MAN Series Counter flow cooling tower infill/fills
MAN Series Counter FlowFilm Fill is hanging or bottom supported configuration type, crossed corrugations provide the surface area and turbulence to develop efficient heat transfer.UV inhibited, chemically resistant polyvinyl chloride (PVC). Good hydrophilicity, small ventilation resistance. 915/1220mm width is available to satisfy different cooling towers request. Applicable to any counter flow cooling tower worldwide.
Features
Features
· Advanced technology, reasonable design, with good cooling effect.
· Good ventilation, small resistance, strong hydrophilic, large contact area, and good film-forming, easy packing, good heat conductivity, good chemical stability, acid, alkali and organic solvent corrosion, etc.
· The staggered ring material form assembling, packing general is 60 ° Angle, polyvinyl chloride (PVC), polypropylene (PP) two kinds of packing material available.
Picture in detail

Parameter
Properties
With different request in MAN film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max.) |
mm |
3660 |
Module Width |
mm |
915 / 1220 |
Module Depth |
mm |
- |
Flute Height |
mm |
19 |
Flute Corrugation Angle |
degrees |
- |
Surface Area |
m2/m3 |
150 |
Sheet Thickness - Before Forming |
mm |
0.38 |
Sheet Thickness - After Forming |
mm |
0.35 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - High temp. |
°C |
80 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Drawing
Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.
Application
Application & Usage
Newin MAN Film Fill is applicable for other brands counter flow cooling tower series, like MD, CP, MC Series etc. worldwide, with SGS test to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.
Applicable Commercial Standards
Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Filed Data for Counter Flow Film Fill Replacement
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components.
Options
You May Also Find These Interesting:

NEWIN Manufacturing Base

NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.
ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.
WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
·
NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
·
NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
·
NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
·
NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.
CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping
Open type cooling towers shipment: Experience the ultimate in secure transportation with our expertly crafted open-type cooling towers. Each tower is meticulously packaged using top-tier materials and advanced packing strategies to guarantee they arrive in impeccable condition. Our commitment to safety and security ensures protection against any potential transit damages. Benefit from our seamless logistics and timely delivery, designed to have your cooling solutions up and running with zero delay.
Closed type cooling towers shipment: Indulge in the confidence provided by our superior packaging solutions for closed-type cooling towers. Each unit is carefully and robustly encased to endure transportation challenges, ensuring they arrive unscathed and ready for action. Our steadfast commitment to quality control and prompt shipping allows you to focus on harnessing our cutting-edge cooling technology for your specific needs, without worrying about logistics.
Technical Strength& Standards


Certifications



