Elevate your cooling tower's performance with the cutting-edge EVL Cooling Tower Air Inlet Louver.
The Newin EVL Series Air Inlet Louver is a masterpiece of engineering crafted from high-strength PVC sheets, meticulously bonded for outstanding durability. The surrounding frame comes in your choice of robust galvanized steel or elegant stainless steel, providing long-lasting resilience. Featuring an innovative honeycomb inlet grille, this advanced design enhances airflow efficiency, expertly filters impurities, and prevents water splash. By safeguarding against potential icing, water damage, and unnecessary water losses, the EVL air inlet louver ensures optimal performance and reliability for your cooling tower system.
Features
Features
- Enhance airflow seamlessly into the cooling tower, ensuring optimal performance and efficiency.
- Effectively guard against debris infiltration, maintaining system cleanliness and functionality.
- Mitigate the splash and escape of water droplets, safeguarding surrounding environments.
- Limit sunlight exposure within the cooling tower to significantly reduce algae proliferation.
- Dramatically lower noise emissions from the tower, promoting a quieter and more pleasant environment.
- Achieve impressively low pressure drop results, enhancing overall system efficiency.
- Facilitate hassle-free installation, paired with easy access for routine cleaning and maintenance.
- Versatile application across a broad spectrum of new installations and upgrades, including air inlets
for both compact and expansive field-erected counter flow and straight-sided cross flow towers, fresh air make-up systems, air pollution control scrubbers, and VOC strippers.
Parameter
Distinctive Properties: Explore the unique features that set our products apart, ensuring exceptional performance and reliability.
Tailor Your EVL Air Inlet Louver: At Newin, we accommodate a variety of customization requests for EVL air inlet louvers, including dimensions, materials, and thickness. Communicate your specific requirements to receive a personalized solution and competitive offer. Newin adeptly fulfills all customer demands. We offer fill media in flame-retardant or anti-bacterial compositions upon request, ensuring your safety and satisfaction.
Module Length (Max) |
mm |
2440 |
Module Width (Max) |
mm |
800 |
Module Thickness |
mm |
80 |
Flute Height |
mm |
25 |
Sheet Thickness - Before Forming |
mm |
0.5 |
Sheet Thickness - After Forming |
mm |
0.4 |
Max. application temp. (short time) - PVC |
°C |
60 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Blueprint: Gain insights into our comprehensive structure and installation blueprints, designed for seamless project execution.
Comprehensive Support & Quality Assurance: Newin provides detailed structure and installation guidance, jobsite storage recommendations, and a thorough quality control report with every shipment, ensuring our clients are well-prepared upon receiving materials. We offer OEM solutions and custom mold designs to meet specific project needs, upon request.

Application
Application & Usage
The Newin EVL air inlet louver is specifically designed for use in counter flow cooling towers. With a commitment to excellence, it adheres to the stringent SGS testing under ASTM Standards, ensuring premium quality infill for superior cooling tower efficiency. Simply provide us with your tower's model or dimensions, and we will expertly estimate the perfect air inlet louver size for your cooling tower's replacement needs.
Applicable Commercial Standards
The sheet material for our products is precisely tested under the stringent SGS guidelines following ASTM standards. Each characteristic, or all attributes, can be evaluated upon request to meet your product's specific needs.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Filed Data for Cross Flow Film Fill Replacement
For maintenance of your cooling tower or repair projects demanding top-notch quality and dependability, trust Newin for a site visit or professional maintenance service. Our solutions are designed to seamlessly integrate with your cooling tower fills or components, ensuring optimal performance.

NEWIN Manufacturing Base

NEWIN FACTORY
Our state-of-the-art manufacturing base, nestled in the vibrant and industrious region of Huizhou, Guangdong, proudly extends over an impressive 10,000 square meters. This expansive facility serves as a robust foundation for pioneering innovation and achieving outstanding excellence in our field.
ISO CERTIFICATION
Proudly adhering to the industry's highest standards, our prestigious certifications include ISO9001:2015 for exceptional Quality Management and ISO14001:2015 for our unwavering commitment to leading Environmental Management practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Explore our state-of-the-art Closed Type Cooling Tower Series, expertly engineered to deliver precision, maximum efficiency, and superior performance.
·
NSH/ NST Introducing our meticulously designed Open Type Cooling Tower Series, crafted to ensure optimal performance and unwavering reliability every time.
·
NTG Discover our Industrial Type Cooling Tower Series, skillfully crafted to meet the rigorous and demanding needs of industrial applications.
·
NECN/NECH Our exceptional Evaporative Condenser guarantees superior cooling efficiency and outstanding performance, setting new benchmarks in the industry.
·
NWFL Our Dry Air Cooler series stands as a beacon of cutting-edge design and unparalleled energy efficiency, setting new standards in cooling technology.
NEWIN is your trusted partner in providing a comprehensive range of cooling tower accessories. We not only stock but also manufacture components to support maintenance and replacements for virtually any size or type. Reach out to us to tailor the perfect accessories that precisely meet your specific requirements.
CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange (PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: Embark on an extraordinary journey of shipping excellence with our meticulously designed open type cooling towers. Crafted to surpass the highest safety and reliability benchmarks, these towers promise seamless integration into your operations. Our highly skilled logistics team curates an impeccable delivery process, guaranteeing your order reaches you swiftly and precisely, right where you need it. Trust us to elevate your delivery experience to a new standard of perfection, ensuring unparalleled satisfaction.
Closed Type Cooling Towers Shipment: Experience the pinnacle of shipping sophistication with our closed type cooling towers, expertly encased to maintain their pristine integrity. We ensure that each unit traverses its journey with flawless security and punctuality, safeguarding the unparalleled performance and quality that define our elite cooling systems. From our factory to your hands, rely on our extensive expertise to provide a streamlined, worry-free shipping experience, instilling assurance and trust at every turn.
Technical Strength& Standards

Certifications