Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems

Product Details
Customization: Available
Ventilation Mode: Mechanical Ventilation
Material: Metal

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
  • Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
  • Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
  • Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
  • Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
  • Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Find Similar Products
  • Overview
  • Features
  • Working Principle
  • Parameter
  • Components& Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWFL-V
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
207~936kw
Transport Package
20/40/40hq Container
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000

Product Description

Introducing the High-Capacity Dry Air Cooler, an epitome of innovation in cooling solutions.


Model NWFL-V This NWFL-V series, distinguished by its V type dry air cooler configuration, is crafted to perfection with an integrated Free Cooling System. It provides unparalleled cooling efficiency, making it an ideal choice for HVAC systems and a variety of advanced facilities. Additionally, it champions sustainability by eliminating water consumption, setting it apart from conventional evaporative cooling methods.

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Features
· Ingenious V-type design paired with an advanced Free Cooling System,
Ensures exceptional cooling efficiency while completely eliminating water consumption.

· Incorporation of optimally efficient components, including state-of-the-art EC motors,
Guaranteeing unparalleled system efficiency and remarkable energy savings.

· Significant redundancy available,
Effectively eliminating any risk of thermal performance degradation.

· Unmatched reliability coupled with effortless maintenance.
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
 
Working Principle

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
When NWFL-V adiabatic cooler is in operation:
Experience the pinnacle of cooling efficiency with our EC fan system, expertly designed to draw in crisp, refreshing air. As this invigorating air flows into the tower, it seamlessly integrates with the V-shaped finned tube heat exchanger. This innovative V-shaped design boasts an expansive contact surface, accelerating the cooling dynamics of both the incoming air and the heated process fluid. This harmonized interaction significantly elevates heat exchange efficiency, setting new standards in cooling performance. Following an optimized partition wall heat exchange with the dry, cool air, the previously hot and saturated air is effectively expelled from the tower. This process ensures the realization of superior Free Cooling (non-evaporative cooling), maximizing energy efficiency and operational excellence.

Series Type Capacity 1. Fan Drive System 2. Heat Exchange System
NWFL-V V Range EC axial fans Finned coil
Maximum thermal performance 207~936kw Intelligent frequency conversion, 
more energy saving
Maximum heat transfer surface
Free cooling 
system
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption.
Application Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc.
Parameter
 
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Model Cooling Capacity Total Dimension Fan Weight
L W H Nos of Fans Noise Level Power Shipping Operation
kw mm mm mm Nos dB(A) kw kg kg
NWFL-231-4D10-800V 200 2740 2050 2190 4 79.4 3.14  1187  1386 
NWFL-231-6D10-800V 250 2740 2050 2190 4 82.7 3.76  1332  1586 
NWFL-231-8D10-800V 290 2740 2050 2190 4 87.8 4.89  1477  1786 
NWFL-241-4D10-800V 255 2740 2050 2550 4 80 4.43  1329  1590 
NWFL-241-6D10-800V 315 2740 2050 2550 4 81.8 5.47  1522  1854 
NWFL-241-8D10-800V 360 2740 2050 2550 4 84.5 6.49  1714  2119 
NWFL-251-4D10-800V 310 2740 2050 2980 4 81.5 6.44  1493  1817 
NWFL-251-6D10-800V 400 2740 2050 2980 4 83 7.61  1732  2146 
NWFL-251-8D10-800V 450 2740 2050 2980 4 85 8.81  1971  2475 
NWFL-261-4D10-900V 375 2740 2250 3300 4 80.8 7.37  1675  2060 
NWFL-261-6D10-900V 470 2740 2250 3300 4 84.9 8.35  1961  2453 
NWFL-261-8D10-900V 535 2740 2250 3300 4 86.4 9.75  2247  2847 
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
· Heavy-duty Construction

Our specially designed galvanized steel panel, featuring the innovative NEWIN Armour anti-corrosion coating, ensures remarkable durability and resistance to corrosion that rivals even stainless steel. This cutting-edge coating allows the equipment to operate efficiently with higher concentration cycles, resulting in significantly reduced water consumption. In the event of damage, the coating can be easily and swiftly repaired, ensuring longevity and reliability.
 
· V Type Finned Coil Heat Exchanger

Engineered for optimal heat exchange, the finned coil heat exchanger is constructed using premium copper tubes and expertly spaced aluminum fins. The copper tubes are securely affixed to the coil headers by brazing and to the finned coil by flaring, guaranteeing maximum thermal conduction and outstanding performance.
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
 
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
· EC Axial Fan

- Our EC motors, featuring a straight-shaft drive, are engineered to an impressive IP55 protection grade and F insulation grade, ideal for continuous operation in challenging hot and humid conditions. These fans operate seamlessly, providing exceptional energy efficiency that meets or exceeds IE4 standards.

- Equipped with robust tapered roller bearings, the fans demonstrate superior load-bearing capabilities and offer extensive service longevity, surpassing 20,000 hours of high-performance operation.

- Meticulously tested through both static and dynamic assessments, our fans minimize noise while maintaining top-tier heat exchange efficiency. PFC technology ensures harmonics remain under 35%, preserving high static efficiency across variable speeds.
 
· Adiabatic Intelligent Controls

- Our EC fans feature intelligent frequency conversion, adapting effortlessly to varying site conditions and significantly optimizing energy savings.

- In dry operation scenarios where water usage is restricted, the force unit ensures reliable and efficient performance.
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems

 

· Options

- Enhance the coil's durability for increased resilience.
- Implement safeguards against coil freeze-up for seamless operation in all conditions.
- Opt for a low noise upgrade to further reduce operational sound levels.
- Increase the redundancy level to ensure continuous operation and reliability under demanding conditions.
NEWIN Manufacturing Base

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
NEWIN FACTORY
Nestled in the vibrant city of Huizhou, Guangdong, our expansive manufacturing base spans an impressive 10,000 square meters. This state-of-the-art facility provides an environment conducive to fostering innovation and achieving production excellence.

ISO CERTIFICATION
Proudly holding prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin stands as a beacon of dedication to unparalleled quality and eco-friendly practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN State-of-the-art Closed Type Cooling Tower Series engineered for optimal performance in diverse applications.
· NSH/ NST Highly efficient Open Type Cooling Tower Series expertly crafted for a wide range of applications.
· NTG Durable Industrial Type Cooling Tower Series designed to excel in demanding environments.
· NECN/NECH Sophisticated Evaporative Condenser systems that promise superior cooling efficiency.
· NWFL Breakthrough Dry Air Cooler solutions offering high-capacity and energy-efficient performance.

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
NEWIN offers a comprehensive inventory of premium cooling tower accessories, crafted to meet maintenance and replacement needs across various cooling tower sizes and types. Connect with us to customize the precise cooling tower accessories you need.

CONTAIN:
· Fan drive system components including fan, fan stack, reducer, motor, and shaft, meticulously crafted to enhance functionality and reliability.
· Water distribution elements like nozzles and drift eliminators, precisely designed for optimal fluid management.
· Heat exchange components such as PVC infills and cooling coils, ensuring effective and efficient thermal transfer.
· Additional accessories including air inlet louvers and valves, thoughtfully engineered for seamless integration and superior performance.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience the pinnacle of logistical excellence with our seamlessly coordinated shipping solutions. Our expert team ensures that your equipment is delivered punctually and in perfect condition, reflecting our commitment to top-tier service and reliability.

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Closed Type Cooling Towers Shipment: Embrace peace of mind with our unparalleled secure and efficient delivery service. Our meticulous handling process is designed to protect and preserve your valuable assets every step of their journey, guaranteeing they arrive in flawless condition.
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Technical Strength& Standards

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems
Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems

Certifications

Efficient High-Capacity Air Cooler for Advanced Dry Cooling SystemsEfficient High-Capacity Air Cooler for Advanced Dry Cooling SystemsEfficient High-Capacity Air Cooler for Advanced Dry Cooling SystemsEfficient High-Capacity Air Cooler for Advanced Dry Cooling Systems

Efficient High-Capacity Air Cooler for Advanced Dry Cooling Systems

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now