Unleash Superior Efficiency with Our High-Capacity Dry Air Cooler: The Pinnacle of Innovative Cooling Solutions
NWFL-V The NWFL-V series stands as the epitome of V-type dry air coolers, engineered meticulously with a state-of-the-art Free Cooling System. Revel in its exceptional cooling performance, making it the ideal choice for HVAC systems and a variety of other facilities. Enjoy the unparalleled advantage of non-water consumption, setting a new standard over traditional evaporative cooling methods.
Features
· Ingenious V-type design complemented by an innovative Free Cooling System,
Ensures remarkable cooling efficiency while eliminating the need for water consumption.
· Superiorly crafted with optimal efficiency components such as the advanced EC motor,
Guarantees unparalleled system efficiency with maximum energy savings achieved.
· Generous redundancy options available,
This feature impeccably eliminates any potential loss in thermal performance.
· Boasts exceptional reliability and is designed for effortless maintenance.
Working Principle

When the NWFL-V adiabatic cooler is in operation:
The innovative EC fan system ingeniously draws in refreshing cool dry air that seamlessly enters the tower through the specialized V-shaped finned tube heat exchanger. This unique V-shaped design offers an expansive contact surface, substantially enhancing the cooling process for both the air and the heated process fluid, which results in a remarkable boost in heat exchange efficiency. Following an extensive partition wall heat exchange with the invigorating cool dry air, the hot saturated air is efficiently discharged from the tower, achieving an optimal state of Free Cooling (non-evaporative cooling).
Series |
Type |
Capacity |
1. Fan Drive System |
2. Heat Exchange System |
NWFL-V |
V |
Range |
EC axial fans |
Finned coil |
Maximum thermal performance |
207~936kw |
Intelligent frequency conversion,
more energy saving |
Maximum heat transfer surface |
Free cooling
system |
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption. |
Application |
Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc. |
Parameter
Model |
Dry Cooling |
Fan Motor |
Dimension (mm) |
Weight |
Fluid flow |
Cooling capacity |
Power |
L |
W |
T |
Shipping |
Operation |
m³/h |
kW |
kW |
mm |
mm |
mm |
kg |
kg |
NWFL-270V |
40 |
207 |
6.317 |
3750 |
2050 |
2156 |
1477 |
1633 |
NWFL-400V |
54 |
279 |
6.887 |
3750 |
2050 |
2206 |
1651 |
1885 |
NWFL-540V |
67 |
346 |
7.835 |
3750 |
2050 |
2246 |
1825 |
2137 |
NWFL-490V |
71 |
367 |
10.797 |
5000 |
2050 |
2534 |
2118 |
2400 |
NWFL-730V |
97 |
502 |
13.118 |
5000 |
2050 |
2581 |
2415 |
2838 |
NWFL-970V |
120 |
620 |
15.889 |
5000 |
2050 |
2613 |
2712 |
3276 |
NWFL-770V |
113 |
584 |
18.569 |
6250 |
2050 |
2951 |
2643 |
3086 |
NWFL-1150V |
152 |
786 |
23.522 |
6250 |
2050 |
2987 |
3079 |
3744 |
NWFL-1530V |
181 |
936 |
25.605 |
6250 |
2050 |
3011 |
3515 |
4402 |
Important Note:
1. Incomparable Standard Design Working Condition: Experience optimal performance with a fluid in/out temperature set at an efficient 46/41ºC, sculpted for excellence.
2. Precision in Standard Design: Benefit from a meticulously crafted ambient wet/dry bulb temperature of 21/31ºC, engineered for peak efficiency.
3. The data sheet above reflects the conditions using a 40% ethylene glycol solution fluid, ensuring reliability and consistency in all operations.
4. For tailored solutions that deviate from the standard design conditions, please reach out to your dedicated NEWIN sales representative. Let's customize your experience!
Components& Options
· Heavy-duty Construction
Crafted with galvanized steel panels enhanced by NEWIN Armour's cutting-edge anti-corrosion coating, our construction boasts remarkable durability. This revolutionary coating mimics the robust characteristics of stainless steel, allowing equipment to function efficiently in higher concentration cycles, significantly reducing water consumption. Furthermore, the coating is designed for easy repairs if any damage occurs, ensuring long-lasting effectiveness.
· V Type Finned Coil Heat Exchanger
Our V Type finned coil heat exchanger is a marvel of engineering, utilizing copper tubes paired with precisely spaced aluminum fins for optimal heat exchange. The copper tubes are expertly brazed to the coil headers and meticulously flared to the finned coil, ensuring seamless thermal conductivity and unparalleled performance.
· EC Axial Fan
- Our EC motor's straight-shaft drive is an industry leader, offering IP55 protection and F grade insulation, ideal for withstanding the challenges of prolonged operation in hot, humid climates. It achieves outstanding energy efficiency, meeting or exceeding IE4 standards for optimal operational excellence.
- Designed with durable tapered roller bearings, our fans demonstrate superior load-bearing capability and offer an impressive lifespan surpassing 20,000 operational hours, guaranteeing reliable performance and durability.
- Through meticulous static and dynamic testing, we minimize noise while maintaining exceptional heat exchange performance. Equipped with PFC technology, we ensure harmonics stay under 35%, allowing our EC fan system to sustain high static efficiency even at lower speeds.
· Adiabatic Intelligent Controls
- With EC fans powered by intelligent frequency conversion, our systems adapt seamlessly to diverse on-site conditions, optimizing energy savings and operational efficiency.
- Designed for dry operation when water usage is not permissible, ensuring continuous performance without compromise.
· Options
- Enhance coil resistance capabilities for greater reliability.
- Incorporate coil freeze-up safeguards to prevent potential damage.
- Opt for low noise upgrades, ideal for noise-sensitive environments.
- Amplify redundancy to ensure uninterrupted operations and peace of mind.
NEWIN Manufacturing Base

NEWIN FACTORY
Nestled in the vibrant city of Huizhou, Guangdong, our expansive manufacturing base spans an impressive 10,000 square meters, providing a state-of-the-art environment where innovation meets production excellence. This facility is designed to seamlessly blend advanced technology with unparalleled craftsmanship, ensuring every product reflects our high standards.
ISO CERTIFICATION
With prestigious ISO certifications under our belt, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin demonstrates its unwavering commitment to superior quality and sustainable practices. Our certifications are a testament to our dedication to maintaining excellence in every aspect of our operations.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Our cutting-edge Closed Type Cooling Tower Series is engineered for optimal performance, offering a reliable and efficient cooling solution that meets the highest standards of modern engineering.
·
NSH/ NST The highly efficient Open Type Cooling Tower Series is designed for diversified applications, catering to various industrial needs with unparalleled adaptability and efficiency.
·
NTG This robust Industrial Type Cooling Tower Series is tailored for the most demanding environments, providing durable performance that withstands the toughest operational challenges.
·
NECN/NECH Our sophisticated Evaporative Condenser systems deliver superior cooling efficiency, using cutting-edge technology to maximize performance and energy savings.
·
NWFL Introducing innovative Dry Air Cooler solutions that offer high-capacity, energy-efficient performance, redefining expectations for dry cooling systems.
NEWIN provides a comprehensive inventory of premium cooling tower accessories, catering to maintenance and replacement demands across a variety of cooling tower sizes and types. Reach out to us to tailor the precise cooling tower accessories you require. Our extensive range ensures we can meet your specific needs with precision and quality.
CONTAIN:
· Fan drive system components including fan, fan stack, reducer, motor, and shaft, expertly crafted to enhance functionality and ensure seamless operation.
· Water distribution elements such as nozzles and drift eliminators, meticulously designed for optimal fluid management and superior efficiency.
· Heat exchange components like PVC infills and cooling coils, ensuring efficient thermal transfer and maximum cooling performance.
· Additional accessories including air inlet louvers and valves, meticulously engineered for seamless integration into any cooling system.
Packaging & Shipping
Open Type Cooling Towers Shipment: Experience seamless transit with our expertly coordinated shipping solutions, ensuring your equipment arrives on time and in pristine condition. At Newin (Guangdong) Machinery Co., Ltd., we take pride in our unmatched logistics expertise, providing you with peace of mind every step of the way.
Closed Type Cooling Towers Shipment: Discover the assurance of secure and efficient delivery, with our meticulous handling process safeguarding your valuable assets throughout their journey. Our commitment to excellence ensures that your investment is protected and arrives promptly, reflecting our dedication to superior service.
Technical Strength& Standards


Certifications