Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
  • Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
  • Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
  • Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
  • Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
  • Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MAN
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Round
Noise Level
Ordinary
Application Fields
Industrial
Material
PVC or PP or UPVC
Cooling Tower Type
Counter Flow Cooling Tower
Width
915/1220mm
Lenghth (mm)
1220, 1830, 2440, Any Length
Colour
Customizable
Max. Operation Temp.
80 °c (Short Time)
Max. Appllication Temp.
60 °c (Short Time)
Transport Package
20/40/40hq Container with Loose Packing
Specification
915/1220 x any length
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

MAN Series Counter Flow Cooling Tower Infill/Fills

MAN Series Counter Flow Film Fill This innovative design offers a versatile choice of either hanging or bottom-supported configuration, featuring crossed corrugations that significantly amplify surface area and turbulence for superior heat transfer efficiency. Crafted from UV-inhibited, chemically resistant polyvinyl chloride (PVC), our product stands out with exceptional hydrophilicity and minimal ventilation resistance. With available widths of 915mm and 1220mm, it seamlessly adapts to the diverse demands of various cooling towers. Universally applicable, it is engineered to enhance performance in any counter flow cooling tower across the globe.

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Features

Features

· Harnessing cutting-edge technology and a well-thought-out design, our cooling towers promise an exceptional cooling effect that stands out in the industry.
· Exemplary ventilation is paired with minimal resistance, ensuring robust hydrophilicity and expansive contact areas. Our fills boast superb film formation, facilitating easy packing and remarkable heat conductance. Enjoy unparalleled chemical stability with superior resistance to acids, alkalis, and organic solvents.
· Our staggered ring material configuration is ingeniously assembled, with packing generally set at a 60° angle. Choose between two premium packing materials: polyvinyl chloride (PVC) and polypropylene (PP), tailored to meet your specific cooling needs.



Picture in detail

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Parameter

Properties

Our MAN fill media is highly customizable to meet your specific needs. Whether you require unique dimensions, materials, thickness, or other specifications, simply share your detailed requirements with us. Newin is dedicated to fulfilling all customer demands, ensuring your satisfaction. For added versatility, we offer fill media with flame-retardant or anti-bacterial properties. Just let us know your preferences, and we'll provide the most accurate solutions and competitive offers tailored to your needs.
Module Length (Max.)  mm 3660
Module Width   mm 915 / 1220
Module Depth   mm -
Flute Height  mm 19
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.38
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing

Newin provides comprehensive support with structure and installation drawings, complete with practical jobsite storage advice and thorough quality control reports, all delivered alongside your shipment. We ensure you receive everything you need for a seamless experience. Additionally, we offer OEM services and can accommodate special mold designs upon request, tailoring our products to your exact preferences.Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Application

Application & Usage

The versatile Newin MAN Film Fill effortlessly integrates with a wide array of counter flow cooling tower series from various renowned brands, such as MD, CP, MC Series and many more globally recognized models. Our products undergo rigorous SGS testing to ensure unparalleled quality and maximize the cooling tower's performance. Simply provide us with your tower model or dimensions, and we will expertly calculate the required number of sheets for an optimal replacement.
Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency

Applicable Commercial Standards

The materials used in our sheets are meticulously tested according to SGS standards utilizing ASTM protocols. Each specific property, or a comprehensive analysis of all properties, is accessible upon request, ensuring your products meet the highest industry standards.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Field Data for Counter Flow Film Fill Replacement

Please provide the measurement data below to ensure your cooling tower maintenance or repair projects uphold the highest standards of quality and reliability. Trust Newin for expert site visits and maintenance services, engineered to seamlessly fit your cooling tower fills and components.
Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Options

Other Fascinating Finds You Might Like:

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
NEWIN Manufacturing Base

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
NEWIN FACTORY
Embark on an inspiring journey to our cutting-edge manufacturing complex, perfectly situated in Huizhou, Guangdong—a bustling industrial epicenter. Spanning a vast 10,000 square meters, our facility epitomizes innovation, excellence, and forward-thinking technological advances.

ISO CERTIFICATION
We proudly highlight our steadfast dedication to superior quality and environmental responsibility through our esteemed ISO certifications: the ISO9001:2015 Quality Management System and the ISO14001:2015 Environmental Management System, setting the industry benchmark.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Embrace the pinnacle of efficiency and innovation with our Closed Type Cooling Tower Series, precisely engineered for top-tier performance and unmatched dependability. Each model resonates with the forefront of cooling tower technology.
· NSH/ NST Uncover the steadfast reliability of our Open Type Cooling Tower Series, masterfully crafted for superior operation and durable performance, setting industry standards and exceeding expectations in sustained excellence.
· NTG Unveil the impressive capabilities of our Industrial Type Cooling Tower Series, uniquely designed to tackle heavy-duty and challenging applications, ensuring durability and strength at every junction.
· NECN/NECH Integrate top-tier efficiency effortlessly with our advanced Evaporative Condenser models, establishing pioneering standards in performance and operational brilliance, transforming the cooling landscape.
· NWFL Tap into the power of cutting-edge technology with our Dry Air Cooler, meticulously designed for excellent airflow and peak efficiency, optimizing each aspect of cooling for unparalleled outcomes.

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
NEWIN is your reliable partner for exceptional cooling tower solutions, presenting a broad array of accessories to meet your upkeep and replacement needs. Customize your selection to suit a diverse range of cooling tower sizes and types. Reach out to us to personalize the ideal suite of accessories for your cooling tower, ensuring optimal performance.

CONTAIN:
· A durable Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, designed for resilience and accuracy, ensuring smooth operation.
· Exceptionally efficient Water distribution components, featuring precisely crafted nozzles and advanced drift eliminators for excellent performance, optimizing water control.
· Superior Heat exchange options, boasting top-grade PVC infills and cooling coils, engineered for optimal functionality and energy efficiency, enhancing thermal management.
· Additional vital accessories, such as air inlet louvers and valves, to seamlessly finalize your system, boosting overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Embark on a journey of secure and seamless transportation with our premier open-type cooling towers. Every single tower is scrupulously packaged using premium-grade materials and cutting-edge packing techniques to ensure their flawless arrival. Our unwavering dedication to safety and protection shields your investment from any potential transit mishaps. Revel in our streamlined logistics and punctual delivery service, meticulously orchestrated to have your cooling solutions operational without a hitch, ensuring zero downtime.

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Closed type cooling towers shipment: Revel in the unparalleled confidence that comes with our exceptional packaging solutions for closed-type cooling towers. Each unit is diligently and robustly encased to withstand the rigors of transportation, guaranteeing arrival in pristine condition and ready for peak performance. Our steadfast commitment to rigorous quality control and prompt delivery allows you to concentrate on leveraging our state-of-the-art cooling technology tailored to your unique requirements, leaving logistical concerns behind.
Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Technical Strength& Standards

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency
Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency

Certifications

Counter Flow Cooling Tower Fills for Optimal Air Contact EfficiencyCounter Flow Cooling Tower Fills for Optimal Air Contact EfficiencyCounter Flow Cooling Tower Fills for Optimal Air Contact EfficiencyCounter Flow Cooling Tower Fills for Optimal Air Contact Efficiency

Counter Flow Cooling Tower Fills for Optimal Air Contact Efficiency





Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More