EVL Cooling Tower Air Inlet Louver
Discover the pinnacle of engineering with the Newin EVL Series Air Inlet Louver, crafted from robust high-strength PVC sheets and seamlessly bonded for unmatched durability. Complementing this is a premium frame, available in your choice of galvanized steel or stainless steel, designed to withstand the harshest conditions. At the heart of its innovation is the advanced honeycomb inlet grille, meticulously engineered to enhance airflow into the cooling tower. This cutting-edge design not only optimizes ventilation but also acts as a highly effective filter, meticulously sifting out impurities and preventing unwanted water splashes. These features are pivotal in averting potential icing and water damage, while simultaneously ensuring the conservation of water resources, thus marking a superior choice for sustainability and efficiency.
Features
Features
- Enhance and optimize air flow seamlessly into the cooling tower, ensuring superior performance.
- Efficiently prevent unwanted debris from entering, maintaining pristine operational conditions.
- Skillfully prevent the splash and loss of precious water droplets, conserving resources.
- Strategically restrict sunlight infiltration to inhibit algae proliferation, promoting longevity.
- Expertly reduce operational noise, fostering a quieter environment around the tower.
- Designed for achieving remarkably low pressure drop, optimizing energy efficiency.
- Engineered for straightforward installation and hassle-free access for cleaning and maintenance, ensuring user convenience.
- Versatile in application, suitable for an expansive range of new projects, as well as retrofit solutions. Perfect for enhancing air inlets for both package
and field-erected counter flow and straight-sided cross flow towers. Also ideal for fresh air make-up systems, air pollution control scrubbers, and VOC strippers, providing comprehensive adaptability.
Parameter
Properties
With diverse specifications available for the EVL air inlet louver, such as varying lengths, widths, materials, and thicknesses, please communicate your specific requirements to us. This ensures we provide a precise solution and competitive offer. Newin is equipped to fulfill all customer needs, with options for fill media in flame retardant or anti-bacterial varieties available upon request.
Module Length (Max) |
mm |
2440 |
Module Width (Max) |
mm |
800 |
Module Thickness |
mm |
80 |
Flute Height |
mm |
25 |
Sheet Thickness - Before Forming |
mm |
0.5 |
Sheet Thickness - After Forming |
mm |
0.4 |
Max. application temp. (short time) - PVC |
°C |
60 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Drawing
Newin provides comprehensive structure and installation drawings, along with expert job site storage guidance and a thorough quality control report accompanying each shipment. This ensures customer satisfaction upon receiving the materials. We also offer OEM services and special mold designs tailored to your requests.

Application
Application & Usage
The Newin EVL Air Inlet Louver is expertly designed for counter flow cooling towers. With rigorous SGS testing in accordance with ASTM Standards, this ensures a premium quality infill to maximize your cooling tower's efficiency. Share your tower model or dimensions with us, and we will precisely determine the optimal air inlet louver size tailored for your cooling tower replacement needs.
Applicable Commercial Standards
Our sheet materials undergo stringent SGS testing in alignment with ASTM standards. We offer comprehensive testing for each property of your products upon request, ensuring adherence to the highest quality standards.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Field Data for Cross Flow Film Fill Replacement
Enter the measurements below for your maintenance cooling tower or repair projects that demand superior quality and dependability. Trust Newin for site visits or maintenance services engineered to precisely fit the cooling tower fills or components. Our expertise ensures a seamless integration and long-lasting performance.

NEWIN Manufacturing Base

NEWIN FACTORY
Our state-of-the-art manufacturing base, nestled in the vibrant and industrious region of Huizhou, Guangdong, proudly extends over an impressive 10,000 square meters. This expansive facility serves as a robust foundation for pioneering innovation and achieving outstanding excellence in our field.
ISO CERTIFICATION
Proudly adhering to the industry's highest standards, our prestigious certifications include ISO9001:2015 for exceptional Quality Management and ISO14001:2015 for our unwavering commitment to leading Environmental Management practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Explore our state-of-the-art Closed Type Cooling Tower Series, expertly engineered to deliver precision, maximum efficiency, and superior performance.
·
NSH/ NST Introducing our meticulously designed Open Type Cooling Tower Series, crafted to ensure optimal performance and unwavering reliability every time.
·
NTG Discover our Industrial Type Cooling Tower Series, skillfully crafted to meet the rigorous and demanding needs of industrial applications.
·
NECN/NECH Our exceptional Evaporative Condenser guarantees superior cooling efficiency and outstanding performance, setting new benchmarks in the industry.
·
NWFL Our Dry Air Cooler series stands as a beacon of cutting-edge design and unparalleled energy efficiency, setting new standards in cooling technology.
NEWIN is your trusted partner in providing a comprehensive range of cooling tower accessories. We not only stock but also manufacture components to support maintenance and replacements for virtually any size or type. Reach out to us to tailor the perfect accessories that precisely meet your specific requirements.
CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange (PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: Embark on an unparalleled journey of delivery excellence with our open type cooling towers. These state-of-the-art towers, crafted meticulously to adhere to the highest safety and reliability standards, promise an unprecedented logistical experience. Our expert team masterfully handles every detail, ensuring your order arrives timely and seamlessly at your specified location. Experience delivery perfection that not only meets but elevates expectations.
Closed Type Cooling Towers Shipment: Our closed type cooling towers are handled with meticulous care and precision throughout the shipping process, guaranteeing they arrive at your location in impeccable condition. We pledge a secure and timely delivery, preserving the exceptional performance and structural integrity of our top-tier cooling systems. With our seasoned expertise, you are assured of a smooth and worry-free shipping experience, instilling confidence in each step of the journey from our factory to your doorstep.
Technical Strength& Standards

Certifications