CTI Certificated Cross Flow Open Type Cooling Tower FRP

Product Details
Customization: Available
Cooling Method: Cross Flow
Ventilation Mode: Mechanical Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • CTI Certificated Cross Flow Open Type Cooling Tower FRP
  • CTI Certificated Cross Flow Open Type Cooling Tower FRP
  • CTI Certificated Cross Flow Open Type Cooling Tower FRP
  • CTI Certificated Cross Flow Open Type Cooling Tower FRP
  • CTI Certificated Cross Flow Open Type Cooling Tower FRP
  • CTI Certificated Cross Flow Open Type Cooling Tower FRP
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NST series
Material
FRP
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO, CTI
Condition
New
Applications
Industrial Water Enhance Cooling/ HVAC etc
Water Pump Motor
IP55/ IP65, Insulation Class F
Character
Energy Saving and Easy Maintainance
Drift Loss
Less 0.002%
Structure
Hdgs/ Ss/ FRP and So on
Casing/ Body
Hdgs/ Ss/ FRP and So on
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
841989
Production Capacity
15000 Sets / Year

Product Description

CTI Certificated Cross Flow Open Type Cooling Tower FRP

CTI Certificated Cross Flow Open Type Cooling Tower FRP
Product Description

NST series is a cross-flow design, induced draft open-loop cooling tower commonly utilized in small and medium industrial, air-conditioning, and mechanical ventilation systems as well as projects with lower water quality requirements.

CTI Certificated Cross Flow Open Type Cooling Tower FRP

FEATURES
CTI Certified, Performance Ensurance

> High Efficiency Cooling
- Two-sided fully opened air intake for thorough air contact.
- Large area of infills for higher heat exchange efficiency.
- High frequency transverse water flow for strong turbulent mixing and higher cooling efficiency.

> Maximise Resource Utilization
- To minimize the water wastage, promote extensive ventilation to reduce energy consumption.
- Majority of the materials are recyclable to further protect the environment.

> High Impact Resistant
- The infills layer and internal structure are rigid and stable with high impact resistance, to reduce the risk of infills damage & blockage.

> Ease to Operate & Maintain
- Main structure with corrosion resistant properties, easy to operate and maintain, with lower operating cost.




 MAIN PARTS
 
CTI Certificated Cross Flow Open Type Cooling Tower FRP


1. High Efficiency Axial Fan
> Well-known brand of aluminum alloy axial fan, high performance, lower power consumption and low noise.
> Better quality of V-belt and pulley, stable operation and easy maintenance.
> TEFC cooling tower duty motor. Optional gear reducer is available. Optional two speed, variable speed or explosion proof motor are available.
> Optional to upgrade the motor to Permanent magnetic direct drive system, lower power consumption with energy efficiency rating up to IE5.


2. Uniform Water Distribution System
> Evenly distribute the water by gravity.
> Large diameter, non-clogging PP nozzles with wide spraying coverage.
> Removable steel cover, easy to check and maintain.
> Optional high-low flowrate nozzles (ensure uniform water distribution even at low flowrate).

3. Integrated Baffle Type Infill
> High quality self-extinguishing PVC infill.
> Integral formation infill and drift eliminator. Higher heat exchange area with high performance drift eliminator to achieve better heat exchange performance, and reduce the drift loss below 0.005%.
> Optional for high temperature or low temperature resistant infill, to fulfill special operating condition.

4. Cold Water Basin
> Automatic make up water system uses a stainless-steel mechanical float valve, which is corrosion resistant and highly flexible.
> According to the needs of frost protection during cold seasons, a water basin heater can be installed.


 
5. Heavy Duty & High Stability Structure
> The main structure is made of Z700 HDGS corrosion-resistant material, secured with 304 Stainless Steel bolts and nuts, making it robust and stable.
> Optional 304 / 316 Stainless Steel or NWN-Armour material is available.

6. SMC Compressed Moulded
> Fiberglass Fan Stack Fiberglass material, corrosion resistant and UV resistant.
> Enhances airflow uniformity within the tower and reduces airflow resistant. Ensures efficient operation of the fan.

7. High Quality Fiberglass Panel
> Fiberglass material, corrosion resistant and UV resistant.
> Corrugated design for enhanced durability and prolong the service life.
> Optional 304 / 316 Stainless Steel or NWN-Armour material is available.

8. Access Door
> Facilitate easy access for tower inspection and maintenance.

9. Maintenance Platform
> Features a double layer maintenance platform for internal cooling tower maintenance, making it safer and convenient, especially for fan servicing.

10. Cage Ladder & Handrail
CTI Certificated Cross Flow Open Type Cooling Tower FRP
 
Product Parameters

CTI Certificated Cross Flow Open Type Cooling Tower FRP

Tower Model Outline dimensions (mm) Weight (Kg)
NST W L H Dry Wet
NST-18-A15-2A11-C1 3310 1800 3500 1030  2480 
NST-20-B15-2A12-C1 3310 2000 3700 1110  2730 
NST-26-D18-3A14-C1 4080 2600 4110 1660  4130 
NST-30-D21-3A16-C1 4220 3000 4540 1890  4860 
NST-33-E24-3A17-C1 4540 3300 4790 2080  5520 
NST-35-F26-4A17-C1 5350 3500 4890 2960  8290 
NST-40-F30-4B17-C1 5750 4000 4940 3310  9690 
NST-43-G32-4B18-C1 5950 4300 5140 3550  10620 
NST-46-H34-4B20-C1 6150 4600 5560 3900  11740 
NST-48-H40-5B18-C1 7420 4800 5390 4560  13970 
NST-50-I42-5B20-C1 7560 5000 5610 5190  15280 
NST-54-J42-5B22-C1 7560 5400 6010 5650  16690 
NST-60-J47-5B22-C1 8040 6000 6210 6330  19120 


Other Upgraded Type NST series FRP Cooling Tower Solutions To Meet Different Working Conditions
 
CTI Certificated Cross Flow Open Type Cooling Tower FRP
CTI Certificated Cross Flow Open Type Cooling Tower FRP
CTI Certificated Cross Flow Open Type Cooling Tower FRP




OPTIONS
 
Permanent Magnetic Direct-Driven Fan System
Energy Saving Design

> Variable frequency control enables low-speed operation, high efficiency and high power factor.
> Direct-driven fan with no transmission losses and maintenance free.
> Energy efficiency rating up to IE5, with significant power saving and energy saving effects.
CTI Certificated Cross Flow Open Type Cooling Tower FRP

CTI Certificated Cross Flow Open Type Cooling Tower FRP
NWN-Armour Corrosion Resistant Technology
Corrosion Resistant Design

Galvanized steel panel covered with continuously upgraded NWN-Armour anti-corrosion coating. Corrosion resistant is closed to Stainless Steel, making it cost-effective alternative to Stainless Steel material.


Additional Accessories
PLC Control System/ Side Stream Filtration System/ Side Stream Filtration System/ Davit Arm/ Noise Level Reduction
 
NEWIN Manufacturing Base

CTI Certificated Cross Flow Open Type Cooling Tower FRP
NEWIN FACTORY 
Manufacturing base Situated In Huizhou, Guangdong. It Covers An Area Of 10,000 Square Meters.

ISO CERTIFICATION
ISO9001:2015 Quality Manergement System Certification ISO14001:2015 Environmental Manergement System Certification

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

CTI Certificated Cross Flow Open Type Cooling Tower FRP
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Closed Type Cooling Tower Series
· NSH/ NST Open Type Cooling Tower Series
· NTG Industrial Type Cooing Tower Series
· NECN/NECH Evaporative condenser
· NWFL Dry Air Cooler

CTI Certificated Cross Flow Open Type Cooling Tower FRP
NEWIN manufactures and stocks all major cooling tower accessories to meet maintenance and replacement needs of almost any size and types of cooling tower. Please contact us to customize the cooling tower accessories you need. 

CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange(PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
 
Packaging & Shipping

Open type cooling towers shipment

CTI Certificated Cross Flow Open Type Cooling Tower FRP
Closed type cooling towers shipment
CTI Certificated Cross Flow Open Type Cooling Tower FRP
CTI Certificated Cross Flow Open Type Cooling Tower FRP
Technical Strength& Standards

CTI Certificated Cross Flow Open Type Cooling Tower FRP
CTI Certificated Cross Flow Open Type Cooling Tower FRP

Certifications

CTI Certificated Cross Flow Open Type Cooling Tower FRPCTI Certificated Cross Flow Open Type Cooling Tower FRPCTI Certificated Cross Flow Open Type Cooling Tower FRPCTI Certificated Cross Flow Open Type Cooling Tower FRP

CTI Certificated Cross Flow Open Type Cooling Tower FRP



 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier