Product Description
NBDThe Newin NBD series blade type drift eliminators are meticulously engineered to deliver exemplary performance, seamlessly integrating into large and medium-sized natural ventilation cooling towers, as well as mechanical ventilation cooling towers. Crafted with precision, these eliminators stand out as a symbol of efficiency and innovation. Masterfully designed to proficiently capture and remove an impressive volume of tiny water droplets carried by the hot, humid air, these eliminators significantly diminish environmental impact and curtail water loss. Upon installation, enjoy a dramatic reduction in water mist escape rate from a notable 0.1% without the device to an outstanding 0.05%, while maintaining the cooling water temperature with ease. Each comprehensive set includes meticulously crafted eliminator sheets, durable spacers, robust PVC rods, and reliable PVC nuts, ensuring total efficiency.
FEATURES
*Presenting a versatile array, featuring V type, S type, M type, multiwave type, and compatible replacements for other leading brand cooling towers, catering to a wide spectrum of operational requirements.
*Expertly constructed from flame-retardant PVC material, with an optional PP material available for specialized applications, guaranteeing both resilience and safety.
*Ingeniously designed to resist aging, these eliminators exhibit high water absorption, minimal airflow resistance, and exceptional strength, paired with effortless installation and an impressive longevity.
*Streamlines the installation process with the inclusion of rods and screws, promising a smooth and effortless setup experience.
Parameter
PROPERTIES
Elevate your cooling tower's efficiency with Newin's adaptable NBD Drift Eliminators! We specialize in crafting solutions tailored to your precise needs. Need unique dimensions, specific materials, or exact thicknesses? Newin is your dependable ally, poised to fulfill every detail with exactitude. Our drift eliminators are offered in flame retardant and anti-bacterial variations, addressing even the most specialized requirements. Contact us with your specifications, and we'll deliver the ideal solution and proposal tailored just for you.
Module Length (Max) |
mm |
2000 |
Module Width (Max) |
mm |
500 / 1000 |
Module Depth |
mm |
160 / 175 /200 / 220 |
Flute Height |
mm |
25/45/50 |
Flute Corrugation Angle |
degrees |
- |
Sheet Thickness - Before Forming |
mm |
0.8 |
Sheet Thickness - After Forming |
mm |
0.6 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - PP. |
°C |
95 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
Newin goes above and beyond by offering detailed structure and installation drawings, along with jobsite storage guidance and a quality control report with every shipment. This ensures you're fully equipped when your materials arrive. Plus, we provide OEM services and custom mold designs upon request, promising a perfect fit for any project.
Application
APPLICATION & USAGE DETAILS
The Newin NBD Blade Drift Eliminator is a pinnacle of engineering brilliance, crafted specifically for enhancing the performance and efficiency of counter flow industrial cooling towers. This ensures optimal functionality and remarkable efficiency.Tested with precision under the esteemed SGS certification and in full compliance with ASTM Standards, our superior drift eliminator is your guarantee for maximizing efficiency in cooling towers. Provide your tower's model or precise dimensions, and our experienced specialists will methodically determine the exact number of sheets needed for a flawless replacement.
ADHERENCE TO COMMERCIAL STANDARDS
Our sheet materials are subjected to exhaustive testing, faithfully adhering to both SGS and ASTM standards. A detailed property evaluation is available upon request, ensuring unmatched quality management tailored to your product's needs.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material. |
ESSENTIAL DATA FOR CELLULAR DRIFT ELIMINATOR REPLACEMENT
Submit the comprehensive measurement details below for all maintenance or repair requirements for your cooling tower. Opt for Newin and experience unrivaled quality and reliability, accompanied by bespoke site visits or maintenance services designed to integrate seamlessly with your cooling tower components.
NEWIN Manufacturing Base

Explore the Impressive NEWIN FACTORY
Strategically nestled in the thriving heart of Huizhou, Guangdong, our expansive manufacturing base stretches over a remarkable 10,000 square meters, serving as a powerhouse of innovation and cutting-edge technology.
ISO CERTIFICATION - A Resounding Mark of Quality
Proudly adorned with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, our unwavering dedication to unrivaled quality and sustainable practices shines brightly, setting NEWIN apart in the industry.
WORKSHOPS - Centers of Excellence and Innovation
State-of-the-art Welding Workshop: Witness the mastery of precision and innovation infused into every weld we create, ensuring durability and excellence.
Advanced Filler Thermoforming Workshop: Where the finest cutting-edge techniques meet unparalleled craftsmanship, producing exceptional results that redefine industry standards.
Precision Sheet Metal Processing Workshop: Perfecting the art of metalwork with unmatched accuracy and finesse, delivering products of exceptional quality.
Cooling Tower Assembly Workshop: Excellence assembled, meticulously piece by piece, to ensure superior performance and reliability in every design.
TESTING - Unparalleled Quality Assurance
Independent Testing LAB: Ensuring product reliability and exceptional performance through stringent testing protocols, guaranteeing customer satisfaction.

NEWIN COOLING TOWERS: Efficiency Masterfully Redefined
· NWN/ NWF/ NCFN: Experience our Cutting-edge Closed Type Cooling Tower Series. Cutting-edge Closed Type Cooling Tower Series: Meticulously engineered for optimal efficiency and unmatched reliability in diverse applications, setting new benchmarks in cooling technology.
· NSH/ NST: Discover our Innovative Open Type Cooling Tower Series. Innovative Open Type Cooling Tower Series: Seamlessly merging exquisite design and functionality for superior cooling performance, offering unparalleled advantages.
· NTG: Unveil our Robust Industrial Type Cooling Tower Series. Robust Industrial Type Cooling Tower Series: Engineered to excel and endure in even the most demanding environments, ensuring longevity and efficiency.
· NECN/NECH: Explore our Efficient Evaporative Condenser. Efficient Evaporative Condenser: Precision-engineered to deliver maximum cooling efficiency and performance, meeting the highest industry standards.
· NWFL: Discover our High-performance Dry Air Cooler. High-performance Dry Air Cooler: Offering exceptional cooling power paired with an energy-saving design for optimal efficiency and reduced operational costs.

NEWIN stands as your trusted partner, offering a comprehensive range of essential cooling tower accessories. We meticulously cater to the maintenance and replacement needs of every cooling tower, regardless of its size or type. Reach out to us for bespoke solutions tailored precisely to your specific accessory requirements, ensuring seamless integration and performance.
CONTAIN: Comprehensive Cooling Solutions for Every Need
· Comprehensive Fan drive system: Comprising fan, fan stack, reducer, motor, shaft, etc., meticulously engineered for pinnacle performance, enhancing the overall efficiency of your operations.
· Efficient Water distribution components: Including nozzles, drift eliminator, etc., expertly designed for superior water management, maximizing cooling tower efficacy.
· Superior Heat exchange elements: Featuring high-quality PVC infills, cooling coil, etc., to enhance thermal efficiency effortlessly, paving the way for energy conservation.
· Diverse Other accessories: Air inlet louver, valve, etc., enhancing the overall functionality and superior efficiency of your cooling tower, ensuring optimal operational performance.
Packaging & Shipping
Open type cooling towers shipment: Elevate your shipping experience to new heights with our exceptional and precise shipping services, expertly crafted for open-type cooling towers. Enjoy the confidence that comes with our reliable, timely deliveries, as we seamlessly transport your vital industrial cooling solutions. Rest easy knowing your operations are supported by punctuality and precision, reinforcing your path to operational excellence.

Closed type cooling towers shipment: Maximize the efficiency of your industrial cooling capabilities with our skillfully coordinated logistics for closed-type cooling towers. We ensure a delivery process that is not only swift and secure but also incredibly safe, drastically reducing downtime. This empowers you to focus on your core business operations, driving optimal performance and fostering significant growth in your business endeavours.

Technical Strength& Standards


Certifications