Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions

Product Details
Customization: Available
Cooling Method: Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, CE, SGS
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
  • Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
  • Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
  • Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
  • Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
  • Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NAL Series
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ordinary
Material
PVC
Application Fields
Cross Flow Cooling Tower
Model--Lah
PVC
Size
65/70thicknessx Any Length X Any Width
Continuous Operation Tempperature
50 Degree Centigrade
Max.Applicationtemp. (Short Term)
60 Degree Centigrade
Color
Black
Corrugation Height
18 mm
Thickness
65/70mm
Application
Cross Flow Square Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Specification
65/70mm thickness
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

PVC Material Cooling Tower Fill Nal Air Inlet Louver

NAL series Newin NAL series air inlet louver is a remarkable productcrafted from high-strength PVC sheets, expertly bonded for durability. The surrounding frame is available in either galvanized steel or stainless steel, offering robust protection and longevity. Its innovative honeycomb inlet grille is a testament to advanced engineering, expertly optimizing airflow into the cooling tower. This design not only effectively filters impurities but also minimizes water splash, mitigating risks such as icing, nearby water damage, and unnecessary water loss.

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions

Features

Features

· Effectively prevents any debris from infiltrating your system, ensuring longevity and optimal performance.
· Ingeniously designed to prevent the splash of water droplets, maintaining a clean and efficient environment.
· Cleverly restricts sunlight penetration into cooling towers, a vital feature for minimizing algae growth.
· Significantly reduces noise emissions from the tower, contributing to a quieter and more pleasant atmosphere.
· Excels in achieving a remarkably low pressure drop result, enhancing energy efficiency.
· Designed for straightforward installation, with easy access for hassle-free cleaning and maintenance.
· Versatile in application, suitable for an extensive range of new and retrofit setups, including air inlets for package and field-erected environments.
and field-erected counter flow and straight-sided cross flow towers, fresh air make-up systems, air pollution control scrubbers.


Parameter

Properties
At Newin (Guangdong) Machinery Co., Ltd., we understand that customization is key. For the NAL Air Inlet Louver, whether it involves length, width, material, or thickness specifications, simply share your detailed requirements. We are committed to providing the perfect solution tailored to your needs. Additionally, our fill media options include flame-retardant and anti-bacterial executions, available upon request to ensure enhanced performance.

Module Length (Max)  mm 2440
Module Width (Max)  mm 600
Module Thickness  mm 65
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing
Newin goes the extra mile by supplying comprehensive structure and installation drawing guidance, coupled with jobsite storage tips and a quality control report, all delivered with your shipment. We aim to ensure that everything is perfectly in place upon arrival. Moreover, OEM or custom mold designs can be crafted to meet specific demands, available upon request to cater to unique project needs.Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions

Application

Application & Usage

Newin's EVL air inlet louver is exquisitely designed for counter flow cooling towers. It boasts SGS certification in adherence to ASTM Standards, ensuring superior quality and maximizing the cooling tower's efficiency. Simply provide us with the tower model or size for a precise estimate of the perfect air inlet louver to enhance your cooling system.
Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions


Applicable Commercial Standards
The sheet material is meticulously manufactured, strictly adhering to SGS testing in accordance with ASTM standards. Each and every property is rigorously tested, and results are available upon request to guarantee uncompromising quality across your products.

Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Air Inlet Louver Replacement
Complete the following measurement data for your cooling tower maintenance or repair projects. Trust in Newin for quality and reliability; we offer site visits and maintenance service, expertly engineered to seamlessly integrate with your cooling tower fills or components. Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions

NEWIN Manufacturing Base

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Experience the epitome of safety and efficiency with our meticulously orchestrated shipping service for open-type cooling towers. Each unit is securely enveloped in top-tier materials and cutting-edge packing methodologies, ensuring they arrive at your chosen location in flawless condition. Our steadfast commitment to protecting your valuable assets translates into comprehensive safety measures against any transit-related uncertainties. Relish the ease of our seamless transportation and timely delivery, purposefully crafted to enable your cooling solutions to become operational without delay.

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
Closed type cooling towers shipment: Delight in the peace of mind offered by our superior packaging solutions, specifically designed for closed-type cooling towers. Each unit is cocooned with exceptional care and durability to endure the most demanding transit environments, ensuring their flawless arrival and immediate deployment capability. Our relentless pursuit of excellence coupled with rapid delivery empowers you to seamlessly integrate our cutting-edge cooling technologies into your operations, eliminating any logistical concerns.
Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
Technical Strength& Standards

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions
Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions

Certifications

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry ConditionsAir Inlet Louver for Efficient Mixing Ventilation in Wet and Dry ConditionsAir Inlet Louver for Efficient Mixing Ventilation in Wet and Dry ConditionsAir Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions

Air Inlet Louver for Efficient Mixing Ventilation in Wet and Dry Conditions














Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More