Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
  • Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
  • Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
  • Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
  • Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
  • Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MAN
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Round
Noise Level
Ordinary
Application Fields
Industrial
Material
PVC or PP or UPVC
Cooling Tower Type
Counter Flow Cooling Tower
Width
915/1220mm
Lenghth (mm)
1220, 1830, 2440, Any Length
Colour
Customizable
Max. Operation Temp.
80 °c (Short Time)
Max. Appllication Temp.
60 °c (Short Time)
Transport Package
20/40/40hq Container with Loose Packing
Specification
915/1220 x any length
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

Presenting the MAN Series Counter Flow Cooling Tower Infill/Fills: Engineered for efficiency and reliability, our infill solutions are meticulously designed to optimize the performance of your cooling tower systems.

Discover the MAN Series Counter Flow Film Fill: Specifically crafted to enhance flow dynamics, our film fill is a critical component in maximizing the cooling efficiency and operational longevity of your cooling tower. Experience unparalleled performance with our infill, available in both hanging and bottom-supported configurations. The innovative crossed corrugations amplify surface area and induce turbulence, promoting exceptional heat transfer efficiency. Constructed from UV-inhibited, chemically resistant polyvinyl chloride (PVC), our fills boast outstanding hydrophilicity and minimal ventilation resistance. Offered in 915mm and 1220mm widths, they effortlessly accommodate diverse cooling tower specifications and are compatible with any counter flow cooling tower worldwide.

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Features

Features

· With cutting-edge technology and a thoughtfully engineered design, Newin Cooling Tower Fills ensure an outstanding cooling effect.
· Offering superior ventilation with minimal resistance, these fills boast excellent hydrophilicity, a large contact area, and exceptional film-forming capabilities. They are easy to pack and provide superior heat conductivity. With impressive chemical stability, they resist corrosion from acids, alkalis, and organic solvents alike.
· Our innovative staggered ring material form allows for seamless assembly. Typically packed at a 60° angle, we offer two types of materials: polyvinyl chloride (PVC) and polypropylene (PP), each ensuring robust performance.



Picture in detail

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Parameter

Properties

For all your specific requirements regarding MAN film fill—be it length, width, materials, or thickness—please provide us with your detailed specifications. Our expert team at Newin is fully equipped to accommodate all customer needs. We also offer fill media crafted with flame-retardant or anti-bacterial properties upon request, ensuring your project meets the highest safety and quality standards.
Module Length (Max.)  mm 3660
Module Width   mm 915 / 1220
Module Depth   mm -
Flute Height  mm 19
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.38
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing

Newin is committed to ensuring a seamless experience by providing comprehensive structure and installation drawing advice, coupled with jobsite storage tips and a thorough quality control report at the time of shipment. We attend to every detail so you can focus on your project. Moreover, we offer OEM services and special mold designs tailored to your specific requests, making sure that every aspect of your project is covered to perfection.Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Application

Application & Usage

The versatile Newin MAN Film Fill is expertly designed to adapt with precision to various counter flow cooling tower series from other leading brands, such as: MD, CP, MC Series and many more across the globe. Rigorously tested to SGS standards, our infill ensures unparalleled quality, maximizing the cooling efficiency of your towers. Simply share your tower model or dimensions with us, and we will precisely calculate the number of sheets required for your tower's replacement needs.
Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation

Applicable Commercial Standards

Our sheet materials are meticulously engineered to comply with SGS tests and ASTM standards, guaranteeing superior quality and consistency. Whether you require testing of individual properties or a comprehensive assessment of all characteristics, we provide these upon request for your assurance.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Counter Flow Film Fill Replacement

Provide the detailed measurements below for your cooling tower maintenance or repair projects. When you demand excellence and dependability, rely on Newin. We offer site visits and maintenance services, ensuring our engineering solutions seamlessly integrate with your cooling tower fills and components.
Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Options

You May Also Find These Interesting: Explore additional innovative offerings that complement your current selection

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
NEWIN Manufacturing Base

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
NEWIN FACTORY
Embark on a captivating journey to our cutting-edge manufacturing base, strategically situated in the bustling industrial heartland of Huizhou, Guangdong. Spanning an impressive 10,000 square meters, our facility is a shining beacon of innovation, excellence, and the latest technological advancements.

ISO CERTIFICATION
We proudly emphasize our steadfast commitment to unparalleled quality and environmental responsibility with our esteemed ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting a benchmark for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unmatched efficiency and innovation with our Closed Type Cooling Tower Series, meticulously crafted to deliver superior performance and unparalleled reliability. Each model represents the pinnacle of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the exceptional capabilities of our Industrial Type Cooling Tower Series, specifically crafted to tackle heavy-duty and demanding applications, ensuring resilience and power in every situation.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new benchmarks in performance and operational excellence, transforming the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
NEWIN is your trusted partner in providing premier cooling tower solutions, offering a comprehensive range of accessories to meet your maintenance and replacement needs. Customize your selection to suit a wide variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Discover the pinnacle of secure and efficient transportation with our exquisitely designed open-type cooling towers. Each tower is expertly packaged with the highest quality materials and employs sophisticated packing techniques, ensuring a flawless delivery in pristine condition. Our unwavering dedication to safety and security provides unmatched protection against any potential transit damages. Experience seamless logistics and prompt delivery, all orchestrated to have your cooling solutions operational without any delays. With Newin Cooling Tower Fills, Optimal Design for Mixing Ventilation, rest assured that your investment is in the safest hands.

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Closed type cooling towers shipment: Revel in the unparalleled assurance offered by our top-of-the-line packaging solutions for closed-type cooling towers. Each unit is meticulously and securely encased to withstand the rigors of transportation, ensuring they reach their destination unblemished and fully operational. Our unyielding commitment to superior quality control and expedient shipping empowers you to concentrate on leveraging our state-of-the-art cooling technology for your unique requirements, free from logistical concerns. Trust Newin Machinery Co., Ltd. for excellence in delivery and performance, tailored to elevate your business success.
Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Technical Strength& Standards

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation
Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation

Certifications

Newin Cooling Tower Fills: Optimal Design for Mixing VentilationNewin Cooling Tower Fills: Optimal Design for Mixing VentilationNewin Cooling Tower Fills: Optimal Design for Mixing VentilationNewin Cooling Tower Fills: Optimal Design for Mixing Ventilation

Newin Cooling Tower Fills: Optimal Design for Mixing Ventilation





Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups