PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
  • PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
  • PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
  • PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
  • PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
  • PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
LAD
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Material
PVC
Application Fields
Counter Flow
Transport Package
Pallet/ 20gp/40gp Container
Specification
Height: 50 mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

Introducing the LAD PVC Material Drift Eliminator - a cutting-edge solution meticulously crafted for premier, high-performance cooling towers from renowned brands. Designed to seamlessly integrate with these advanced systems, our drift eliminator ensures optimal efficiency and superior performance, elevating cooling tower functionality to new heights.

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

Product Description

LAD Introducing LAD series cellular drift eliminator by Newin (Guangdong) Machinery Co., Ltd. is expertly designed to significantly improve air quality in cooling systems by effectively removing small water droplets from the exhaust air. These droplets, if not captured, can cause unwanted nuisances and potential health risks. Our state-of-the-art LAD drift eliminators are engineered to create a complex path for airflow, compelling water droplets to change course and collide with the side walls. This process effectively coalesces the droplets, allowing them to drain back into the tower's wet section, thus ensuring optimal performance.




FEATURES

- Remarkable anti-aging properties and superior water absorption capacity enhance durability.
- Engineered for minimal airflow resistance while maintaining exceptional strength for reliable performance.
- Effortless installation coupled with an extended service life ensures that Newin's drift eliminators offer unbeatable value and efficiency.
Parameter

PROPERTIES

When it comes to the diverse needs for LAD drift eliminators-whether it be length, width, materials, or thickness-rest assured that Newin covers all specifications with precision. Share your detailed requirements with us to receive tailored solutions and competitive offers. We also provide fill media options in flame-retardant or anti-bacterial finishes upon request, ensuring that every demand is met with versatility and quality.
Module Length (Max)  mm 1000
Module Width  (Max)  mm 500
Module Height  mm 50
Flute Height  mm 20
Sheet Thickness - Before Forming  mm 0.4
Sheet Thickness - After  Forming  mm 0.3
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


STRUCTURE & INSTALLATION DRAWING

Newin provides comprehensive structure and installation drawing services, complete with jobsite storage recommendations and a quality control report to ensure peace of mind upon material delivery. When you receive your materials, you'll be informed and prepared with our guidance. Additionally, OEM or customized mold design services are readily available to accommodate special requests, making us your trusted partner in innovation and adaptability.
PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
Application

APPLICATION & USAGE

Newin LAD cellular drift eliminator designed for cooling towers, it boasts SGS certification according to ASTM standards, ensuring superior infill quality that maximizes cooling tower efficiency. Share your tower model or dimensions with us, and we'll expertly calculate the number of sheets necessary for your replacement needs.

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems



APPLICABLE COMMERCIAL STANDARDS

Our sheets are manufactured in strict adherence to SGS tests and ASTM standards. Specific properties tested on your products can also be accommodated upon request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.



FIELD DATA FOR CELLULAR DRIFT ELIMINATOR REPLACEMENT

Provide the measurement data below for your maintenance or repair projects. When quality and reliability matter, trust Newin for site visits and maintenance services, expertly crafted to fit your cooling tower fills and components.

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

Options

Introducing the Newin cooling tower drift eliminator, meticulously designed for optimal efficiency. This state-of-the-art product promises to significantly enhance your cooling system's natural ventilation capabilities by effectively minimizing drift loss. Trust Newin (Guangdong) Machinery Co., Ltd. to deliver innovation and excellence with every solution.
PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

NEWIN Manufacturing Base

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements. At the heart of this vibrant ecosystem, NEWIN's manufacturing prowess shines, embodying cutting-edge technology and unmatched expertise, fostering a culture of relentless innovation.

ISO CERTIFICATION
Our unwavering commitment to unparalleled quality and environmental stewardship is proudly underscored by our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification. These accolades reflect our dedication to maintaining superior standards in all aspects of our operations as we lead by example in sustainable practices.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. These towers are engineered with precision, ensuring they stand as paragons of efficiency in the cooling industry.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards. These towers are a testament to our engineering acumen, offering reliability that industry leaders trust.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power. These towers are built for the toughest environments, delivering power and dependability.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence. These condensers epitomize sophisticated cooling solutions that elevate operational efficiency.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling. These coolers redefine airflow dynamics, ensuring unparalleled efficiency and performance.

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower. Our solutions are crafted to enhance the longevity and efficiency of your systems.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision. This system is designed to deliver exceptional performance consistently.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance. These components ensure effective and even water distribution throughout.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency. These options maximize heat transfer efficiency, reducing energy consumption.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency. These accessories are integral for optimizing the operational capabilities of your cooling tower systems.
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience excellence with our open-type cooling towers, as they embark on their journey to you. We infuse meticulous care into every aspect of packaging, using only premium materials and innovative packing strategies to safeguard these advanced units. This dedication ensures they arrive in pristine condition, protected from transit harm. With our seamless logistics and reliable delivery, your cooling tower is set to power up promptly, bringing our engineering prowess to life right from the start.

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
Closed Type Cooling Towers Shipment: Revel in unmatched assurance with our custom-crafted packaging for closed-type cooling towers. Each unit is securely encased, primed to weather any transport challenges and land at your doorstep immaculate and performance-ready. Our steadfast dedication to superior quality and precise shipping means you can devote your attention to reaping the full rewards of our state-of-the-art cooling solutions, free from worry or inconvenience.
PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
Technical Strength& Standards

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems
PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

Certifications

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling SystemsPP Drift Eliminator for Enhanced Natural Ventilation in Cooling SystemsPP Drift Eliminator for Enhanced Natural Ventilation in Cooling SystemsPP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

PP Drift Eliminator for Enhanced Natural Ventilation in Cooling Systems

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More