Newin 145mm Cooling Tower Drift Eliminator For Evapco Cooling Tower
NEWIN EVD eliminators
Drift eliminators remove small droplets of water that are entrained in the exhaust air to minimize the nuisance and health issues that they create if allowed to escape through the top of the tower along with the heated air. Drift eliminators are designed to create a tortuous path for the air stream. When the water droplets move through them, they are forced to change direction and impact the drift eliminator side walls, coalescing and draining back into the wet section of the cooling tower.
The drift eliminators are constructed of an inert polyvinyl chloride (PVC) plastic material which effectively eliminates corrosion of these vital components. They are assembled in sections to facilitate easy removal for inspection of the water distribution system.
EVD-145 Eliminator
Feaures
- Anti-aging, high water absorption
- low airflow resistance, high strength
- easy installation and long service life
- can be the replacement of air inlet louver
Specification
Model--EVD |
PVC |
Max.length |
depend on customer demand |
Width |
depend on customer demand |
Height |
145mm |
Continuous operation tempperature |
50ºC |
Max.applicationtemp. (short term) |
60ºC |
Color |
Black |
Application |
Counter flow cooling tower |
Packing and Loading: LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs
EVD drift eliminator Pictures --- cooling tower drift eliminator
Packing & Shipment
Physical and mechanical property
PVC Plastic sheet(after molding) Physical and mechanical property
No. |
Item |
symbol |
unit |
index |
test method |
1 |
density |
ρ |
g/cm3 |
≤1.55 |
GB/T 1033 1-2008 |
2 |
tensile strength |
lengthways |
σt |
MPa |
≥42.0 |
GB/T 13022-91 |
crosswise |
≥38.0 |
3 |
tear strength |
lengthways |
σtr |
kN/m |
≥150 |
GB/T 1130-91 |
crosswise |
≥160 |
4 |
Folded in half Coldness Resistance Temperature |
ordinary type |
tb |
ºC |
≤-8 |
DL/T 742-2001 |
Frigostabile type |
≤-18 |
5 |
oxygen index |
OI |
-- |
≥30 |
GB/T 2406 1-2008 |
Replacement for other brand cooling towers:
Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.
You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver,
please visit to below website below for more details.
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
Contact person
Erin Lian
*******************************************
Website : http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com