NWFL-V The NWFL-V series showcases our V type dry air cooler, expertly engineered with a cutting-edge Free Cooling System. This marvel of efficient cooling is exceptionally well-suited to HVAC systems and a multitude of other facilities. Experience the transformative power of cooling without water consumption, setting a new standard compared to traditional evaporative cooling methods.
Features
· Revolutionary V-type design paired with a state-of-the-art Free Cooling System,
Ensuring unparalleled cooling efficiency without the need for water consumption.
· Incorporation of top-tier components, such as the sophisticated EC motor,
Guaranteeing peak system efficiency and significant energy savings.
· Substantial redundancy included,
Effectively preventing any potential thermal performance loss.
· Exemplary reliability and designed for effortless maintenance.
Working Principle

When NWFL-V adiabatic cooler is in operation:
The EC fan system seamlessly draws in the refreshingly cool, dry air, guiding it into the tower with effortless precision through the ingeniously crafted V-shaped finned tube heat exchanger. This innovative V-shaped design maximizes the contact area, rapidly enhancing the cooling dynamics for both air and hot process fluids. The result is a remarkable boost in heat exchange efficiency. As these fluids undergo an intensive partition wall heat exchange with the cool, dry air, the previously hot, saturated air is efficiently expelled from the tower. This process achieves exceptional Free Cooling-or non-evaporative cooling-delivering consistent, high-performance results.
Series |
Type |
Capacity |
1. Fan Drive System |
2. Heat Exchange System |
NWFL-V |
V |
Range |
EC axial fans |
Finned coil |
Maximum thermal performance |
207~936kw |
Intelligent frequency conversion,
more energy saving |
Maximum heat transfer surface |
Free cooling
system |
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption. |
Application |
Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc. |
Parameter
Model |
Cooling Capacity |
Total Dimension |
Fan |
Weight |
L |
W |
H |
Nos of Fans |
Noise Level |
Power |
Shipping |
Operation |
kw |
mm |
mm |
mm |
Nos |
dB(A) |
kw |
kg |
kg |
NWFL-231-4D10-800V |
200 |
2740 |
2050 |
2190 |
4 |
79.4 |
3.14 |
1187 |
1386 |
NWFL-231-6D10-800V |
250 |
2740 |
2050 |
2190 |
4 |
82.7 |
3.76 |
1332 |
1586 |
NWFL-231-8D10-800V |
290 |
2740 |
2050 |
2190 |
4 |
87.8 |
4.89 |
1477 |
1786 |
NWFL-241-4D10-800V |
255 |
2740 |
2050 |
2550 |
4 |
80 |
4.43 |
1329 |
1590 |
NWFL-241-6D10-800V |
315 |
2740 |
2050 |
2550 |
4 |
81.8 |
5.47 |
1522 |
1854 |
NWFL-241-8D10-800V |
360 |
2740 |
2050 |
2550 |
4 |
84.5 |
6.49 |
1714 |
2119 |
NWFL-251-4D10-800V |
310 |
2740 |
2050 |
2980 |
4 |
81.5 |
6.44 |
1493 |
1817 |
NWFL-251-6D10-800V |
400 |
2740 |
2050 |
2980 |
4 |
83 |
7.61 |
1732 |
2146 |
NWFL-251-8D10-800V |
450 |
2740 |
2050 |
2980 |
4 |
85 |
8.81 |
1971 |
2475 |
NWFL-261-4D10-900V |
375 |
2740 |
2250 |
3300 |
4 |
80.8 |
7.37 |
1675 |
2060 |
NWFL-261-6D10-900V |
470 |
2740 |
2250 |
3300 |
4 |
84.9 |
8.35 |
1961 |
2453 |
NWFL-261-8D10-900V |
535 |
2740 |
2250 |
3300 |
4 |
86.4 |
9.75 |
2247 |
2847 |
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
· Heavy-duty Construction
Boasting a robust galvanized steel panel adorned with the cutting-edge NEWIN Armour anti-corrosion coating, this construction embodies exceptional resilience. Delivering corrosion resistance comparable to that of stainless steel, it facilitates operations with higher concentration cycles, significantly curtailing water consumption. This innovative coating is also designed for easy repair should any damage occur, ensuring lasting durability.
· V Type Finned Coil Heat Exchanger
Crafted for superior efficiency, the finned coil heat exchanger utilizes optimally spaced copper tubes and aluminum fins for unparalleled heat exchange performance. The copper tubes are meticulously secured to the coil headers through brazing and to the finned coil via flaring, providing unrivaled continuity in thermal conduction.
· EC Axial Fan
- Our EC motor's straight-shaft drive is engineered to withstand the test of time, featuring an impressive IP55 protection grade and F insulation grade. This ensures unwavering performance, even amidst challenging hot and humid conditions. It operates with remarkable smoothness and energy efficiency, meeting or exceeding IE4 standards.
- Featuring robust tapered roller bearings, our fans promise outstanding load-bearing capacity and longevity, with a service life surpassing 20,000 hours. This ensures seamless high performance and durability.
- With meticulous static and dynamic testing, noise is kept to a minimum while sustaining superior heat exchange efficiency. Thanks to advanced PFC technology, harmonics remain under 35%, guaranteeing that the EC fan system upholds high static efficiency, even at reduced speeds.
· Adiabatic Intelligent Controls
- EC fans feature intelligent frequency conversion, adeptly adapting to various working conditions on site, leading to substantial energy savings.
- A forced unit operation in dry mode is available for scenarios where water use is restricted, ensuring continuous operation.
· Options
- Enhance coil resistance capabilities
- Safeguard against coil freeze-up
- Opt for a low noise upgrade
- Boost redundancy levels for added reliability
NEWIN Manufacturing Base

NEWIN FACTORY
Nestled in the vibrant heart of Huizhou, Guangdong, our sprawling manufacturing base is a testament to advanced engineering, occupying an impressive 10,000 square meters. This state-of-the-art facility serves as a beacon of innovation and excellence in production.
ISO CERTIFICATION
With a suite of prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin stands as a paragon of commitment to unparalleled quality and eco-conscious practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Our cutting-edge Closed Type Cooling Tower Series is meticulously engineered to ensure optimal performance, meeting the highest standards of efficiency.
·
NSH/ NST Our highly efficient Open Type Cooling Tower Series is crafted for diversified applications, providing unmatched versatility and reliability.
·
NTG The robust Industrial Type Cooling Tower Series is designed to excel in demanding environments, offering unparalleled durability and performance.
·
NECN/NECH Experience our sophisticated Evaporative Condenser systems that deliver superior cooling efficiency, redefining performance standards.
·
NWFL Our innovative Dry Air Cooler solutions offer high-capacity and energy-efficient performance, perfectly suited for modern industrial needs.
NEWIN offers a comprehensive range of premium cooling tower accessories, expertly catering to maintenance and replacement needs across a variety of cooling tower sizes and types. Connect with us to customize the perfect cooling tower accessories tailored to your specific requirements.
CONTAIN:
· Fan drive system components, including fan, fan stack, reducer, motor, and shaft, are expertly crafted to enhance the overall functionality and performance of your systems.
· Water distribution elements, such as nozzles and drift eliminators, are meticulously designed for optimal fluid management and precision.
· Heat exchange components, including PVC infills and cooling coils, ensure efficient thermal transfer, maximizing energy efficiency and output.
· Additional accessories, including air inlet louvers and valves, are meticulously engineered for seamless integration, ensuring cohesive system operation.
Packaging & Shipping
Open Type Cooling Towers Shipment: Experience the pinnacle of logistics excellence with our expertly orchestrated shipping solutions, ensuring your equipment reaches its destination on time and in impeccable condition, ready to perform at its best.
Closed Type Cooling Towers Shipment: Enjoy peace of mind with our secure and efficient delivery services. Our meticulous handling process is designed to safeguard your valuable assets, ensuring they arrive in flawless condition, ready to meet your high standards and performance expectations.
Technical Strength& Standards