Single Reduction Gear Reducer Supplied for Marley Cooling Towers

Product Details
Customization: Available
Cooling Method: Counter Flow or Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, CE
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Single Reduction Gear Reducer Supplied for Marley Cooling Towers
  • Single Reduction Gear Reducer Supplied for Marley Cooling Towers
  • Single Reduction Gear Reducer Supplied for Marley Cooling Towers
  • Single Reduction Gear Reducer Supplied for Marley Cooling Towers
  • Single Reduction Gear Reducer Supplied for Marley Cooling Towers
  • Single Reduction Gear Reducer Supplied for Marley Cooling Towers
Find Similar Products
  • Overview
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
Single Reduction Gear Reducer
Condition
New
Ventilation Mode
Natural Ventilation
Material
Metal
Air Contact Form
Dry
Air Contact Way
Open
Noise Level
Low
Application Fields
Industrial
Tower Shape
Round and Square
Transport Package
Wooden Case
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
5000000

Product Description

Amarillo single reduction gear reducer supplied for Marley cooling towers
- The drives Amarillo Gear Company LLC produces for cooling tower, design features and ratings are in accordance with, or exceed, the minimum requirements of AG MA (American Gear Manufacturers Association) and CTI (Cooling Technology Institute) standards. Service Factor= 2.0. The wide application in many brands cooling towers, like Marley, BAC, EVAPCO etc.Single Reduction Gear Reducer Supplied for Marley Cooling Towers

Housing and Castings

Castings are rigidly designed and constructed to absorb internal and external loads with minimum deflection. Gear cases are pre-drilled with pilot holes to assist in installation of dowel pins.
 

Spiral Bevel Gears

Designed and manufactured by Amarillo Gear Company LLC for fan drive service.All spiral bevel gears are precision machined from high grade alloy steel, case hardened and lapped in pairs.
 

Helical Gears

Helical gears are designed specifically for fan drive service and are precision machined from high grade alloy steel, case hardened and precision ground to provide low-noise, low vibration operation.
 

Bearings

Amarillo Gear is an industry leader with L10a bearing life exceeding 100,000 hours on all bearings. Input and intermediate bearings provide double the service life specified in AG MA and CTI standards, resulting in lower maintenance costs. The fan shaft bearings are designed to carry all loads imposed by the fan while maintaining this outstanding bearing life. Only trusted name brand bearings such as Timken and SKF are installed in Amarillo fan drives.
 

Quiet Operation

Quiet operation of the Amarillo Fan Drives is achieved through careful design and controlled manufacturing methods of components.
 

Shaft Seals

Both the input and output shaft openings have 2 spring-loaded, single-lip seals to keep outside contamination from entering the gearbox.
 

Lubrication

Oversized slinger on the input shaft provides excellent lubrication in either direction or at half speed operation.
 

Low Speed Operation

For operation when motor speeds are less than 450 rpm, single reduction fan drives require Amarillo Gear's exclusive KLow Speed" option, and double reduction fan drives require a mechanical oil pump for proper lubrication. The addition of these options allow operation with no minimum input speed restrictions.
 

Service Openings

Large inspection opening facilitates periodic inspections.

TABLE 1.- SINGLE REDUCTION
Service Horsepower Ratings (HP) at (Service Factor = 2.0)
Model Input
(RPM)
Ratio* Nominal Ratio (See Table 2. for exact ratio)
2.0 2.5 3.0 3.25 3.5 3.75 4.0  4.25 4.5 4.75 5.0 5.5 6.0 6.5 7.0  7.5 8.0 8.5  9.0 9.5
65 1750
1450
1160
25
21
17
25
21
17
20
17
13
18
15
12
17
14
11
  15
12
10
  12
10
8
  10
8
7
                 
85 1750
1450
1160
  48
40
32
45
37
30
43
36
29
39
32
26
36
30
24
33
27
22
32
26
21
28
23
19
27
22
18
25
21
17
20
17
13
18
15
12
15
12
10
15
12
10
         
110 1750
1450
1160
        75
62
50
74
61
49
72
60
48
71
59
47
69
57
46
64
53
42
60
50
40
46
38
30
40
33
27
33
27
22
30
25
20
25
21
17
24
20
16
     
135 1750
1450
1160
            110
91
73
  93
77
62
88
73
58
83
69
55
71
59
47
65
54
43
59
49
39
48
 40
 32
43
36
29
42
35
28
35
29
23
30
25
20
 
155 1750
1450
1160
                    110
91
73
100
83
66
90
75
60
85
70
56
75
 62
 50
65
54
43
55
 46
 36
50
 41
 33
45
 37
 30
 
175 1750
1450
1160
                    133
110
88
126
104
84
112
93
74
105
87
70
100
 83
 66
80
66
53
60
50
40
60
50
40
60
 50
 40
50
41
33
 
TABLE 2.- EXACT RATIO
Model 2.0   2.5  3.0 3.25  3.5 3.75 4.0 4.25 4.5 4.75  5.0 5.5   6.0   6.5 7.0 7.5 8.0 8.5   9.0 9.5
65 2.00  2.47 2.94 3.27 3.54   3.92   4.55   4.90                  
85    2.56 3.00 3.23 3.50 3.75 4.00 4.27 4.55 4.70 5.00 5.56 6.00  6.56 7.00          
110         3.46 3.77 4.00 4.25 4.45 4.73 5.00 5.50 6.00  6.56 7.00 7.50 8.00      
135             4.00   4.50 4.73 5.00 5.50 6.00  6.56 7.00 7.50 8.00 8.57 9.00  
155                     5.08 5.58 6.00  6.56 7.11 7.56 8.00 8.50 9.00  
175                     5.08 5.58 6.09  6.60 7.10 7.56 8.13 8.50 9.14 9.57

Main information need to be provided for supplying:Motor power &Reduction ratio
Installation size ( customized): out put shaft length, shaft diameter & key ( width x depth)
If any special requirements, please consult NEWIN sales representative.
 

 NEWIN supplys kinds of superior gear reducer for different cooling tower fan drive systems 
Single Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling Towers

OPTIONS
Revolutionary Permanent Magnetic Direct-Driven Fan System
Innovative Energy Saving Design

> Experience superior variable frequency control that ensures low-speed operation while achieving high efficiency and a remarkable high power factor.
> Benefit from a direct-driven fan designed to eliminate transmission losses and maintenance requirements, providing a hassle-free experience.
> Achieve unparalleled energy efficiency with a rating up to IE5, delivering notable power savings and impressive energy conservation.
Single Reduction Gear Reducer Supplied for Marley Cooling Towers
Single Reduction Gear Reducer Supplied for Marley Cooling Towers
NWN-Armour Advanced Corrosion Resistant Technology
Resilient Corrosion Resistant Design

Our galvanized steel panel, enhanced with the continuously upgraded NWN-Armour anti-corrosion coating, offers corrosion resistance comparable to Stainless Steel. This makes it an economically smart choice and a cost-effective alternative to Stainless Steel materials.

Additional Accessories to Enhance Functionality
Include premium features like a PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction to tailor your cooling tower to your specific requirements.
 
NEWIN Manufacturing Base

Single Reduction Gear Reducer Supplied for Marley Cooling Towers
NEWIN FACTORY
Discover the expansive manufacturing base of NEWIN, nestled in the industrial heartland of Huizhou, Guangdong. This state-of-the-art facility spans a sprawling 10,000 square meters, dedicated to excellence in every facet of production.

ISO CERTIFICATION
NEWIN proudly upholds the highest standards with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, ensuring impeccable quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Single Reduction Gear Reducer Supplied for Marley Cooling Towers
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Revolutionary Closed Type Cooling Tower Series, engineered for optimal efficiency and performance.
· NSH/ NST Innovative Open Type Cooling Tower Series, designed for versatility and reliability in diverse applications.
· NTG Robust Industrial Type Cooling Tower Series, crafted for heavy-duty cooling solutions.
· NECN/NECH Advanced Evaporative Condenser, for superior thermal management and energy efficiency.
· NWFL Efficient Dry Air Cooler, offering reliable performance in varied cooling requirements.

Single Reduction Gear Reducer Supplied for Marley Cooling Towers
At NEWIN, we manufacture and maintain an extensive inventory of essential cooling tower accessories, ready to meet the diverse maintenance and replacement needs for any size or type of cooling tower. Reach out to us for customized solutions tailored to your specific requirements.

CONTAIN:
· Comprehensive Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Advanced Water Distribution Components (featuring nozzles, drift eliminator, etc.)
· Superior Heat Exchange Elements (such as PVC infills, cooling coil, etc.)
· Additional Accessories (including air inlet louver, valve, etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Ensuring the safe and secure delivery of our remarkable open type cooling towers, we meticulously package each unit to withstand the rigors of transport. Our commitment to excellence extends beyond manufacturing to include reliable shipping solutions, ensuring your equipment arrives in pristine condition.

Single Reduction Gear Reducer Supplied for Marley Cooling Towers
Closed Type Cooling Towers Shipment: We take immense pride in our thoughtful shipping process for closed type cooling towers. Each unit is packaged with precision and care, guaranteeing that it reaches its destination intact and ready for seamless integration into your operations. Trust in our dedicated approach to deliver not just a product, but a promise of quality.
Single Reduction Gear Reducer Supplied for Marley Cooling Towers
Single Reduction Gear Reducer Supplied for Marley Cooling Towers
Technical Strength& Standards

Single Reduction Gear Reducer Supplied for Marley Cooling Towers
Single Reduction Gear Reducer Supplied for Marley Cooling Towers

Certifications

Single Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling TowersSingle Reduction Gear Reducer Supplied for Marley Cooling Towers

Single Reduction Gear Reducer Supplied for Marley Cooling Towers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier