Introducing the CTI Certified Cross Flow Open Type Cooling Tower NST Series from Newin (Guangdong) Machinery Co., Ltd. Experience unparalleled efficiency and cutting-edge design with our top-tier cooling solutions, renowned for their exceptional performance and CTI certification. Elevate your cooling systems with the NST Series, where innovation meets reliability.
Product Description
NST The NST series boasts an advanced cross-flow design, a state-of-the-art induced draft open-loop cooling tower. Perfectly crafted for small to medium industrial applications, it integrates seamlessly with air-conditioning and mechanical ventilation systems. Its versatility also extends to projects with less stringent water quality demands.
FEATURES
CTI Certified, Performance Ensurance
> High Efficiency Cooling
- Features a dual-sided, fully opened air intake to ensure complete air immersion.
- Equipped with expansive infill areas, markedly boosting the heat exchange efficiency.
- Incorporates high-frequency transverse water flow, promoting vigorous turbulence for superior cooling efficiency.
> Maximise Resource Utilization
- Innovatively minimizes water wastage while enhancing ventilation to significantly cut down energy consumption.
- Predominantly constructed from recyclable materials, reinforcing our commitment to environmental sustainability.
> High Impact Resistant
- Infills and internal framework are meticulously engineered for rigidity, ensuring resilience against impacts and preventing infill damage and blockage.
> Ease to Operate & Maintain
- Main structure is fortified with corrosion-resistant properties, guaranteeing easy operation, straightforward maintenance, and reduced operational costs.
MAIN PARTS
1. High Efficiency Axial Fan
> Features a renowned aluminum alloy axial fan, achieving high performance, reduced power consumption, and minimal noise.
> Enhanced with superior quality V-belt and pulley, ensuring stable operation and simplified maintenance.
> Includes a TEFC cooling tower duty motor, with optional gear reducer available. Choose from two-speed, variable speed, or explosion-proof motors.
> Upgrade to a Permanent magnetic direct drive system for lower power consumption, achieving energy efficiency ratings up to IE5.
2. Uniform Water Distribution System
> Facilitates uniform water distribution through gravity.
> Equipped with large diameter, non-clogging PP nozzles offering extensive spraying coverage.
> Comes with a removable steel cover, simplifying checks and maintenance.
> Optional high-low flowrate nozzles ensure uniform water distribution even at reduced flowrates.
3. Integrated Baffle Type Infill
> Crafted with high-quality self-extinguishing PVC infill.
> Integrally formed infill and drift eliminator, enhancing heat exchange performance while keeping drift loss below 0.005%.
> Options available for high or low-temperature resistant infill to meet special operational conditions.
4. Cold Water Basin
> Features an automatic makeup water system using a corrosion-resistant stainless-steel mechanical float valve, offering high flexibility.
> Option to install a water basin heater for frost protection during cold seasons.
5. Heavy Duty & High Stability Structure
> Constructed from Z700 HDGS corrosion-resistant material, secured with 304 Stainless Steel bolts and nuts for unmatched robustness and stability.
> Optional materials include 304 / 316 Stainless Steel or NWN-Armour, catering to specific requirements.
6. SMC Compressed Moulded
> Made from fiberglass material, providing corrosion and UV resistance.
> Optimizes airflow uniformity within the tower, reducing airflow resistance for efficient fan operation.
7. High Quality Fiberglass Panel
> Composed of fiberglass material, ensuring resistance to corrosion and UV damage.
> Embrace the innovative corrugated design, meticulously crafted to amplify durability, ensuring the cooling tower's service life is remarkably extended.
> Choose with confidence from our selection of premium materials: robust 304/316 Stainless Steel or the resilient NWN-Armour, tailored to meet your specific needs.
8. Access Door
> Designed for your convenience, our access door simplifies the process of tower inspection and maintenance, providing hassle-free entry.
9. Maintenance Platform
> Our state-of-the-art double layer maintenance platform revolutionizes internal cooling tower upkeep, offering unparalleled safety and ease, especially during fan service operations.
10. Cage Ladder & Handrail
Product Parameters
Tower Model |
Outline dimensions (mm) |
Weight (Kg) |
NST |
W |
L |
H |
Dry |
Wet |
NST-18-A15-2A11-C1 |
3310 |
1800 |
3500 |
1030 |
2480 |
NST-20-B15-2A12-C1 |
3310 |
2000 |
3700 |
1110 |
2730 |
NST-26-D18-3A14-C1 |
4080 |
2600 |
4110 |
1660 |
4130 |
NST-30-D21-3A16-C1 |
4220 |
3000 |
4540 |
1890 |
4860 |
NST-33-E24-3A17-C1 |
4540 |
3300 |
4790 |
2080 |
5520 |
NST-35-F26-4A17-C1 |
5350 |
3500 |
4890 |
2960 |
8290 |
NST-40-F30-4B17-C1 |
5750 |
4000 |
4940 |
3310 |
9690 |
NST-43-G32-4B18-C1 |
5950 |
4300 |
5140 |
3550 |
10620 |
NST-46-H34-4B20-C1 |
6150 |
4600 |
5560 |
3900 |
11740 |
NST-48-H40-5B18-C1 |
7420 |
4800 |
5390 |
4560 |
13970 |
NST-50-I42-5B20-C1 |
7560 |
5000 |
5610 |
5190 |
15280 |
NST-54-J42-5B22-C1 |
7560 |
5400 |
6010 |
5650 |
16690 |
NST-60-J47-5B22-C1 |
8040 |
6000 |
6210 |
6330 |
19120 |
Explore the Advanced NST Series FRP Cooling Tower Solutions, meticulously crafted to adapt seamlessly to diverse working conditions.
OPTIONS
Innovative Permanent Magnetic Direct-Driven Fan System
Revolutionary Energy Saving Design
> Experience the future with variable frequency control, enabling seamless low-speed operation, exceptional efficiency, and superior power factor.
> Experience the convenience of a direct-driven fan system-no transmission losses, zero maintenance hassle.
> Achieve unprecedented energy efficiency with ratings up to IE5, delivering substantial power savings and enhancing energy conservation.
NWN-Armour Advanced Corrosion Resistant Technology
Innovative Corrosion Resistant Design
Featuring a galvanized steel panel enhanced with the constantly evolving NWN-Armour anti-corrosion coating. This offers corrosion resistance comparable to Stainless Steel, providing a cost-efficient alternative.
Additional Accessories
Comprehensive Accessories: PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction solutions.
NEWIN Manufacturing Base
Discover Excellence at the NEWIN FACTORY
Our State-of-the-Art Manufacturing Facility is Located in the Bustling City of Huizhou, Guangdong. It Spans an Impressive 10,000 Square Meters, Equipped to Meet All Your Cooling Tower Needs.
Proudly Holding ISO CERTIFICATION
We are Accredited with ISO9001:2015 for our Superior Quality Management System and ISO14001:2015 for Our Commitment to an Environmentally Sustainable Management Process.
Dedicated and Specialized WORKSHOPS
Expertise in Action: Visit Our Welding Workshop
Precision Crafting at our Filler Thermoforming Workshop
Advanced Techniques in the Sheet Metal Processing Workshop
Assembly Excellence: Cooling Tower Assembly Workshop
Rigorous TESTING for Unmatched Quality
Cutting-Edge Independent Testing LAB to Ensure Excellence
Explore the Versatility of NEWIN COOLING TOWERS:
·
Innovative NWN/ NWF/ NCFN Our Exclusive Closed Type Cooling Tower Series
·
Reliable NSH/ NST Our Open Type Cooling Tower Series, Renowned for Efficiency
·
Robust NTG Industrial Type Cooling Tower Series, Built for the Toughest Demands
·
Cutting-Edge NECN/NECH High-Efficiency Evaporative Condenser
·
Innovative NWFL Advanced Dry Air Cooler for Optimal Performance
NEWIN is your Go-To for Comprehensive Cooling Tower Accessories. We Stock Extensive Components to Support Maintenance and Replacement for Any Cooling Tower Model. Reach Out to Us for Customized Accessory Solutions.
OFFERINGS INCLUDE:
· Comprehensive Fan Drive System (Including fan, fan stack, reducer, motor, shaft, and more)
· Efficient Water Distribution Systems (Featuring nozzles, drift eliminator, etc.)
· Exceptional Heat Exchange Components (Such as PVC infills and cooling coil)
· A Range of Other Accessories (Including air inlet louver, valve, and more)
Packaging & Shipping
Open Type Cooling Towers Shipment: Our CTI Certified Open Type Cooling Towers are dispatched with the utmost care, ensuring timely delivery and impeccable condition upon arrival. We prioritize efficiency in our logistics to meet your cooling needs without delay.
Closed Type Cooling Towers Shipment: Experience seamless delivery of our Closed Type Cooling Towers, expertly packaged and swiftly shipped to preserve quality and performance. Our commitment is to safeguard your investment with a reliable and efficient shipping process.
Technical Strength& Standards
Certifications