Innovative Air Cooler for Optimal Dry Cooling Solutions

Product Details
Customization: Available
Ventilation Mode: Mechanical Ventilation
Material: Metal

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Innovative Air Cooler for Optimal Dry Cooling Solutions
  • Innovative Air Cooler for Optimal Dry Cooling Solutions
  • Innovative Air Cooler for Optimal Dry Cooling Solutions
  • Innovative Air Cooler for Optimal Dry Cooling Solutions
  • Innovative Air Cooler for Optimal Dry Cooling Solutions
  • Innovative Air Cooler for Optimal Dry Cooling Solutions
Find Similar Products
  • Overview
  • Features
  • Working Principle
  • Parameter
  • Components& Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWFL-V
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
207~936kw
Transport Package
20/40/40hq Container
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000

Product Description

NEWIN High-Capacity Dry Air Cooler: Elevate Your Cooling Experience with Cutting-Edge Innovation. Discover unparalleled performance and efficiency with our advanced cooling solutions, designed to redefine comfort and reliability.


NWFL-V The NWFL-V series exemplifies the pinnacle of modern engineering with its V-type dry air cooler, meticulously crafted with a state-of-the-art Free Cooling System. This cutting-edge system promises efficient cooling performance, making it the ideal choice for HVAC systems and various facilities. Importantly, it achieves superior cooling without consuming water, setting it apart from traditional evaporative cooling methods.

Innovative Air Cooler for Optimal Dry Cooling Solutions
Features
· Ingeniously crafted V-type design coupled with a sophisticated Free Cooling System, offering unparalleled efficiency.
Experience exceptional cooling performance with our high-efficiency system that operates without water consumption, ensuring sustainability and cost-effectiveness.

· Equipped with optimal components such as the state-of-the-art EC motor, designed to provide superior efficiency and reliability.
Harness the pinnacle of system efficiency, delivering maximum energy savings for unmatched performance.

· Large redundancy engineered to perfection, ensuring consistent performance without any thermal efficiency loss.
Our system boasts high reliability, allowing for seamless operation and ease of maintenance, reducing downtime and operational costs.

· Designed for robustness and straightforward maintenance, ensuring your investment is protected while simplifying upkeep.
Innovative Air Cooler for Optimal Dry Cooling Solutions
 
Working Principle

Innovative Air Cooler for Optimal Dry Cooling Solutions
When NWFL-V adiabatic cooler is in operation:
The EC fan system ingeniously draws in refreshingly cool, dry air, which gracefully makes its way into the tower through the advanced V-shaped finned tube heat exchanger. This V-shaped marvel features a large contact surface that significantly accelerates the cooling process for both the air and the hot process fluid, resulting in a remarkable enhancement in heat exchange efficiency. Through the process of extensive partition wall heat exchange with the cool, dry air, the hot saturated air is expelled from the tower, effectively achieving efficient Free Cooling, a non-evaporative and highly eco-friendly cooling solution.

Series Type Capacity 1. Fan Drive System 2. Heat Exchange System
NWFL-V V Range EC axial fans Finned coil
Maximum thermal performance 207~936kw Intelligent frequency conversion, 
more energy saving
Maximum heat transfer surface
Free cooling 
system
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption.
Application Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc.
 
Parameter
 
Innovative Air Cooler for Optimal Dry Cooling Solutions
Model Cooling Capacity Total Dimension Fan Weight
L W H Nos of Fans Noise Level Power Shipping Operation
kw mm mm mm Nos dB(A) kw kg kg
NWFL-231-4D10-800V 200 2740 2050 2190 4 79.4 3.14  1187  1386 
NWFL-231-6D10-800V 250 2740 2050 2190 4 82.7 3.76  1332  1586 
NWFL-231-8D10-800V 290 2740 2050 2190 4 87.8 4.89  1477  1786 
NWFL-241-4D10-800V 255 2740 2050 2550 4 80 4.43  1329  1590 
NWFL-241-6D10-800V 315 2740 2050 2550 4 81.8 5.47  1522  1854 
NWFL-241-8D10-800V 360 2740 2050 2550 4 84.5 6.49  1714  2119 
NWFL-251-4D10-800V 310 2740 2050 2980 4 81.5 6.44  1493  1817 
NWFL-251-6D10-800V 400 2740 2050 2980 4 83 7.61  1732  2146 
NWFL-251-8D10-800V 450 2740 2050 2980 4 85 8.81  1971  2475 
NWFL-261-4D10-900V 375 2740 2250 3300 4 80.8 7.37  1675  2060 
NWFL-261-6D10-900V 470 2740 2250 3300 4 84.9 8.35  1961  2453 
NWFL-261-8D10-900V 535 2740 2250 3300 4 86.4 9.75  2247  2847 
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
Innovative Air Cooler for Optimal Dry Cooling Solutions
· Heavy-duty Construction

Our galvanized steel panels, enhanced with NEWIN Armour anti-corrosion coating, offer resilience and corrosion resistance nearing that of stainless steel. This allows the Robust Adiabatic Cooling System to operate efficiently with higher concentration cycles, significantly reducing water consumption. Plus, the coating is easily repairable if damaged, ensuring longevity and efficient maintenance.
· V Type Finned Coil Heat Exchanger

Crafted with precision, our finned coil heat exchanger features copper tubes and aluminum fins, perfectly spaced for optimal heat exchange performance. The innovative brazing of copper tubes to coil headers and flaring to the finned coil ensures seamless thermal conduction and superior heat transfer capabilities.
Innovative Air Cooler for Optimal Dry Cooling Solutions
Innovative Air Cooler for Optimal Dry Cooling Solutions
· EC Axial Fan

- Our advanced EC motor with a straight-shaft drive is built for resilience, boasting IP55 protection and F insulation grades, ideal for continuous operation in hot, humid climates. It ensures smooth performance with exceptional energy efficiency, meeting or exceeding IE4 standards.

- Featuring durable tapered roller bearings, our fans offer remarkable load-bearing capabilities and a service life surpassing 20,000 hours, promising reliability and sustained performance.

- Meticulously tested for minimal noise, our fans maintain excellent heat exchange capabilities. With PFC technology, they keep harmonics under 35%, guaranteeing that the EC fan system achieves high static efficiency even at lower speeds.
· Adiabatic Intelligent Controls

- Intelligent frequency conversion of EC fans adapts to various onsite conditions, optimizing energy savings.

- Operates efficiently in dry mode when water use is restricted.
Innovative Air Cooler for Optimal Dry Cooling Solutions

 

· Options

- Enhance coil resistance capabilities for greater durability.
- Implement coil freeze-up safeguards for enhanced protection.
- Upgrade to low noise operation for quieter performance.
- Increase redundancy levels for improved reliability.
NEWIN Manufacturing Base

Innovative Air Cooler for Optimal Dry Cooling Solutions
NEWIN FACTORY
Nestled in the vibrant and thriving city of Huizhou, Guangdong, our expansive manufacturing base covers an awe-inspiring area of 10,000 square meters. This state-of-the-art facility provides an unparalleled environment that fosters innovation and excellence in every phase of production.

ISO CERTIFICATION
Proudly holding prestigious ISO certifications, including ISO9001:2015 for Quality Management Systems and ISO14001:2015 for Environmental Management Systems, Newin embodies an unwavering commitment to delivering superior quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Innovative Air Cooler for Optimal Dry Cooling Solutions
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience the pinnacle of innovation with our Closed Type Cooling Tower Series, meticulously engineered for unmatched performance and efficiency.
· NSH/ NST Introducing our highly efficient Open Type Cooling Tower Series, crafted to address a myriad of diversified applications with precision.
· NTG Discover the ultimate in durability and strength with our Industrial Type Cooling Tower Series, specifically designed for the most demanding industrial environments.
· NECN/NECH Explore our sophisticated Evaporative Condenser systems, engineered to provide superior cooling efficiency and performance.
· NWFL Introducing our innovative Dry Air Cooler solutions, delivering outstanding high-capacity and energy-efficient cooling performance.

Innovative Air Cooler for Optimal Dry Cooling Solutions
NEWIN proudly offers a comprehensive range of premium cooling tower accessories, meticulously designed to meet maintenance and replacement needs across a wide array of cooling tower sizes and configurations. Contact us today to customize the exact cooling tower accessories that will meet your unique requirements.

CONTAIN:
· Fan drive system components encompassing fan, fan stack, reducer, motor, and shaft, all expertly crafted to elevate functionality and performance.
· Water distribution components such as nozzles and drift eliminators, designed to optimize fluid management and efficiency.
· Heat exchange components featuring PVC infills and cooling coils, ensuring superior and efficient thermal transfer.
· Additional accessories including air inlet louvers and valves, meticulously engineered to facilitate seamless integration and functionality.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience the pinnacle of seamless transit with our expertly orchestrated shipping solutions. We guarantee that your equipment arrives not only on time but also in immaculate condition, reflecting our commitment to excellence and reliability.

Innovative Air Cooler for Optimal Dry Cooling Solutions
Closed Type Cooling Towers Shipment: Discover unparalleled assurance with our secure and efficient delivery service. Our meticulous handling process ensures that your valuable assets are safeguarded at every step of their journey, providing peace of mind and unmatched confidence.
Innovative Air Cooler for Optimal Dry Cooling Solutions
Innovative Air Cooler for Optimal Dry Cooling Solutions
Technical Strength& Standards

Innovative Air Cooler for Optimal Dry Cooling Solutions
Innovative Air Cooler for Optimal Dry Cooling Solutions

Certifications

Innovative Air Cooler for Optimal Dry Cooling SolutionsInnovative Air Cooler for Optimal Dry Cooling SolutionsInnovative Air Cooler for Optimal Dry Cooling SolutionsInnovative Air Cooler for Optimal Dry Cooling Solutions

Innovative Air Cooler for Optimal Dry Cooling Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More