Cooling Method: | Counter Flow |
---|---|
Ventilation Mode: | Forced Draft |
Material: | Metal |
Air Contact Form: | Wet |
Air Contact Way: | Open |
Tower Shape: | Square |
Customization: |
---|
Suppliers with verified business licenses
|
NCF series cooling tower is all-metal construction, casing is made of zinc magnesium aluminum or stainless steel plate, equiped with low noise multi-wheel centrifugal fans. The fan and its driven system are installed at the bottom of cooling tower, it easily makes to control the noise level, and avoided the corrosion caused by saturated moisture, ensured longer service life and facilitated cooling tower of daily maintenance work. Closed water basin can effectively isolated direct sunlight to the cooling water, effectively controlled the algae bacteria breeding and avoid causing bacteria "veterans" |
Beautiful appearance, flexible combination, high thermal efficiency, small footprint , environmental protection, low noise, easy maintenance, long service life.
Using closed cooling tower dedicated motor, IP55 protection grade, insulation class is F, suitable for hot and humid environment to run for a long time. Products comply with IEC international standards, with high efficiency, low noise, long life, reliable operation, etc.
Centrifugal fan
Using the centrifugal fan, through static and dynamic test of production process, to meet the cooling tower heat transfer performance under the premise of maximum noise reduction.
Using the high quality of modified PVC materials, the heating vacuum forming the diaphragm of the wet packing, with uv resistance, chemical resistance, changing the characteristics of high thermal efficiency.
Using the high quality steel plate thickness profile, supporting the various pipeline interface, outlet is also equipped with filter, hydrating mouth built-in brass valves, large diameter plastic floating ball, automatically adjust the water level, water plate design for large capacity, high water level.
Item | Water flow (m³/h) |
Power (Kw) |
Dimension (mm) |
Inlet pipe diameter (mm) |
Outlet pipe diameter (mm) |
Weight (kg) | |||
Model | Length | Height | Dry | Wet | |||||
NCF-100 | 100 | 11 | 2800 | 4350 | 200 | 200 | 2200 | 5300 | |
NCF-125 | 125 | 15 | 2800 | 4350 | 200 | 200 | 2200 | 5300 | |
NCF-135 | 135 | 18.5 | 2800 | 4350 | 200 | 200 | 2200 | 5300 | |
NCF-150 | 150 | 22 | 2800 | 4710 | 200 | 200 | 2200 | 5300 | |
NCF-165 | 165 | 22 | 2800 | 4950 | 200 | 200 | 2200 | 5300 | |
NCF-180 | 180 | 22 | 3800 | 4350 | 200 | 200 | 3350 | 7200 | |
NCF-200 | 200 | 22 | 3800 | 4710 | 200 | 200 | 3350 | 7200 | |
NCF-220 | 220 | 30 | 3800 | 4710 | 200 | 200 | 3350 | 7200 | |
NCF-235 | 235 | 30 | 3800 | 4950 | 200 | 200 | 3350 | 7200 | |
NCF-250 | 250 | 37.5 | 3800 | 4950 | 200 | 200 | 3350 | 7200 | |
NCF-265 | 265 | 18.5x2 | 5480 | 4350 | 250 | 250 | 5050 | 11800 | |
NCF-290 | 290 | 18.5x2 | 5480 | 4710 | 250 | 250 | 5050 | 11800 | |
NCF-305 | 305 | 18.5x2 | 5480 | 4710 | 250 | 250 | 5050 | 11800 | |
NCF-325 | 325 | 18.5x2 | 5480 | 4950 | 250 | 250 | 5050 | 11800 |
|
Very quiet operation Centrifugal fan with low noise characteristics, especially suitable for the requirements of low noise and external static pressure occasions. In addition, since the noise generated by the ventilator is directional, the noise problem is avoided by moving the unilateral inlet end of the unit away from the noise sensitive area. If need more quiet operation, centrifugal ventilator unit can be equipped with other noise elimination options. |
Indoor installations NCF series cooling tower can be installed indoors, usually requiring air ducts in and out of the unit. The design of the air duct shall be symmetrical to ensure uniform air intake and exhaust of the unit.Requirements:A.The static pressure loss in the duct shall not exceed 125Pa, and the maximum external static pressure of 125Pa can be overcome by increasing a ventilator motor.B.When the installation of air duct, must choose a solid bottom plate, should also use partition plate to replace the side of the air into the net cover.C.In the air duct should be the roommate access door to facilitate the maintenance of fan drive components and water distribution system. |
|
Jo.h Zhu Sales Manager For cooling tower information please visit to newinmachine.en.made-in-china.com For cooling tower parts information please visit to newinmachine.en.made-in-china.com |