PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
  • PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
  • PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
  • PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
  • PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
  • PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MAN
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Round
Noise Level
Ordinary
Application Fields
Industrial
Material
PVC or PP or UPVC
Cooling Tower Type
Counter Flow Cooling Tower
Width
915/1220mm
Lenghth (mm)
1220, 1830, 2440, Any Length
Colour
Customizable
Max. Operation Temp.
80 °c (Short Time)
Max. Appllication Temp.
60 °c (Short Time)
Transport Package
20/40/40hq Container with Loose Packing
Specification
915/1220 x any length
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

MAN Series Counter Flow Cooling Tower Infill/Fills – the future of cooling technology.

MAN Series Counter Flow Film Fill – a revolution in efficient cooling solutions. This innovative fill is designed with a hanging or bottom-supported configuration. Its crossed corrugations ingeniously provide ample surface area and create turbulence, optimizing heat transfer efficiency. Constructed from UV-inhibited, chemically resistant polyvinyl chloride (PVC), it ensures longevity and durability. The fill boasts excellent hydrophilicity and minimal ventilation resistance, making it a superior choice. Available in 915mm and 1220mm widths, it is crafted to meet the diverse needs of cooling towers globally. Suitable for any counter flow cooling tower worldwide, it sets a new standard in cooling performance.

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Features

Exceptional Features of Our Product

· State-of-the-art technology and an ingenious design converge to deliver a remarkable cooling effect.
· Optimized for superior ventilation with minimal resistance, this product boasts excellent hydrophilic properties and a vast contact area. It forms a strong film effortlessly, ensuring easy packing, exceptional heat conductivity, and remarkable chemical stability. It is resilient to acid, alkali, and organic solvent corrosion.
· The innovative staggered ring material design allows for flexible assembly, typically at a 60° angle. Choose between high-quality polyvinyl chloride (PVC) and polypropylene (PP) packing materials to suit your needs.



Explore the Picture in Detail

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Parameter

Properties

At Newin (Guangdong) Machinery Co., Ltd., we understand the unique and varied requirements of our clients when it comes to the MAN film fill. Whether it's specific dimensions such as length and width, bespoke materials, or precise thickness specifications, we invite you to share your detailed needs with us. This ensures we provide you with the most accurate solutions and competitive offers. We pride ourselves on our capability to meet all customer demands and offer fill media in flame retardant or anti-bacterial versions, available upon request.
Module Length (Max.)  mm 3660
Module Width   mm 915 / 1220
Module Depth   mm -
Flute Height  mm 19
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.38
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing

At Newin, we are committed to ensuring seamless installation and optimal performance of your systems. We provide comprehensive structure and installation drawings, coupled with valuable jobsite storage advice. Along with your shipment, you'll receive a meticulous quality control report, ensuring you have everything you need to succeed from the moment the materials arrive. For those with unique needs, custom OEM designs or specialized mold designs are also available upon request.PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Application

Application & Usage

The versatile Newin MAN Film Fill is ingeniously designed to fit seamlessly into various counter flow cooling tower series from other renowned brands, such as MD, CP, MC Series etc. across the globe. Backed by rigorous SGS testing, our top-tier infill ensures your cooling tower operates at peak efficiency. Share your tower model or dimensions with us, and we'll expertly assess the number of sheets required for your cooling tower upgrade.
PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features

Applicable Commercial Standards

Our sheets are manufactured adhering to stringent SGS test protocols in alignment with ASTM standards. Should you require, individual or comprehensive property tests as outlined below can be conducted upon request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Counter Flow Film Fill Replacement

Provide the measurements below for your maintenance or repair projects. Newin assures unparalleled quality and dependability. Trust in our expertise for site visits or maintenance services, engineered specifically to fit your cooling tower fills or components.
PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Options

You May Also Find These Intriguing:

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
NEWIN Manufacturing Base

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Discover the pinnacle of secure transportation with Newin (Guangdong) Machinery Co., Ltd.'s expertly crafted open-type cooling towers. Our packaging process is a testament to precision and excellence, employing only the finest materials and sophisticated packing techniques to ensure each tower arrives in pristine condition. Our dedication to safety and security shields your investment from any transit-related perils. Experience the ease of our streamlined logistics and punctual delivery service, guaranteeing your cooling solutions are operational without a hitch.

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Closed type cooling towers shipment: Revel in the assurance that comes with Newin's unrivaled packaging solutions for closed-type cooling towers. Each unit is encased in meticulously engineered protective layers, designed to withstand any transportation challenges. Our unwavering commitment to quality assurance and speedy dispatch means you can concentrate on leveraging our state-of-the-art cooling technology for your unique requirements, with complete peace of mind about logistics and shipment integrity.
PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
Technical Strength& Standards

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features
PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features

Certifications

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation FeaturesPVC Fill for Cooling Tower with Enhanced Mixing Ventilation FeaturesPVC Fill for Cooling Tower with Enhanced Mixing Ventilation FeaturesPVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features

PVC Fill for Cooling Tower with Enhanced Mixing Ventilation Features





Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More