic materials for internal components such as fillers, nozzles, and water collectors, all crafted from plastic. Additionally, the fan stack and wind resistant plate are made from F.R.P to ensure durability with a lifespan exceeding 20 years and reduced maintenance costs. Furthermore, small steel components undergo rigorous anti-corrosion treatment using hot-dip galvanizing technology.

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Product Parameters

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
NTG Dimension
(mm)
Fan Weight (kg)
Model L W H Diameter
(mm)
Dry Wet
NTG-3030-47-330-C1 7500 7500 7200 4700 16730 20250
NTG-3636-55-330-C1 9000 9000 8550 5500 20960 26140
NTG-4242-60-330-C1 10500 10500 9550 6000 25120 32400
NTG-4848-77-330-C1 12000 12000 9850 7700 31240 42220
NTG-5454-80-330-C1 13500 13500 10650 8000 35990 49820
NTG-6060-85-330-C1 15000 15000 12250 8500 40830 57840
NTG-6464-92-330-C1 16000 16000 12600 9200 45030 64210
NTG-7070-92-330-C1 17500 17500 13500 9200 50160 74600
NTG-7474-103-330-C1 18500 18500 14500 10360 55430 83420
 
NEWIN Manufacturing Base

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
NEWIN FACTORY 
Manufacturing base Situated In Huizhou, Guangdong. It Covers An Area Of 10,000 Square Meters.

ISO CERTIFICATION
ISO9001:2015 Quality Manergement System Certification ISO14001:2015 Environmental Manergement System Certification

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Closed Type Cooling Tower Series
· NSH/ NST Open Type Cooling Tower Series
· NTG Industrial Type Cooing Tower Series
· NECN/NECH Evaporative condenser
· NWFL Dry Air Cooler

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
NEWIN manufactures and stocks all major cooling tower accessories to meet maintenance and replacement needs of almost any size and types of cooling tower. Please contact us to customize the cooling tower accessories you need. 

CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange(PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
 
Packaging & Shipping

Open type cooling towers shipment

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Closed type cooling towers shipment
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Technical Strength& Standards

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell
Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

Certifications

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per CellNtg Cooling Tower Cooling Capacity From 800tons to 5000tons Per CellNtg Cooling Tower Cooling Capacity From 800tons to 5000tons Per CellNtg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

Ntg Cooling Tower Cooling Capacity From 800tons to 5000tons Per Cell

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier