Product Description
NBDIntroducing the Newin NBD series blade type drift eliminators, meticulously engineered for supreme efficiency across both expansive and mid-sized natural ventilation cooling towers, as well as those with mechanical ventilation. These eliminators are a testament to innovative design, enhancing tower performance like never before. Skillfully designed, these eliminators are experts at capturing and removing a substantial amount of tiny water droplets carried by warm, humid air. This ensures a significant reduction in environmental impact and minimizes water wastage. On installation, they remarkably reduce the water mist escape rate from an original 0.1% to an impressive 0.05%, without altering the cooling water temperature. Each comprehensive set includes detailed components such as eliminator sheets, spacers, PVC rods, and PVC nuts, providing a complete solution for seamless integration.
FEATURES
*A broad selection is available, including V type, S type, M type, multiwave type, along with compatible replacements for other major cooling tower brands, catering to a wide array of operational requirements.
*Crafted with flame-retardant PVC material, with the option of PP material for specialized needs, ensuring durability and safety standards are met across all applications.
*Engineered for anti-aging properties, these eliminators offer high water absorption, low resistance to airflow, outstanding strength, ease of installation, and a longer lifespan, providing reliability and excellence at every step.
*Installation is simplified thanks to the inclusion of rods and screws, facilitating a hassle-free setup process that saves time and effort.
Parameter
PROPERTIES
Elevate your solutions with the adaptable NBD Drift Eliminators! No matter if you need personalized dimensions, unique materials, or distinct thicknesses, Newin (Guangdong) Machinery Co., Ltd. stands as your dedicated ally, poised to fulfill all your detailed demands with exceptional accuracy. Our drift eliminators are also available in specialized flame retardant and anti-bacterial options, perfectly catering to niche requirements. Connect with us with your detailed specifications, and we promise to provide the ideal solution and competitive offer tailored to your specific needs.
Module Length (Max) |
mm |
2000 |
Module Width (Max) |
mm |
500 / 1000 |
Module Depth |
mm |
160 / 175 /200 / 220 |
Flute Height |
mm |
25/45/50 |
Flute Corrugation Angle |
degrees |
- |
Sheet Thickness - Before Forming |
mm |
0.8 |
Sheet Thickness - After Forming |
mm |
0.6 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - PP. |
°C |
95 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
At Newin, we surpass expectations by delivering detailed structure and installation drawings, alongside jobsite storage guidance and a comprehensive quality control report included with each shipment. This ensures our customers are thoroughly prepared the moment they receive their materials. Furthermore, we extend OEM services and unique mold designs upon request, ensuring a tailor-made fit for any project requirements.
Application
APPLICATION & USAGE DETAILS
The Newin NBD Blade Drift Eliminator is expertly designed for counter flow industrial cooling towers, ensuring peak performance and efficiency.Meticulously tested under the esteemed SGS certification and strictly adhering to ASTM Standards, our high-quality drift eliminator promises unrivaled efficiency for your cooling tower operations. Share your tower model or specific dimensions with us, and our team of specialists will precisely calculate the exact number of sheets necessary for a flawless and seamless replacement, ensuring your system remains at the pinnacle of performance.
ADHERENCE TO COMMERCIAL STANDARDS
Our sheet materials are subjected to rigorous and comprehensive testing in strict compliance with SGS and ASTM standards. Upon request, we provide a detailed property evaluation to guarantee superior quality management of your products, affirming our commitment to excellence and reliability.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material. |
ESSENTIAL DATA FOR CELLULAR DRIFT ELIMINATOR REPLACEMENT
For any maintenance or repair needs concerning your cooling tower, provide the detailed measurement data outlined below. With Newin, you are assured of unmatched quality and reliability, complete with personalized site visits or expert maintenance services. Our solutions are engineered to integrate seamlessly with your cooling tower fills or components, ensuring continuity in excellence and operational efficiency.
NEWIN Manufacturing Base

Embark on a Journey through the Impressive NEWIN FACTORY
Strategically nestled in the bustling heart of Huizhou, Guangdong, our expansive manufacturing base spans an impressive 10,000 square meters, serving as a dynamic hub of groundbreaking innovation.
ISO CERTIFICATION - A Resounding Standard of Excellence
Proudly distinguished with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, we radiate an unwavering commitment to unrivaled quality standards and sustainable practices.
WORKSHOPS - Epicenters of Mastery and Innovation
Cutting-edge Welding Workshop: Experience the fusion of precision and innovation, embedded in every weld we meticulously craft.
Advanced Filler Thermoforming Workshop: Where cutting-edge techniques converge with unmatched craftsmanship, yielding extraordinary results.
Precision Sheet Metal Processing Workshop: Elevating the art of metalwork with unparalleled precision and finesse.
Cooling Tower Assembly Workshop: Excellence carefully assembled, piece by piece, to ensure superior operational performance.
TESTING - Unmatched Quality Assurance
Independent Testing LAB: Guaranteeing product reliability and superior performance through rigorous testing protocols.

NEWIN COOLING TOWERS: Efficiency Redefined with Masterful Engineering
· NWN/ NWF/ NCFN: Dive into our Pioneering Closed Type Cooling Tower Series. Revolutionary Closed Type Cooling Tower Series: Expertly crafted for supreme efficiency and unwavering reliability across diverse applications.
· NSH/ NST: Uncover our Cutting-edge Open Type Cooling Tower Series. Groundbreaking Open Type Cooling Tower Series: Harmoniously blending stunning design with functionality for unmatched cooling performance.
· NTG: Reveal our Sturdy Industrial Type Cooling Tower Series. Sturdy Industrial Type Cooling Tower Series: Crafted to excel and withstand the most challenging environments.
· NECN/NECH: Discover our State-of-the-art Evaporative Condenser. State-of-the-art Evaporative Condenser: Precisely engineered to ensure peak cooling efficiency and performance.
· NWFL: Unveil our High-performance Dry Air Cooler. High-performance Dry Air Cooler: Delivering exceptional cooling power complemented by an energy-efficient design for optimal performance.

NEWIN is your reliable partner, offering an extensive range of essential cooling tower accessories. We meticulously attend to the maintenance and replacement needs of each unique cooling tower, regardless of its size or type. Connect with us for bespoke solutions tailored to your precise accessory requirements.
CONTAIN: All-encompassing Cooling Solutions for Every Demand
· Comprehensive Fan drive system: Includes fan, fan stack, reducer, motor, shaft, etc., masterfully engineered for peak performance.
· Efficient Water distribution components: Comprising nozzles, drift eliminator, etc., skillfully designed for superior water management.
· Superior Heat exchange elements: Featuring high-grade PVC infills, cooling coil, etc., effortlessly enhancing thermal efficiency.
· Diverse Other accessories: Air inlet louver, valve, etc., elevating the overall functionality and superior efficiency of your cooling tower.
Packaging & Shipping
Open type cooling towers shipment: Unleash the ultimate in shipping excellence with our expertly crafted solutions, uniquely designed for the demanding needs of open-type cooling towers. Revel in the unmatched consistency and timeliness of our service as we deliver your vital industrial cooling components with unparalleled exactness. Our commitment to reliability not only grants you invaluable peace of mind but also strengthens your path to operational triumph.

Closed type cooling towers shipment: Elevate your industrial prowess with our flawlessly executed logistics solutions for closed-type cooling towers. We pledge a delivery experience that is not only remarkably safe but also impressively prompt and exceptionally secure. Our approach significantly reduces potential downtime, ensuring your operations remain fluid and uninterrupted. This allows you to channel your energies towards driving your business's peak performance and propelling its growth to new heights.

Technical Strength& Standards


Certifications