Newin Cross Flow Cooling Tower with High Performance and Reliability

Product Details
Customization: Available
After-sales Service: Consult Newin Sales Representative
Warranty: Consult Newin Sales Representative
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin Cross Flow Cooling Tower with High Performance and Reliability
  • Newin Cross Flow Cooling Tower with High Performance and Reliability
  • Newin Cross Flow Cooling Tower with High Performance and Reliability
  • Newin Cross Flow Cooling Tower with High Performance and Reliability
  • Newin Cross Flow Cooling Tower with High Performance and Reliability
  • Newin Cross Flow Cooling Tower with High Performance and Reliability
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NST
Ventilation Mode
Mechanical Ventilation
Material
FRP& Hdgs
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO, CE, CTI, EAC
Condition
New
Net Weight
1030kg~ 6330kg
Running Weight
2480kg~ 19120
Transport Package
20/40/40hq Container with Loose Packing
Specification
3310mm*1800mm*3500mm~8040mm*6000mm*6210mm
Trademark
NEWIN
Origin
China
HS Code
841950
Production Capacity
15000 Sets / Year

Product Description

Experience the epitome of cooling technology with our CTI Certified Cross Flow Open Type Cooling Tower, part of the prestigious NST series. This state-of-the-art cooling tower is engineered for superior performance and unparalleled reliability, ensuring optimal cooling efficiency in every application.
Newin Cross Flow Cooling Tower with High Performance and Reliability
Product Description

NST series stands as a pinnacle of cross-flow design and an induced draft open-loop cooling tower. It's the go-to solution for small to medium industrial setups, air-conditioning systems, and mechanical ventilation projects. Ideal for projects demanding lower water quality requirements, it seamlessly integrates efficiency with reliability.

FEATURES
CTI Certified, Performance Ensured
Newin Cross Flow Cooling Tower with High Performance and Reliability

> High Efficiency Cooling
- Designed with two-sided, fully opened air intake ensuring comprehensive air engagement for maximum efficiency.
- Equipped with extensive infills to significantly enhance heat exchange efficiency, making cooling processes more effective.
- Utilizes high-frequency transverse water flow to induce strong turbulent mixing, boosting cooling efficiency remarkably.

> Maximize Resource Utilization
- Engineered to curtail water wastage, it enhances ventilation to cut down energy consumption considerably.
- Majority of its components are recyclable, reinforcing environmental sustainability while maintaining performance.

> High Impact Resistant
- The robust infills layer and internal framework are engineered for high impact resistance, minimizing risks of damage and blockage, ensuring durability.

> Ease of Operation & Maintenance
- Built with a corrosion-resistant main structure, this tower is user-friendly, easy to maintain, and operates at a lower cost, ensuring long-term value.
 
Newin Cross Flow Cooling Tower with High Performance and Reliability
MAIN PARTS

1. High Efficiency Axial Fan
> Outfitted with renowned aluminum alloy axial fans, delivering superior performance with reduced power usage and minimal noise.
> Utilizes premium quality V-belt and pulley for stable operation, simplifying maintenance procedures.
> Equipped with a TEFC cooling tower duty motor. Optional gear reducer available, with two-speed, variable speed, or explosion-proof motors as alternatives.
> Option to upgrade to a Permanent magnetic direct drive system, ensuring lower power consumption with an energy efficiency rating of up to IE5.

2. Uniform Water Distribution System
> Facilitates even water distribution through gravity, ensuring optimal performance.
> Large diameter, non-clogging PP nozzles provide extensive spraying coverage, preventing blockages.
> Features a removable steel cover for easy access, ensuring simple maintenance and inspections.
> High-low flowrate nozzles optional to guarantee uniform water distribution, even at low flow rates.
3. Integrated Baffle Type Infill
> Constructed with high-quality self-extinguishing PVC infill for safety and performance.
> Incorporates an integrated infill and drift eliminator design, maximizing heat exchange area and minimizing drift loss below 0.005%.
> Options available for high or low temperature resistant infill, catering to unique operational conditions.
4. Cold Water Basin
> The automatic makeup water system includes a stainless-steel mechanical float valve, renowned for its corrosion resistance and flexibility.
> A water basin heater can be installed as per frost protection requirements during cold seasons.
5. Heavy Duty & High Stability Structure
> Built with Z700 HDGS corrosion-resistant material, secured using 304 Stainless Steel bolts and nuts, ensuring robustness and stability.
> Optional material upgrades available in 304 / 316 Stainless Steel or NWN-Armour for enhanced durability.
6. SMC Compressed Moulded
> Constructed from fiberglass material, offering corrosion and UV resistance, ensuring longevity and reliability.
> Enhances airflow uniformity and reduces airflow resistance, optimizing fan operation for efficiency.
7. High Quality Fiberglass Panel
> Made from fiberglass material, offering exceptional corrosion and UV resistance for lasting performance.
> Our corrugated design not only enhances durability but also significantly extends the service life of the cooling tower, ensuring consistent performance over time.
> Choose from our optional 304 or 316 Stainless Steel, or opt for our robust NWN-Armour material, tailored to meet your specific needs and preferences.
8. Access Door
> Designed to facilitate effortless access for thorough tower inspection and maintenance, our access door ensures that upkeep is both efficient and straightforward.
9. Maintenance Platform
> Equipped with a state-of-the-art double layer maintenance platform, our design offers unparalleled safety and convenience for internal maintenance tasks, especially designed for seamless fan servicing.
10. Cage Ladder & Handrail
Newin Cross Flow Cooling Tower with High Performance and Reliability
 
Product Parameters

Newin Cross Flow Cooling Tower with High Performance and Reliability

Tower Model Outline dimensions (mm) Weight (Kg)
NST W L H Dry Wet
NST-18-A15-2A11-C1 3310 1800 3500 1030  2480 
NST-20-B15-2A12-C1 3310 2000 3700 1110  2730 
NST-26-D18-3A14-C1 4080 2600 4110 1660  4130 
NST-30-D21-3A16-C1 4220 3000 4540 1890  4860 
NST-33-E24-3A17-C1 4540 3300 4790 2080  5520 
NST-35-F26-4A17-C1 5350 3500 4890 2960  8290 
NST-40-F30-4B17-C1 5750 4000 4940 3310  9690 
NST-43-G32-4B18-C1 5950 4300 5140 3550  10620 
NST-46-H34-4B20-C1 6150 4600 5560 3900  11740 
NST-48-H40-5B18-C1 7420 4800 5390 4560  13970 
NST-50-I42-5B20-C1 7560 5000 5610 5190  15280 
NST-54-J42-5B22-C1 7560 5400 6010 5650  16690 
NST-60-J47-5B22-C1 8040 6000 6210 6330  19120 


Explore our Other Enhanced NST Series FRP Cooling Tower Solutions, engineered to meet various challenging working conditions seamlessly.
 
Newin Cross Flow Cooling Tower with High Performance and Reliability
Newin Cross Flow Cooling Tower with High Performance and Reliability
Newin Cross Flow Cooling Tower with High Performance and Reliability

OPTIONS
Revolutionary Permanent Magnetic Direct-Driven Fan System
Innovative Energy Saving Design

> Experience superior variable frequency control that ensures low-speed operation while achieving high efficiency and a remarkable high power factor.
> Benefit from a direct-driven fan designed to eliminate transmission losses and maintenance requirements, providing a hassle-free experience.
> Achieve unparalleled energy efficiency with a rating up to IE5, delivering notable power savings and impressive energy conservation.
Newin Cross Flow Cooling Tower with High Performance and Reliability
Newin Cross Flow Cooling Tower with High Performance and Reliability
NWN-Armour Advanced Corrosion Resistant Technology
Resilient Corrosion Resistant Design

Our galvanized steel panel, enhanced with the continuously upgraded NWN-Armour anti-corrosion coating, offers corrosion resistance comparable to Stainless Steel. This makes it an economically smart choice and a cost-effective alternative to Stainless Steel materials.

Additional Accessories to Enhance Functionality
Include premium features like a PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction to tailor your cooling tower to your specific requirements.
 
NEWIN Manufacturing Base

Newin Cross Flow Cooling Tower with High Performance and Reliability
NEWIN FACTORY
Discover the expansive manufacturing base of NEWIN, nestled in the industrial heartland of Huizhou, Guangdong. This state-of-the-art facility spans a sprawling 10,000 square meters, dedicated to excellence in every facet of production.

ISO CERTIFICATION
NEWIN proudly upholds the highest standards with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, ensuring impeccable quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Newin Cross Flow Cooling Tower with High Performance and Reliability
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Revolutionary Closed Type Cooling Tower Series, engineered for optimal efficiency and performance.
· NSH/ NST Innovative Open Type Cooling Tower Series, designed for versatility and reliability in diverse applications.
· NTG Robust Industrial Type Cooling Tower Series, crafted for heavy-duty cooling solutions.
· NECN/NECH Advanced Evaporative Condenser, for superior thermal management and energy efficiency.
· NWFL Efficient Dry Air Cooler, offering reliable performance in varied cooling requirements.

Newin Cross Flow Cooling Tower with High Performance and Reliability
At NEWIN, we manufacture and maintain an extensive inventory of essential cooling tower accessories, ready to meet the diverse maintenance and replacement needs for any size or type of cooling tower. Reach out to us for customized solutions tailored to your specific requirements.

CONTAIN:
· Comprehensive Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Advanced Water Distribution Components (featuring nozzles, drift eliminator, etc.)
· Superior Heat Exchange Elements (such as PVC infills, cooling coil, etc.)
· Additional Accessories (including air inlet louver, valve, etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Ensuring the safe and secure delivery of our remarkable open type cooling towers, we meticulously package each unit to withstand the rigors of transport. Our commitment to excellence extends beyond manufacturing to include reliable shipping solutions, ensuring your equipment arrives in pristine condition.

Newin Cross Flow Cooling Tower with High Performance and Reliability
Closed Type Cooling Towers Shipment: We take immense pride in our thoughtful shipping process for closed type cooling towers. Each unit is packaged with precision and care, guaranteeing that it reaches its destination intact and ready for seamless integration into your operations. Trust in our dedicated approach to deliver not just a product, but a promise of quality.
Newin Cross Flow Cooling Tower with High Performance and Reliability
Newin Cross Flow Cooling Tower with High Performance and Reliability
Technical Strength& Standards

Newin Cross Flow Cooling Tower with High Performance and Reliability
Newin Cross Flow Cooling Tower with High Performance and Reliability

Certifications

Newin Cross Flow Cooling Tower with High Performance and ReliabilityNewin Cross Flow Cooling Tower with High Performance and ReliabilityNewin Cross Flow Cooling Tower with High Performance and ReliabilityNewin Cross Flow Cooling Tower with High Performance and Reliability

Newin Cross Flow Cooling Tower with High Performance and Reliability


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier