Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
  • Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
  • Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
  • Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
  • Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
  • Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Find Similar Products
  • Overview
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MAH
Condition
New
Ventilation Mode
Mechanical Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Noise Level
Low
Application Fields
Industrial
Material
PVC or PP or UPVC
Thickness
0.32-0.38 mm
Temperature
-20 Deg C to 65 Degc
Usage
for Refrigerate
Fill Material
PVC or PP or UPVC
Absorption Rate
< 0.015%
Drift Water Loss Rate
<0.001%
Mold Size
618mm
Width
760/915/1020/1220/1320/1520 mm
Sheet Space
19mm
Transport Package
20/40/40hq Container
Specification
760/915/1020/1220/1320/1520 x any length
Trademark
NEWIN
Origin
China
HS Code
3926901000
Production Capacity
1000000mt Per Year

Product Description

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill

Newin MAH Film Fill is a hanging film type cooling tower fill which incorporates highly efficient cellular drift eliminator and molded with the air inlet louver, spreads the water through the thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow to get higher cooling efficiency. This type of fill provides much more water surface exposure per cubic foot than splash type fill.


FEATURES

-Applicable for cross flow type cooling towers
- Hanging or glue is available
- Incorporates highly efficient cellular drift eliminators, intergrally molded within the fill sheet
- Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow
-Thermoformed from PVC with a flame spread rating and considered self extinguishing

Specification
With different request in MAH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max)  mm 3708
Module Width  mm 760/915/1220/1320/1520
Module Depth  mm -
Flute Height  mm 19
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.38
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details!
 
Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs


Structure & Installation Drawing
Newin supply structure & installation drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materials. OEM or special mold design also available on request.

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
MAH Infill Pictures --- cooling tower cross flow film fill 

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill


APPLICATION & USAGE
Newin MAH Film Fill is applicable for Marley cooling tower series of NCNX,QUADRA FLOW, AQUATOWERAV600 Field Erected, with SGS test in ASTM Standards to keep high quality infill to get the high efficienty of cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Filed Data For Cross Flow Film Fill Replacement
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components.

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill

maybe you will interest in other parts, please visit to our website: newinmachine.en.made-in-china.com

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
NEWIN Manufacturing Base

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
NEWIN FACTORY
Discover the expansive manufacturing base of NEWIN, nestled in the industrial heartland of Huizhou, Guangdong. This state-of-the-art facility spans a sprawling 10,000 square meters, dedicated to excellence in every facet of production.

ISO CERTIFICATION
NEWIN proudly upholds the highest standards with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, ensuring impeccable quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Revolutionary Closed Type Cooling Tower Series, engineered for optimal efficiency and performance.
· NSH/ NST Innovative Open Type Cooling Tower Series, designed for versatility and reliability in diverse applications.
· NTG Robust Industrial Type Cooling Tower Series, crafted for heavy-duty cooling solutions.
· NECN/NECH Advanced Evaporative Condenser, for superior thermal management and energy efficiency.
· NWFL Efficient Dry Air Cooler, offering reliable performance in varied cooling requirements.

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
At NEWIN, we manufacture and maintain an extensive inventory of essential cooling tower accessories, ready to meet the diverse maintenance and replacement needs for any size or type of cooling tower. Reach out to us for customized solutions tailored to your specific requirements.

CONTAIN:
· Comprehensive Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Advanced Water Distribution Components (featuring nozzles, drift eliminator, etc.)
· Superior Heat Exchange Elements (such as PVC infills, cooling coil, etc.)
· Additional Accessories (including air inlet louver, valve, etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Ensuring the safe and secure delivery of our remarkable open type cooling towers, we meticulously package each unit to withstand the rigors of transport. Our commitment to excellence extends beyond manufacturing to include reliable shipping solutions, ensuring your equipment arrives in pristine condition.

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Closed Type Cooling Towers Shipment: We take immense pride in our thoughtful shipping process for closed type cooling towers. Each unit is packaged with precision and care, guaranteeing that it reaches its destination intact and ready for seamless integration into your operations. Trust in our dedicated approach to deliver not just a product, but a promise of quality.
Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Technical Strength& Standards

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill
Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill

Certifications

Marley Cross Flow Cooling Tower Filling/Cooling Tower InfillMarley Cross Flow Cooling Tower Filling/Cooling Tower InfillMarley Cross Flow Cooling Tower Filling/Cooling Tower InfillMarley Cross Flow Cooling Tower Filling/Cooling Tower Infill

Marley Cross Flow Cooling Tower Filling/Cooling Tower Infill

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier