Innovative Newin Dry Cooler for Multi-Cell Cooling Applications
NWFL-VA The NWFL-VA series represents the pinnacle of dry air cooling technology, ingeniously crafted in a V type design and integrated with a state-of-the-art Adiabatic Cooling System. Experience unparalleled efficiency in cooling performance all year round. This free cooling solution is perfect for data centers and various high-demand facilities, offering superior water conservation by drastically reducing usage compared to traditional evaporative cooling systems.
Features
· Ingenious V-type design along with an advanced adiabatic cooling system,
Delivering exceptional cooling efficiency while minimizing water usage.
· Includes optimally efficient components, such as the state-of-the-art EC motor,
Ensuring peak system efficiency and significant energy savings.
· Extensive redundancy options available,
Effectively eliminating any loss in thermal performance.
· Remarkable reliability paired with easy maintenance.
Working Principle

When the NWFL-VA adiabatic cooler operates:
The process begins as cold water gracefully cascades from the top of the cooler, evenly distributing itself across the high-efficiency evaporative cooling pads. Simultaneously, cool, dry air is expertly drawn in by the advanced EC axial fan, sweeping over the pads for an initial precooling phase. This adiabatic precooling of air significantly enhances its cooling capacity, making it even more effective at rapidly reducing temperatures of the warm process fluid. Such innovation ensures optimal performance and energy efficiency for all your multi-cell cooling applications.
Series |
Type |
Capacity |
1. Fan Drive System |
2. Heat Exchange System |
3. Adiabatic Pre-cooler |
NWFL-VA |
V |
Range |
EC axial fans |
Finned coil |
Evaporative cooling pads |
Maximum thermal performance |
300~1680kw |
Intelligent frequency conversion,
more energy saving |
Maximum heat transfer surface |
Precooling the ambient air temperature,
improving higer cooling efficency |
*4.The wake up is on the top of the pads can ensure the cool dry air in adiabatic precooling process when the pump is not running. |
*5. Recirculation system is designed for further reduce the total water consumption. |
Adiabatic cooling
system |
Exceeding 90% annual water saving compared to normal cooling tower |
Application |
Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc. |
Parameter
Model |
Configuration Mode |
Flow |
Cooling Capacity |
Dimension (mm) |
Nos of Fins |
Fan Diameter |
Power |
F/V |
m3/h |
kw |
L |
W |
T |
nos |
mm |
kw |
NWFL-300VA |
V |
52 |
300 |
4000 |
1290 |
198 |
2 |
EC900 |
7.6 |
NWFL-600VA |
V |
104 |
600 |
4000 |
1290 |
198 |
4 |
EC900 |
15.3 |
NWFL-520VA |
V |
90 |
520 |
4500 |
1786 |
198 |
2 |
EC800 |
12.6 |
NWFL-1040VA |
V |
180 |
1040 |
4500 |
1786 |
198 |
4 |
EC800 |
25.3 |
NWFL-600VA |
V |
105 |
600 |
4000 |
2280 |
198 |
2 |
EC900 |
15.3 |
NWFL-1200VA |
V |
210 |
1200 |
4000 |
2280 |
198 |
4 |
EC900 |
30.6 |
NWFL-840VA |
V |
144 |
840 |
5500 |
2777 |
198 |
2 |
EC900 |
19.1 |
NWFL-1680VA |
V |
288 |
1680 |
5500 |
2777 |
198 |
4 |
EC900 |
38.2 |
* This table sample is a snapshot of the data available at the time of issuance. For precise engineering or construction planning, always consult with our dedicated sales team and experienced engineers to verify and obtain comprehensive details before making a purchase.
* For multi-cell requirements, reach out to our expert team at NEWIN to explore tailored solutions. Please note, NEWIN retains the right to update or modify the parameters or dimensions mentioned in this table without prior notification.
Components& Options
· Heavy-Duty Construction
Our robust galvanized steel panel is fortified with the exclusive NWN-Armour anti-corrosion coating, offering exceptional resistance and durability akin to stainless steel. This advancement empowers the equipment to operate efficiently with higher concentration cycles, significantly reducing water consumption. Should damage occur, the coating is easily repairable.
· V Type Finned Coil Heat Exchanger
Engineered with precision, the finned coil heat exchanger features copper tubes and meticulously spaced aluminum fins, ensuring unmatched heat exchange performance. The copper tubes are expertly secured to the coil headers through brazing and to the finned coil via flaring, optimizing thermal conduction continuity.
· EC Axial Fan
- Featuring an EC motor straight-shaft drive, this fan boasts a motor protection grade of IP55 and insulation grade F, making it ideal for prolonged operation in hot and humid environments, delivering smooth performance. EC motors achieve exceptional energy efficiency, reaching IE4 or higher.
- The fan incorporates tapered roller bearings, renowned for their substantial load-bearing capacity and extended lifespan, with a rated service life exceeding 20,000 hours.
- Through rigorous static and dynamic testing during production, noise levels are minimized while ensuring optimal heat exchange performance. The PFC technology maintains harmonics below 35%, allowing the EC fan system to sustain high static efficiency, even at reduced speeds.
· Adiabatic Pre-cooler
- Our evaporative cooling pads, crafted from cellular materials of impregnated cellulose with varying flute patterns, are housed within a durable stainless steel framework. Water is distributed from the top, ensuring complete wetting for maximum efficiency.
- Enhanced with an anti-UV treatment, the external surface of the evaporative cooling pads is fortified for increased durability and allows for convenient cleaning using a pressure washer, prolonging their service life.
- The inclusion of a water circulation pump with the evaporative cooling pads facilitates achieving desired conditions even during peak summer.
· Adiabatic Intelligent Controls
- Our intelligent EC fan frequency conversion adapts to diverse onsite conditions, optimizing energy conservation.
- The force unit is designed for dry operation when water usage is restricted, ensuring uninterrupted performance.
· Options
- Enhance the coil's resistance capabilities for added durability.
- Implement coil freeze-up safeguards to ensure uninterrupted operation.
- Opt for a low noise upgrade to minimize operational sound.
- Increase redundancy levels for reliability. For bespoke requirements, please reach out to your dedicated NEWIN sales representative.
NEWIN Manufacturing Base

NEWIN FACTORY
Discover our state-of-the-art manufacturing base, strategically located in the thriving industrial heart of Huizhou, Guangdong. Encompassing a vast expanse of 10,000 square meters, our facility is a beacon of innovation and technological advancement.
ISO CERTIFICATION
Proudly holding ISO9001:2015 certification, our commitment to quality management is unwavering. Additionally, our adherence to ISO14001:2015 standards exemplifies our dedication to environmental responsibility and sustainability.
WORKSHOPS
Precision Welding Workshop
Advanced Filler Thermoforming Workshop
Cutting-Edge Sheet Metal Processing Workshop
High-Tech Cooling Tower Assembly Workshop
TESTING
Our facility boasts an Independent Testing LAB, ensuring rigorous testing protocols and quality assurance for all our products.
NEWIN COOLING TOWERS:
·
Innovative NWN/ NWF/ NCFN High-Efficiency Closed Type Cooling Tower Series
·
Reliable NSH/ NST Versatile Open Type Cooling Tower Series
·
Robust NTG Industrial Type Cooling Tower Series, designed for heavy-duty applications
·
Efficient NECN/NECH Advanced Evaporative Condenser for optimal thermal performance
·
Cutting-Edge NWFL Innovative Dry Air Cooler, engineered for precision and reliability
NEWIN takes pride in manufacturing and stocking an extensive range of essential cooling tower accessories. Our comprehensive offerings ensure maintenance and replacement needs for nearly any cooling tower size and type are met effortlessly. Reach out to customize the accessories tailored to your specific requirements.
CONTAIN:
· Robust Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Efficient Water Distribution (featuring nozzles and drift eliminators, etc.)
· Superior Heat Exchange Components (such as PVC infills, cooling coils, etc.)
· Additional Critical Accessories (including air inlet louvers, valves, etc.)
Packaging & Shipping
Experience seamless logistics with our open type cooling towers, expertly packaged and shipped to ensure safety and quality upon arrival.
Our closed type cooling towers are shipped with meticulous care, guaranteeing that every detail is protected for optimal performance when it reaches your doorstep.
Technical Strength& Standards


Certifications