Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
  • Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
  • Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
  • Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
  • Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
  • Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
Find Similar Products
  • Overview
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MBD
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC
Transport Package
Wooden Case or 20gp/40gp Container
Specification
Height: 146 mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

Our specially engineered Drift Eliminator is crafted specifically for optimal performance in cooling tower environments, ensuring efficient operation and peak functionality.

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers

MBD Newin The MBD cellular drift eliminator is an innovative solution, expertly designed to effectively capture and remove minuscule water droplets entrained within the exhaust air. This minimizes potential nuisances and health hazards by preventing these droplets from escaping through the cooling tower's top along with the heated air. The MBD series drift eliminators ingeniously create a complex path for the airstream. As water droplets traverse through, they are expertly redirected, impacting the eliminator's side walls, coalescing, and efficiently draining back into the wet section of the cooling tower.
 


FEATURES

- Crafted from materials with exceptional anti-aging properties and superior water absorption capabilities.
- Engineered for low airflow resistance while maintaining outstanding structural strength.
- Designed for effortless installation and renowned for its extended service life.
- Versatile enough to serve as a replacement for the air inlet louver, offering enhanced functionality.
Parameter

PROPERTIES

With a variety of customizable options available in MBD drift eliminators-such as varying lengths, widths, materials, and thicknesses-it's simple to tailor our products to meet your specific needs. Share your detailed specifications with us, and Newin will deliver the perfect solution and competitive offer. Additionally, flame-retardant or anti-bacterial fill media can be provided upon request to ensure enhanced safety and hygiene.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Height  mm 146
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.38
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.



STRUCTURE & INSTALLATION DRAWING

Newin provides detailed structure and installation drawings, alongside valuable jobsite storage suggestions and comprehensive quality control reports with every shipment. This ensures that customers are well-prepared upon receipt of materials. For those with unique requirements, OEM services and special mold designs are also available upon request.

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
Application

APPLICATION & USAGE

The Newin MBD cellular drift eliminator is designed with precision to seamlessly replace components in cooling towers. It has undergone rigorous SGS testing in accordance with ASTM Standards, ensuring top-notch infill quality for maximum cooling tower efficiency. Simply provide us with your tower model or size, and we will accurately estimate the number of sheets required for your cooling tower replacement, ensuring a flawless fit.Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers


Applicable Commercial Standards

Our sheet materials adhere strictly to the SGS testing protocols in line with ASTM standards. Each property, or collectively all properties as outlined below, are available for testing upon request, ensuring our product meets your precise specifications.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Cellular Drift Eliminator Replacement

Input the measurements below for your cooling tower maintenance or repair projects. When it comes to demanding quality and reliability, trust Newin. We offer site visits and maintenance services that are expertly engineered to suit your cooling tower fills and components, ensuring unmatched performance and peace of mind.
Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
NEWIN Manufacturing Base

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
NEWIN FACTORY
Embark on an awe-inspiring journey through our state-of-the-art manufacturing base, strategically nestled in the dynamic industrial hub of Huizhou, Guangdong. Spanning an expansive 10,000 square meters, this facility stands as a beacon of innovation and technological advancement. Immerse yourself in an environment where pioneering breakthroughs meet excellence, consistently setting new standards in the realm of manufacturing.

ISO CERTIFICATION
We proudly highlight our steadfast commitment to unrivaled quality and environmental stewardship, underscored by our prestigious ISO certifications: ISO9001:2015 Quality Management and ISO14001:2015 Environmental Management. These certifications epitomize our unwavering dedication to setting industry benchmarks for excellence and sustainable practices.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unparalleled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series. Each model is crafted with meticulous attention to deliver superior performance and unmatched reliability, embodying the zenith of cooling tower technology.
· NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance. These towers set the bar high in the industry, consistently exceeding expectations for enduring excellence.
· NTG Explore the astonishing capabilities of our Industrial Type Cooling Tower Series, specifically crafted to tackle even the most demanding heavy-duty applications. These towers ensure resilience and power at every turn, meeting the challenges of the most rigorous environments.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These models set new standards in performance and operational excellence, revolutionizing the cooling industry with unmatched innovation.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler. Expertly designed for superior airflow and maximum efficiency, this cooler optimizes every aspect of cooling, delivering unparalleled results.

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
NEWIN is your trusted partner in premier cooling tower solutions, offering a comprehensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a variety of cooling tower sizes and types. Reach out to us to tailor the perfect suite of accessories for optimal cooling tower performance.

CONTAIN:
· A robust Fan drive system, featuring a fan, fan stack, reducer, motor, and shaft. Designed with an emphasis on durability and precision, this system ensures seamless and efficient operation.
· Highly efficient Water distribution components, with precision-engineered nozzles and advanced drift eliminators. These components elevate water management for superior performance.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils. Meticulously crafted for optimal performance and energy efficiency, these options enhance thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system. These accessories boost overall functionality and efficiency, elevating performance to new heights.
 
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, ensuring they reach you in immaculate condition. We prioritize the utmost safety and security, employing premium materials and strategic packing techniques to provide an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, ensuring that your cooling solutions become operational without delay for maximum efficiency and performance.

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
Closed type cooling towers shipment: Experience peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to endure the rigors of transport, ensuring arrival at your site in pristine condition and ready to deliver top-tier performance. Our steadfast dedication to quality control and punctual shipping empowers you to concentrate on what truly matters - harnessing our cutting-edge cooling technology to enhance your applications and achieve unparalleled outcomes.
Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
Technical Strength& Standards

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers
Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers

Certifications

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling TowersNewin Mbd Series Drift Eliminator for Natural Ventilation Cooling TowersNewin Mbd Series Drift Eliminator for Natural Ventilation Cooling TowersNewin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers

Newin Mbd Series Drift Eliminator for Natural Ventilation Cooling Towers



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More