Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact

Product Details
Customization: Available
Cooling Method: Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, CE, SGS
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
  • Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
  • Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
  • Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
  • Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
  • Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NAL Series
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ordinary
Material
PVC
Application Fields
Cross Flow Cooling Tower
Model--Lah
PVC
Size
65/70thicknessx Any Length X Any Width
Continuous Operation Tempperature
50 Degree Centigrade
Max.Applicationtemp. (Short Term)
60 Degree Centigrade
Color
Black
Corrugation Height
18 mm
Thickness
65/70mm
Application
Cross Flow Square Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Specification
65/70mm thickness
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

Introducing our PVC Material Cooling Tower Fill Nal Air Inlet Louver, a pivotal innovation designed to enhance your system's efficiency and performance.

Discover the remarkable capabilities of the NAL series, engineered to set new standards in air management. Explore the Newin NAL series air inlet louver, a product crafted for superior functionality and reliability. iConstructed with precision, our louvers are made from high-strength PVC sheets, skillfully bonded for maximum durability. Choose from a surrounding frame of galvanized or stainless steel. The sophisticated honeycomb inlet grille design significantly enhances airflow into your cooling tower, efficiently filters out impurities, and prevents unwanted water splash. This advanced feature helps avoid icing, mitigates water damage, and reduces unnecessary water loss, ensuring optimal performance and longevity.

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact

Features

Features

· Effectively shields the interior by preventing any debris from entering, ensuring long-term efficiency and cleanliness.
· Ingeniously designed to prevent the splash of water droplets, maintaining optimal performance and reducing maintenance needs.
· Expertly restricts the amount of sunlight entering the cooling tower, significantly impeding algae growth for a cleaner system.
· Effectively diminishes noise emanating from the tower, providing a calmer, more serene environment.
· Achieves an impressively low pressure drop, maximizing efficiency and lowering energy costs.
· Designed for easy installation, with convenient access for swift cleaning and maintenance, minimizing downtime.
· Versatile usage in a broad spectrum of new and retrofit applications, including air inlets for both package and field-erected counter flow.
and straight-sided cross flow towers, fresh air make-up systems, and air pollution control scrubbers, offering flexible integration options.


Parameter

Properties
Tailor your air management system with our NAL air inlet louver! Whether you need specific dimensions like length and width, or have preferences for materials and thickness, simply communicate your detailed requirements to us. Newin is committed to meeting all customer needs. Plus, we offer fill media in flame retardant or anti-bacterial designs on request.

Module Length (Max)  mm 2440
Module Width (Max)  mm 600
Module Thickness  mm 65
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing
Newin provides comprehensive structure and installation guidance, including storage advice and a quality control report with each shipment. This ensures customers are well-prepared upon receiving materials. We also offer OEM services and can create special mold designs upon request.Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact

Application

Application & Usage

The Newin EVL air inlet louver is expertly designed for integration with counter flow cooling towers. Certified by rigorous SGS testing and aligned with ASTM standards, it ensures superior infill quality, thereby enhancing the cooling tower's efficiency. Simply provide us with your tower model or dimensions, and we will accurately determine the appropriate air inlet louver size to optimize your cooling tower's performance.
Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact


Applicable Commercial Standards
The materials for the sheets are meticulously tested following SGS guidelines and ASTM standards. We offer comprehensive testing of individual or all properties upon request, ensuring that your products meet the highest quality specifications.

Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Air Inlet Louver Replacement
To ensure exceptional quality and reliability for your maintenance or repair projects, fill in the measurements data below. Trust in Newin for a seamless site visit or maintenance service, engineered to integrate flawlessly with your cooling tower's fills or components. Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact

NEWIN Manufacturing Base

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.

ISO CERTIFICATION
With immense pride, we underscore our unwavering commitment to unparalleled quality and environmental stewardship through our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification. These certifications set the benchmark for industry excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model showcases the pinnacle of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance. Set to industry standards, it consistently exceeds expectations for enduring excellence.
· NTG Explore the extraordinary capabilities of our Industrial Type Cooling Tower Series, specifically crafted for heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new performance standards and revolutionizing operational excellence in the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Experience unmatched security and accuracy through our meticulously managed transportation service, crafted specifically for open-type cooling towers. Each tower is expertly wrapped with top-tier materials and pioneering packing techniques to ensure they arrive at your location in impeccable condition. Our steadfast commitment to protecting your investment offers complete security from any transit risks, allowing you to relish the convenience of our seamless logistics and on-time delivery. This precision service is thoughtfully designed to enable the prompt activation of your cooling solutions, removing any delays.

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
Closed type cooling towers shipment: Delight in the confidence of our superior packaging solutions, meticulously designed for closed-type cooling towers. Each unit is carefully safeguarded with unparalleled care and robust materials to endure demanding transit conditions, ensuring their flawless arrival and immediate operational readiness. Our unwavering dedication to excellence and prompt delivery empowers you to seamlessly incorporate our cutting-edge cooling technologies into your operations with ease, liberating you from logistical concerns.
Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
Technical Strength& Standards

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact
Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact

Certifications

Reliable Air Inlet Louver for Enhanced Wet and Dry Air ContactReliable Air Inlet Louver for Enhanced Wet and Dry Air ContactReliable Air Inlet Louver for Enhanced Wet and Dry Air ContactReliable Air Inlet Louver for Enhanced Wet and Dry Air Contact

Reliable Air Inlet Louver for Enhanced Wet and Dry Air Contact














Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More